Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03139617
Other study ID # USM/JEPeM/15100313
Secondary ID
Status Completed
Phase N/A
First received April 15, 2017
Last updated May 3, 2017
Start date June 2015
Est. completion date June 2016

Study information

Verified date May 2017
Source University of Science Malaysia
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study aimed to evaluate the efficacy of ultrasound guided femoral 3 in 1 block versus the blind technique single shot fascia iliaca compartment block as an analgesia method in patients prior positioning for spinal anaesthesia in femur fracture surgery. A total of 60 patients were enrolled and divided equally into 2 groups.


Description:

This study is to evaluate the efficacy of fascia iliaca compartment block comparing to femoral nerve block. If it is proven effective, this technique should be implemented as a method of analgesia (pain relief) prior positioning for spinal anaesthesia. As fascia iliaca compartment block is relatively easy to be done without the need of advanced equipment, it has the potential role for good pain management in patient with femur fracture. Thus this will reduce the need of intravenous or oral analgesic such as opioid or nonsteroidal anti-inflammatory drugs and side effects that comes with it.

This is a prospective single blind randomized study of a total of 60 patients ASA I - III who were scheduled to undergo fixation of femur fractures. Patients who fulfilled the criteria were recruited after informed consent was taken. This study was conducted in the operation theatres of the Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan.

Hypothesis

1. There is no difference in term of success rate between ultrasound guided Femoral 3 in 1 nerve block versus Single shot blind Fascia Iliaca Compartment Block prior positioning for spinal anaesthesia in femur fracture surgery.

2. There is no difference in term of analgesic effect between ultrasound guided Femoral 3 in 1 nerve block versus Single shot blind Fascia Iliaca Compartment Block prior positioning for spinal anaesthesia in femur fracture surgery.

3. There is no different in term of onset of analgesia between Femoral 3 in 1 nerve block versus Fascia Iliaca Compartment Block prior positioning for spinal anaesthesia in femur fracture surgery.

Recruitment and Randomization Eligible patients will be approach and offered to participate in this study prior operation. Agreed patients will have to sign informed consent Subject will be randomized into 2 groups using computer assisted randomization

Sample Size Calculation The sample size was calculated based on reduction of visual analog score in a study done by Newman et al with score 3.7±2.6, α = 0.05 and power of study 80%. The patients were randomized per a computerized generated random number and divided into two groups. Group A (FICB) n = 30, received single shot fascia iliaca compartment block (blind technique) and the other group B (FNB) n = 30 received ultrasound guided femoral 3 in 1 block. Initial target sample of 66 was calculated including drop out, however as there was no drop out from the study we decided to stop at 60 samples only. As 30 samples for each arm was adequate for a clinical study to be conducted and data acquired can be statistically analysed.

Study Protocol After ethic approval, written informed consent will be obtained from participants that met inclusion/exclusion criteria.

A total of 66 adults who are planned for open reduction internal fixation (ORIF) of proximal femur fracture will be enrolled. Easy sample random sampling using opaque and sealed envelope will be used to divide patient into Group 1 (Group Femoral 3 in 1 Block) and Group 2 (Fascia Iliaca Compartment Block) with ratio 1:1.

Random sampling will be done upon patient arrival to reception area in operation theatre complex. Both block will be performed by principal investigator in induction anaesthetic room while waiting for surgery. Data will be collected by registered nurse anaesthetist monitoring preoperatively and resident anaesthetist who's in charge in the operating theatre.

Block will be performed in induction room near the recovery area in operating theatre (OT) complex. Basic and standardized monitoring as listed by American Society of Anaesthesiologist (ASA) will be applied such as Non-invasive blood pressure monitoring (NIBP), Heart rate (HR), Oxygen saturation (SpO2) and electrocardiogram (ECG). Patient will be monitored continuously during the procedure. Apart from that, a variable performance oxygen delivery system will be given using nasal cannula at 3 litre/min. At least 1 functioning cannula will be made available with running IV drip. Preparation for emergency airway intervention and resuscitation drug will also be prepared before performing intended block.

In both group, block will be performed with patient in supine position, under aseptic technique using chlorhexidine solution and drape with sterile medical towel. Both group will be given Lignocaine 2% for local infiltration at puncture site. Ropivacaine 0.375% will be used in both groups with a total volume depends on weight basis.

