Clinical Trial Summary

Introduction. The increasing use of telephone medical advice requires the development of telemedicine tools to assess the patient's severity. Respiratory rate (RR) is a simple vital parameter and is often associated with morbidity and mortality of patients. There is no standardized measure of RR by telephone. Objective: The investigators wanted to evaluate the RR measurement by phone using a smartphone application called RRate. Methods. Adults who have been admitted for less than 6 hours to the emergency department after calling Center 15 and whose main reason for consultation is dyspnea will be included. Patients with non-invasive or tracheotomized ventilation will be excluded. The main objective will be to compare by Bland-Altman method the accuracy of the RRate measurement by phone to a one-minute RR measurement at patient's bedside. Secondary endpoints will evaluate the length of RR measurement according to the different methods used; measurement failure criteria; the accuracy of different measurement techniques (RRate at patient's bedside, impedancemetry, traditional measurement during 15s or 30s). Expected Results. The accuracy of the RR measurement by RRate over the telephone should be within the limits of agreement. The measurement time should be shorter with the RRate application than with traditional methods. However, the measurement by telephone should not always be feasible in patients with mild dyspnea or with poorly audible breathing.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04077593
Study type Observational [Patient Registry]
Source University Hospital, Grenoble
Contact
Status Completed
Phase
Start date October 21, 2018
Completion date November 30, 2020

See also
  Status Clinical Trial Phase
Completed NCT03832205 - Validation of Respiratory Rate and Heart Rate Measurements by Capaciflectors Placed in Four Locations on the Chest
Completed NCT04506684 - Reveal LINQ Respiration Clinical Study
Completed NCT03685227 - A Closer Look at Yoga Nidra: Sleep Lab Analyses N/A
Completed NCT04179279 - Comparative Analysis of a Non-contact Respiratory and Heart Rate Monitor Vs. a Conventional Clinically Validated Reference Monitor
Completed NCT03750344 - ChroniSense Polso Wrist Worn Respiration Rate Validation Study N/A
Completed NCT05366049 - The Effect of Methods Used in Oral Antipyretic Administration on the Vital Findings of the Child With Fever N/A
Completed NCT03148873 - RespiraSense Versus Capnography & Manual Counting
Recruiting NCT05263791 - Evaluation the Non-Inferiority of Airmod to Capnostream™35 N/A
Completed NCT05246358 - Respiratory Rate Validation Study - ChroniSense Polso N/A
Recruiting NCT05812378 - Respiratory Monitoring System Safety and Performance Study
Not yet recruiting NCT06292299 - The PARS Study: Paediatric Advanced Respiratory Service Study - An Observational Diagnostic Feasibility Study
Recruiting NCT05022264 - Remote Investigation and Assessment of Vital Signs
Completed NCT06086769 - High Flow Oxygen Therapy Effect on Healthy Subjects N/A
Completed NCT04104737 - Spire Medical Health Tag Respiratory Rate Validation in Adults N/A
Completed NCT04064645 - Bora Band Respiration Rate Study N/A
Completed NCT01472133 - Validation of Respiration Rate Algorithms N/A
Completed NCT03306537 - Sensor Validation Study - Quality Assurance
Active, not recruiting NCT03750318 - Validation Study on RENEW's Aingeal at KK Women's and Children's Hospital N/A
Completed NCT03754231 - Validation Study on RENEW's Aingeal at KK Women's and Children's Hospital N/A
Completed NCT04346498 - Can Kangarooing Small Babies on the Back of a Mother Keep Them Warm and Stable N/A