Glaucoma Clinical Trial
Official title:
Assessment of Visual Function in Ophthalmic Disorders Using Virtual Visual Field Analysis
1. To evaluate the accuracy of virtual visual field (VVF) headsets equipped the standard visual field software in its ability to assess visual function in various retinal, glaucoma and neuro-ophthalmic disorders by comparing retinal fundus and optic nerve images, optical coherence tomography and neuroimages to the VVF produced. 2. To test the null hypothesis that VVF testing compares favorably to the gold standard, Humphrey visual field (HVF) by comparing testing time, mean sensitivity, markers of reliability including false positives and negatives and fixation losses and global indices such as mean deviation and pattern standard deviation.
1. Study Style: Prospective, Controlled Clinical Trial 2. Objectives: 1. To determine the capacity for a portable head-mounted virtual visual field-testing device, with capacity for remote testing, to accurately analyze visual function in various retina, neuro-ophthalmic and glaucoma disorders. 2. To compare virtual visual field results with the "gold standard," Humphrey visual fields. 3. Subjects: Consecutive patients already scheduled for visual fields for various retina, glaucoma and neuro-ophthalmic conditions and normal controls. SETTING AND PROTOCOL FOR HUMAN RESEARCH: 1. Location: Ophthalmology Department, Jacobi Medical Center, Bronx New York. 2. Recruitment: Patients already presenting to the eye clinic or seen on the wards at Jacobi Medical Center will be offered a chance to participate as volunteers. No other active recruitment will be done. 3. Retention and Dropout: Investigators will encourage patients to complete their testing. However, it will be made clear that they can drop out at any time without need to provide a reason. Dropouts will be replaced with other consenting patients. 4. Protocol (Interventions and Timing): 1. Consecutive patients presenting to the Jacobi eye clinic and wards who are diagnosed with neurologic, glaucoma and retina conditions and already are scheduled to have Humphrey visual field analysis, will be asked if they would like to voluntarily participate in this study. 2. Interested patients will be have the study explained to them and an informed consent taken by the study resident/technician. 3. The standard Humphrey visual field (HVF) will be conducted by the technician (5-10 minutes) in the usual manner. 4. The option of doing the virtual fields immediately, on the same day, will be offered vs returning to conduct the test within 3 months. 5. The virtual reality headset will be applied and instructions in the patient's preferred language provided through the earpiece of the virtual visual field (VVF). When the patient indicates they wish to proceed, the test will be started by the technician. 6. The technician is already versed in conducting both versions of the visual field tests. 5. Clinical Analysis: All fields will be stored digitally within each Health Insurance Portability and Accountability Act (HIPAA) compliant device-specific website for later analyses by respective Attendings (glaucoma, retina and neuro-ophthalmology/neurology). 6. Data Collection: 1. The patients' demographic details, visual field pattern deviation, and global indices (mean deviation, f and pattern standard deviation) and reliability indices (fixation losses, false positives/negatives will be documented in the data collection Excel sheet. 2. Supporting ancillary tests (optical coherence tomography, retina photography and neuroimaging) will be collected for each patient and reported findings documented. These tests are part of normal standard of care assessment of patients at Jacobi Medical Center. STUDY POPULATION: 1. Consecutive clinic and ward patients (>18yrs old) with glaucoma, retinal or neurological disorders able to understand, consent and deemed physically able to perform the visual field tests. 2. Power Calculation: 1. Alpha 0.05 2. Power 80% 3. Using the findings of mean deviation (MD) in perception of light from a previous VVF glaucoma study : mean (SD)=-3.78 (7.49) dB units in glaucoma patients and 0.587 (2.588) dB in the controls. 4. 39 patients and 39 controls in each sub-population (retina, glaucoma and neuro-ophthalmology) will be required to sufficiently power the study. Round numbers of 40 cases and 40 controls for each study to be sufficiently powered. For all three studies, 120 study cases in total will be tested with clinical conditions and 120 normal cases as normal controls. 240 cases in total will be tested.There will be confounding variables that can be addressed with subgroup analysis or multivariate regression analysis. INFORMED CONSENT: 1. The informed consent to participate in the study will be taken at the site of testing at Jacobi Medical Center. 2. The informed consent will be taken by one of the study residents or the study technician. STATISTICAL ANALYSIS: Excel and SAS (Statistical Analysis Software, SAS institute Inc. Cary, North Carolina, USA) software will be used for descriptive assessment and statistical analysis of the data set and generation of graphs. 1. Data will be used to test the hypothesis that the virtual visual field headset is able to accurately detect visual field defects in ophthalmic conditions and develops visual field maps and global indices that compare favorably with the gold standard, Humphrey visual fields. 2. Interim analyses will be conducted for each sub-population (glaucoma, retina, neurology) when they reach the power number ~40. 3. Once all data is de-identified, it will be analyzed using SAS software. 4. Descriptive data will be determined with basic percentages. 5. Aggregate means of global indices of each study group: retina disorders, glaucoma of all stages (1-mild; 2-moderate; 3-severe; 4-indeterminate) and neuro-ophthalmic conditions, will be compared with their control group and VVF compared to HVFusing t-test, Chi-square, Mann-Whitney and Kruskal-Wallis tests. 6. Correlation between the parameters of virtual visual field test and Humphrey visual field including time for test, mean sensitivity (MS, expressed in decibels), fixation loss (FL), false negative (FN), false positive (FP), mean deviation (MD) and pattern standard deviation (PSD) will be assessed using linear regression models that will account for confounding variables such as age, visual acuity and other ocular conditions. 7. Statistical significance will be set at p<0.05. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06000865 -
Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE
|
N/A | |
Recruiting |
NCT06278597 -
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03274024 -
The Asia Primary Tube Versus Trab (TVT) Study
|
N/A | |
Completed |
NCT04552964 -
Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma
|
N/A | |
Recruiting |
NCT01957267 -
Functional and Structural Imaging for Glaucoma
|
||
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Completed |
NCT04020705 -
The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma
|
N/A | |
Completed |
NCT03150160 -
Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma
|
Phase 4 | |
Not yet recruiting |
NCT05581498 -
Glaucoma Exercise as Medicine Study (GEMS).
|
N/A | |
Recruiting |
NCT02921568 -
Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes
|
N/A | |
Active, not recruiting |
NCT02901730 -
Clinical Study of LPI With Different Laser Wavelengths
|
N/A | |
Completed |
NCT02955849 -
A Trial of China Laser and Surgery Study Glaucoma in Rural China
|
Early Phase 1 | |
Recruiting |
NCT02471105 -
Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml
|
Phase 4 | |
Recruiting |
NCT02554214 -
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
|
N/A | |
Active, not recruiting |
NCT02390284 -
Stop Retinal Ganglion Cell Dysfunction Study
|
Phase 3 | |
Completed |
NCT02520674 -
Glaucoma Screening With Smartphone Ophthalmology
|
N/A | |
Completed |
NCT02628223 -
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
|
N/A | |
Completed |
NCT02653963 -
Triamcinolone for Ahmed Glaucoma Valve
|
N/A | |
Completed |
NCT02390245 -
Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study
|
N/A |