Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03592017
Other study ID # 13703
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date October 1, 2018
Est. completion date July 30, 2022

Study information

Verified date July 2021
Source Oxford University Hospitals NHS Trust
Contact Peter Charbel Issa, DPhil, MD
Phone +44 1865 234737
Email study-enquiry@outlook.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Fundus autofluorescence imaging has become an important diagnostic tool in ophthalmology, guiding diagnosis and assessment of progression of retinal diseases. This study investigates the performance of optimized long-wavelength autofluorescence imaging. To achieve this goal, the investigators will determine an optimal long wavelength excitation light and investigate the autofluorescence signal intensity in normals and patients with different retinal diseases. The diagnostic performance of the long-wavelength autofluorescence will be evaluated by assessing sensitivity and specificity for diagnosing a variety of degenerative retinal diseases and by comparing it to conventional autofluorescence.


Description:

Fundus autofluorescence (AF) imaging of the retina with confocal scanning laser ophthalmoscopy has been established as a non-invasive imaging modality for the diagnosis of retinal and macular diseases. Long-wavelength near-infrared autofluorescence (excitation: 787 nm, LW-AF) is a new, innovative alternative to the classic autofluorescence imaging using 488 nm blue excitation light. Excitation of the fluorophores at the ocular fundus using a longer wavelength has several advantages. However, with the current imaging technique the autofluorescence signal and thus image quality is considerably lower compared to conventional short-wavelength autofluorescence (SW-AF). This may be the main reason for the currently limited application and scarce scientific publications on this technique. Therefore, the objective of this study is to assess the performance of an optimized setup of long-wavelength autofluorescence imaging in clinical routine applications. For this purpose, additional laser sources will be integrated into a scanning laser ophthalmoscope and the performance with regards to image quality will be investigated systematically using different excitation wavelengths and filter combinations in healthy controls. In a next step, the signal intensity will be quantified using an integrated fluorescent reference. First, factors affecting measurements will be identified, followed by generation of a normative database. Subjects with various retinal diseases will then be investigated and compared to the normative database. Finally, the diagnostic performance of long-wavelength autofluorescence imaging to detect retinal degenerative diseases will be investigated and compared to conventional imaging techniques.


Recruitment information / eligibility

Status Recruiting
Enrollment 500
Est. completion date July 30, 2022
Est. primary completion date July 30, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Age 18 years or above - Defined retinal disease (patients) or no known retinal disease (healthy participants) - Participants willing to read and understand the study information and provide informed consent - Participants agree to have some examinations and photographs taken from their eyes Exclusion Criteria: - Significant opacities of the ocular media - difficulties positioning still in front of the camera - any ocular/ general disease known to affect recordings and/or analysis of retinal images - Pupil diameter <5mm

Study Design


Intervention

Device:
Long-wavelength autofluorescence imaging
Long-wavelength autofluorescence imaging will be performed with a prototype confocal scanning laser (cSLO) ophthalmoscope which will be equipped with additional laser sources and a reference for quantification of the signal. The experimental long-wavelength laser sources will be integrated into a custom-modified Spectralis HRA cSLO from Heidelberg Engineering. The additional laser sources will operate with long wavelength which are less energetic compared to the conventional short-wavelength lasers used currently for routine autofluorescence imaging. All safety standards have been considered and the light exposure for all imaging modes is well below the exposure limits for Class 1 and Class1M laser products as defined in the standard IEC 60825-1, edition 3.0, 2014-5.

Locations

Country Name City State
United Kingdom Oxford Eye Hospital Oxford

Sponsors (1)

Lead Sponsor Collaborator
Oxford University Hospitals NHS Trust

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Performance of long-wavelength autofluorescence imaging The sensitivity and specificity to detect characteristics in retinal diseases will be investigated in patients with various retinal diseases and compared to conventional imaging methods 1 day
Secondary Optimization of the signal of long-wavelength autofluorescence imaging using different laser and filter settings To optimize the signal of long-wavelength autofluorescence imaging, the fluorescence intensity of the different laser sources and filter settings will be assessed. 1 day
Secondary Quantification of the optimized signal of long-wavelength autofluorescence imaging in healthy controls and participants with various retinal diseases To quantify the optimized signal of long-wavelength autofluorescence imaging the absolute fluorescence intensity compared to a fluorescent reference will be assessed in patients with various retinal diseases and compared to healthy controls 1 day
See also
  Status Clinical Trial Phase
Recruiting NCT04956237 - Retinal Surgery With or Without Anesthesiologist, Comparison of Surgeon and Patient's Comfort
Recruiting NCT01432847 - Cell Collection to Study Eye Diseases
Active, not recruiting NCT04130841 - Effects of Internal Limiting Membrane Peeling on Visual Function in Epiretinal Membrane Surgery N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Active, not recruiting NCT03872479 - Single Ascending Dose Study in Participants With LCA10 Phase 1/Phase 2
Active, not recruiting NCT04636307 - Characterization of Retinal Disease Progression in Eyes With Non Proliferative Diabetic Retinopathy in Diabetes Type 2 Using Non-invasive Procedures (CHART)
Not yet recruiting NCT06451068 - Peripheral Retina Robotically Aligned OCT Study N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Completed NCT02315170 - Assessment of Novel Intraocular Injection Guide N/A
Completed NCT00069199 - Optical Coherence Tomography Comparative Study N/A
Withdrawn NCT03603990 - Effect of Vitrectomy on the Evolution of Refractory Diabetic Macular Edema N/A
Active, not recruiting NCT04123626 - A Study to Evaluate the Safety and Tolerability of QR-1123 in Subjects With Autosomal Dominant Retinitis Pigmentosa Due to the P23H Mutation in the RHO Gene Phase 1/Phase 2
Withdrawn NCT02445001 - Erythrocyte Ghost Mediated Retinal Diagnosis N/A
Completed NCT01468337 - Topical Interferon Gamma-1b for Central Serous Chorioretinopathy Phase 1/Phase 2
Completed NCT01227993 - Extension Study for the Evaluation of Finasteride in the Treatment of Chronic Central Serous Chorioretinopathy Phase 1/Phase 2
Completed NCT00792259 - Topcon 3D OCT-1000 Optical Coherence Tomography System
Completed NCT00035906 - Research Study in Patients With Persistent Macular Edema Phase 2
Recruiting NCT05158699 - Effectiveness of Periocular Drug Injection in CATaract Surgery Phase 3
Terminated NCT04110015 - Assessment of Visual Function in Ophthalmic Disorders Using Virtual Visual Field Analysis
Recruiting NCT03823092 - Polarization Perception in Health and Disease. Testing a New Sight Test