Clinical Trials Logo

Clinical Trial Summary

The shoulder joint in the human body has a broader range of motion and opening compared to other joints, resulting in a multitude of potential problems. The rotator cuff lesion is one such issue. The rotator cuff is found in the subacromial space of the shoulder and results from the compression of the subacromial bursa and the long head of the M.biceps muscle between the humerus and the coracoacromial arch. Upon reviewing the literature, therapeutic exercise and electrotherapy modalities are the most preferred and studied areas. Alongside these, we also observe the usage of Mulligan and Maitland techniques for the treatment of rotator cuff lesions. The Mulligan technique was developed by Brian Mulligan in 1980, who lent his name to it. Also known as mobilization with movement, this technique is often applied to the body's distal joints. The Maitland mobilization technique is used to treat the relevant joint with specific methods, particularly focusing on pain and stiffness in the joint. The technique's application is graded from 1 to 4. Grade 1 is a small oscillation created without loading throughout the joint movement. Grade 2 is performed with a slightly more oscillation from the beginning of the movement. Grades 1 and 2 aim to restrict the pain stimulus going to the central nervous system by stimulating the mechanoreceptor in the joint, thereby reducing the sensation of pain. Grade 3 is applied at a larger amplitude until a limitation is felt from the middle of the joint movement. Lastly, grade 4 is applied to the limited small amplitude until tissue resistance is felt. Grades 3 and 4 are used to alleviate joint stiffness by applying shorter oscillation stimuli to a shorter tissue. The results of the use of Mulligan and Maitland techniques have been demonstrated in different studies in the literature. However, as far as we know, no study in the literature compares these two techniques in individuals with rotator cuff lesions. Based on this gap in the literature, the purpose of this study is to investigate the effects of the Mulligan technique and the Maitland method on pain, range of joint motion, functionality, joint position sense, and quality of life in individuals with a rotator cuff problem.


Clinical Trial Description

The aim of this study is to examine the effectiveness of the Mulligan and Maitland techniques on pain, range of joint motion, functionality, joint position sense, and quality of life in individuals diagnosed with rotator cuff lesions. Individuals diagnosed with a rotator cuff lesion and admitted to Medipol University Hospital will be included in the study. Participants will be randomly divided into three groups. A conventional treatment program will be applied to individuals in all three groups five days a week for three weeks. The first group will only receive conventional treatment. The second group will receive conventional treatment plus the Mulligan technique. The third group will receive conventional treatment plus the Maitland technique. The conventional treatment program will be applied to all participants included in the study, consisting of wand, codman, active and passive stretching exercises, and TENS. This program will be administered to all patients five days a week. Wand exercises will be applied in the directions of flexion, abduction, extension, internal and external rotation, and will consist of 10 repetitions. Codman exercises will be applied in the directions of flexion, abduction, and circular, and will also consist of 10 repetitions. Active and passive stretching exercises will be applied in the directions of flexion, abduction, and external rotation, and will consist of 10 repetitions. TENS application will be administered for 20 minutes at 100Hz. All these exercises will be applied to the control, Mulligan, and Maitland groups. Mulligan Group: The mobilization with movement technique, a part of Mulligan applications, will be performed twice a week in the directions of flexion, abduction, and external rotation. Maitland Group: The Maitland application will be applied in the anterior-posterior, posterior-anterior, and caudal directions. The Maitland application will be administered at grades 2-3. Patients in this group will receive the application in five sets of 30 seconds, twice a week. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05924360
Study type Interventional
Source Istanbul Medipol University Hospital
Contact
Status Completed
Phase N/A
Start date June 23, 2023
Completion date August 26, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT04974242 - Physiotherapy for Patients Awaiting Rotator Cuff Repair N/A
Recruiting NCT06055478 - Effect of Suprascapular Nerve Block and Axillary Nerve Block After Arthroscopic Rotator Cuff Repair N/A
Completed NCT04552925 - Exercises With Electromyographic Biofeedback in Conservative Treatment of Massive Rotator Cuff Tears N/A
Not yet recruiting NCT04047745 - Post-operative Exparel Study Following Rotator Cuff Repair N/A
Completed NCT01029574 - Platelet Rich Plasma on Rotator Cuff Repair Phase 3
Not yet recruiting NCT05817578 - Profiling the RCRSP Patient: a Pain Phenotype Classification Algorithm
Not yet recruiting NCT05670080 - Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair? N/A
Suspended NCT04421417 - The Effect of Microfracture Procedure on Rotator Cuff Tendon Healing N/A
Recruiting NCT06156423 - Investigation of the Effect of Motor Control Exercises in Patients Undergoing Rotator Cuff Surgery N/A
Completed NCT06145815 - Machine Learning Predictive Model for Rotator Cuff Repair Failure
Not yet recruiting NCT05009498 - Vitamin D3 Supplementation for Vitamin D Deficiency in Rotator Cuff Repair Surgery N/A
Completed NCT04594408 - Tranexamic Acid to Improve Arthroscopic Visualization in Shoulder Surgery Phase 4
Terminated NCT04855968 - The Effect of Mindfulness/Meditation on Post-operative Pain and Opioid Consumption N/A
Not yet recruiting NCT04538001 - Safety and Efficacy of Rotator Cuff Function Restoration Balloon in Irreparable Rotator Cuff Tear N/A
Completed NCT04710966 - Comparison Between Arthroscopic Debridement and Repair for Partial-thickness Rotator Cuff Tears N/A
Recruiting NCT06192459 - Effect of the Muscle Strength and Range of Motion Training for Post-platelet Rich Plasma Injection in People With Rotator Cuff Partial Tear N/A
Recruiting NCT05925881 - Lower Trapezius Transfer vs Bridging Reconstruction N/A
Recruiting NCT05988541 - Rotator Cuff Integrity and Clinical Outcomes 5 Years After Repair. N/A
Not yet recruiting NCT04584476 - Superior Capsular Reconstruction Versus. Partial Repair for Irreparable Rotator Cuff Tears N/A
Not yet recruiting NCT04587037 - A Clinical Study Comparing Superior Capsule Reconstruction Using Different Graft for Irreparable Rotator Cuff Tear N/A