Respiratory Function Clinical Trial
Official title:
Acute Effects of a Heat-not-burn Tobacco Product on Pulmonary Function in Healthy Non Smokers.
IQOS ("I-Quit-Ordinary-Smoking,") is a type of "heat-not-burn" (HNB) tobacco product. There
is evidence of a growing number of young people who try IQOS as a 'safe' alternative of
cigarette. The effect of the acute exposure to IQOS smoke on pulmonary function of healthy
non smokers has not been studied extensively.
Objectives: Evaluation of the acute effects of IQOS on pulmonary function,exhaled CO, O2
Saturation, arterial pressure and heart rate.
Methods: Healthy non smokers, underwent exhaled CO measurement, spirometry including flows,
volumes and diffusion capacity, and measurement of their respiratory resistances at 5, 10 and
20 Hz (R5Hz, R10Hz and R20Hz) with the use of an impulse oscillometry system (IOS) before and
after the use of an IQOS. Additionally heart rate and arterial blood pressure were also
measured.
All participants underwent pulmonary function tests (PFT) (MasterScreen PFT, Jaeger, Wurzburg, Germany) and total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system).From the basic pulmonary measurements (flows and dynamic lung volumes), Forced Expiratory Volume in 1 second (FEV1), Forced Vital Capacity (FVC), Tiffenau index (FEV1/FVC, FEV1%), Peak Expiratory Flow (PEF), Maximal Expiratory Flow (MEF) at 25%, 50%, and 75% of vital capacity, Functional Residual Capacity (FRC), Total Lung Capacity (TLC), Residual Volume (RV), Diffusion Capacity (DLCO) were measured. Each manoeuvre was repeated for at least three technically acceptable forced expiratory flow curves in order to attain the best results. Respiratory impedance at 5 Hz (Z5Hz) and respiratory resistance at 5, 10, and 20 Hz (R5Hz, R10Hz, and R20Hz, respectively), reactance at 5, 10, and 20 Hz and resonant frequency were assessed with IOS. Heart rate, saturation of O2 (oxymetry) and arterial blood pressure were also measured. Exhaled CO measurement (piCO Smokerlyzer,Bedfont Scientific Ltd, Kent, U.K.) was performed After smoking heated tobacco (IQOS): 5 minutes after smoking IQOS , they repeated again PFTs, IOS, exhaled CO heart rate, saturation of O2 (oximetry) and arterial blood pressure measurements. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01143493 -
The Role of Glucocorticoid Receptor SNPs in Receptor Function and Metabolic Disease
|
||
Completed |
NCT04824573 -
Effects of Manual Therapy and Inspiratory Muscle Training
|
N/A | |
Recruiting |
NCT01881945 -
Validation of Study in Respiratory Physiology and it Interactions
|
N/A | |
Completed |
NCT03098784 -
Nanoparticles Emitted by Aircraft Engines, Impact on Respiratory Function
|
N/A | |
Not yet recruiting |
NCT04391361 -
The Safety and Effectiveness of Cholinergic Receptor Block Therapy in the Treatment of ALS
|
Phase 2 | |
Completed |
NCT06121960 -
Evaluation of Respiratory Function During Self-induced Cognitive Trance
|
N/A | |
Completed |
NCT03815799 -
The Effect of Ultrasound-Guided Erector Spinae Block on Respiratory Function After Laparoscopic Cholecystectomy
|
N/A | |
Active, not recruiting |
NCT01287000 -
Gulf Long-Term Follow-Up Study
|
||
Active, not recruiting |
NCT04519255 -
Study for Quantitative Analysis of the Recovered COVID-19 Patients by 18F-FDG-PET/CT
|
||
Not yet recruiting |
NCT05662072 -
Motor Imagery and Action Observation in Respiratory Training
|
N/A | |
Completed |
NCT03889990 -
Acute Effects of a Heat-not-burn Tobacco Product on Pulmonary Function
|
N/A | |
Completed |
NCT02074397 -
Distant Extrafascial Injection vs Subfascial Injection for Interscalene Block: Acute Pain Outcomes and Rates of Complications
|
N/A | |
Suspended |
NCT06198946 -
External Diaphragm Pacing Therapy and Correlation Analysis of Trunk Balance and Respiratory Function in Stroke Patients
|
N/A | |
Completed |
NCT03985917 -
Singing Groups for Seniors: Well-Being, Cognitive Function and Health
|
N/A | |
Not yet recruiting |
NCT02491762 -
The Effect of Breast Reconstruction Surgery Using Tissue Expanders on Respiratory Functions
|
N/A | |
Recruiting |
NCT06041126 -
The Effect of Clinical Parameters on Muscle Oxygenation in Patients With COPD
|
||
Completed |
NCT01748643 -
CURES: The Effect of Deep Curarisation and Reversal With Sugammadex on Surgical Conditions and Perioperative Morbidity
|
Phase 4 | |
Completed |
NCT06175286 -
Effect of a Respiratory Training Program on Woodwind and Brass Players
|
N/A |