Clinical Trials Logo

Clinical Trial Summary

Optical coherence tomography (OCT )provides high resolution information regarding the anatomic structure of the tissues of the eye in a cross-sectional and 3 dimensional view. Much of this information is not able to be visualized by a clinician. Utilizing this information during surgery will allow for the ophthalmic surgeons to better understand how surgical procedures impact the anatomic structure of the eye. In this study an OCT device that has been built into the microscope (rather than mounted on the side or held in the surgeon's hand) and will be utilized to take images at various milestones during surgery to assess feasibility and potential utility of this technology. Since it is built into the microscope, there are potential significant advantages over a separate system including increased efficiency, improved working distance, and the ability to visualize tissue-instrument interactions.


Clinical Trial Description

Optical coherence tomography (OCT) has become a critical component to the evaluation of ophthalmic disease. Similar to the ultrasound, OCT uses light to reconstruct an image of the tissue of interest. In effect, OCT functions almost like a light biopsy, allowing clinicians to visualize subtle changes in the tissue, such as macular edema or subretinal fluid. OCT in the clinic setting has become the gold standard for monitoring diseases such as macular degeneration and diabetic retinopathy;and it has become one of the most frequently ordered diagnostic test in ophthalmology. Due to the restraints in the size and structure of the imaging equipment, the use of OCT in the operating room has been limited. More recently, modifications to OCT table-tops models as well as the development of hand-held OCT probes have allowed for the translation of OCT technology into the operating room. The high resolution anatomic information that is gained from the OCT imaging is a natural complement to the ophthalmic surgeon. Using OCT during vitreoretinal surgery has revealed subtle changes in the microarchitecture of the retinal diseases such as retinal detachment, macular hole and optic pit, that were not previously known. Our research team has been examining intraoperative OCT in the operating room using both a handheld and microscope-mounted portable spectral domain OCT probe with excellent success and an outstanding safety record. In this study an OCT device that has been built into the microscope (rather than mounted on the side or held in the surgeon's hand) and will be utilized to take images at various milestones during surgery to assess feasibility and potential utility of this technology. Since it is built into the microscope, there are potential significant advantages over a separate system including increased efficiency, improved working distance, and the ability to visualize tissue-instrument interactions. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02423213
Study type Observational
Source The Cleveland Clinic
Contact Justis P Ehlers, M.D.
Phone 216-636-0183
Email ehlersj@ccf.org
Status Recruiting
Phase
Start date January 2014
Completion date January 2025

See also
  Status Clinical Trial Phase
Completed NCT03332758 - Inflammasomes in Cell Death in FTMH, ERM, and RRD
Completed NCT03660384 - Silicone Oil Versus Gas in PDR Patients Undergoing Vitrectomy N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT04535622 - Efficacy of Exercise Program for Facedown Posture-related Pain After Retinal Surgery N/A
Recruiting NCT05863312 - REtinal Detachment Outcomes Study N/A
Recruiting NCT05561569 - Air Versus Gas Tamponade in Primary Retinal Detachment N/A
Not yet recruiting NCT05538156 - Internal Limiting Membrane Peeling in Retinal Detachment Surgery N/A
Completed NCT03046719 - Subconjunctiva Bupivacaine as Analgesia in Intravitreal Silicone Oil Removal N/A
Recruiting NCT01261533 - Flexibility, Efficacy, and Safety of a Foldable Capsular Vitreous Body in the Treatment of Severe Retinal Detachment Phase 1
Terminated NCT02068625 - Rasagiline (Azilect) - Neuroprotection for Macula-off Retinal Detachment Phase 4
Completed NCT00000140 - The Silicone Study Phase 3
Recruiting NCT05543018 - Effect of Intraocular Tamponade on Visual Perception N/A
Not yet recruiting NCT04518696 - Suprachoroidal Buckling for the Management of Rhegmatogenous Retinal Detachment N/A
Completed NCT03321253 - Changes of Macular Pigment and Parameters of Eyes After YAG Laser Treatment in Cases With Capsule Opacification N/A
Completed NCT06166914 - Efficacy of 5-fluorouracil and Low Molecular Weight Heparin in High-risk Pediatric Retinal Detachment N/A
Enrolling by invitation NCT05566626 - Retinal Oxygenation Estimation Trial With Mantis Photonics Hyperspectral Camera N/A
Not yet recruiting NCT03631108 - Feasibility Study and Preliminary Application Study on Iris OCTA
Recruiting NCT02201706 - Multi-electrocoagulation Retinectomy for Retinal Re-detachment in Silicone Oil Filled Eye N/A
Completed NCT03218371 - Scleral Self-indentation Chandelier-assisted Peripheral Vitrectomy Under Air Rhegmatogenous Retinal Detachment. N/A
Completed NCT00000154 - Diabetic Retinopathy Vitrectomy Study (DRVS) Phase 3