Group 1 (Femoral 3 in 1 Block/FNB) This group will be given femoral 3 in 1 block Needle: Stimuplex or Locoplex 22-gauge 50-mm insulated needle Using Ultrasound guidance and peripheral nerve stimulator. Total Volume of Local anaesthetic: 20-40mls. Ultrasound will be use to locate the femoral vessel and nerve. Using 'in plane' technique, the needle will be puncture and advance in transverse plane at a 30 angle to the skin. Peripheral Nerve stimulator will be used if there is difficulty in recognizing the nerve, stimulation of the nerve will cause contraction of quadriceps femoris muscle. A total 20-40mls of local anaesthetic solution as per ideal body weight will be injected over a 2-3minutes duration after careful negative aspiration of blood to rule out inadvertent intravascular puncture. Careful aspiration will be done in every 3-5mls injection until a total of 20-40mls local anaesthetic being delivered.

Group 2: Fascia Iliaca Compartment Block (FICB) This group will be given fascia iliaca compartment block as shown in figure 3. Needle: Luer Lock cannula (Plexufix) 24-gauge 50-mm insulated needle Total Volume of Local anaesthetic: 20-40mls based on ideal body weight The technique is done as described by Dalens et al, 1989 using anatomical landmark technique. A line is drawn from pubic tubercle to anterior superior iliac spine (ASIS) and divided into 3 equal parts. The puncture point is 2-3cm distal to the point where medial 2/3rd and lateral 1/3rd of the line meet. The femoral vessel will be identified and should lie medial to the puncture site. The fascia iliaca block will be perform without using the nerve stimulator or ultrasound.

By using a blunted needle (24G, plexufix needle), identification of puncturing intended space is by feeling 2 times loss of resistance (described as clicks or plops). This indicates the puncture of fascia lata and fascia iliaca. After careful aspiration with syringe to rule out inadvertent vascular injection, a total volume of local anaesthetic (LA) will be given according to group allocation and body weight. Bolus of LA given in 2-3minutes duration with repeated aspiration. In case of accidental vascular puncture, needle is withdrawn and punctured site will be compressed for 5 minutes to avoid haematoma before reattempt lateral 1-2cm from initial site.

For both group, any signs of complication will be look for, documented and treated accordingly. Examples are:

1. Local anaesthetic toxicity such tingling sensation around mouth, metallic taste, light headache, confusion, altered conscious level, seizures, visual disturbances, arrhythmias and cardiovascular collapse

2. Swelling at site of puncture due to hematoma or localization of local anaesthetic

3. Bleeding from puncture site

Precaution to avoid complication from procedure:

1. Dose local anaesthetic should be precalculated to avoid toxicity, total maximum dose of Ropivacaine is 3mg/kg

2. Careful negative aspiration before giving intended local anaesthetic in titrating dose to avoid inadvertent vascular puncture

3. Total volume of local anaesthetic given in repeated aspiration and in titrating dose in 2-3 minutes' duration


Recruitment information / eligibility

Status Completed
Enrollment 60
Est. completion date June 2016
Est. primary completion date June 2016
Accepts healthy volunteers No
Gender All
Age group 18 Years to 65 Years
Eligibility Inclusion Criteria:

- ASA I - III with stable hemodynamic parameters

- Planned for open reduction internal fixation of fracture femur under spinal anaesthesia

Exclusion Criteria:

- Coagulopathy/ Bleeding diathesis

- Known allergy to amide local anaesthetic used in the study

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
Fascia Iliaca Compartment Block (FICB)
The FICB was done in the OT with standard monitoring with emergency airway intervention and resuscitation drug prepared before performing intended block. Patient was put in supine position, using aseptic technique, chlorhexidine solution and draped with sterile medical towel. Lignocaine 2% for local anaesthetic infiltration at punctured site.A blunted needle (Plexufix® 24G x 2", B Braun Melsungen AG 34209 Germany).A line was drawn from pubic tubercle to anterior superior iliac spine, the punctured point is 2-3cm distal to the point where medial 2/3rd and lateral 1/3rd of the line meet. Loss of resistance 2 times indicated the punctured of fascia lata and iliaca.A total volume of Ropivacaine 0.375% per body weight was given with repeated aspiration.
3 in 1 femoral block (FNB)
The FNB was done in the OT with standard monitoring with emergency airway intervention and resuscitation drug prepared before performing intended block.Patient was put in supine position, using aseptic technique, chlorhexidine solution and draped with sterile medical towel.Lignocaine 2% for local anaesthetic infiltration at punctured site.An insulated stimulating needle (Stimuplex® D Plus 22g x 2", B Braun Melsungen AG 34209 Melsungen Germany). Ultrasound was used to locate the femoral vessel and nerve and by using 'in plane' technique, the skin was punctured with the insulated needle and advance in transverse plane at around 30 angle to the skin. Local anaesthetic solution as per ideal body weight given after negative aspiration of blood .

Locations

Country Name City State
Malaysia University of Science Malaysia Hospital Kubang Kerian Kelantan

Sponsors (1)

Lead Sponsor Collaborator
University of Science Malaysia

Country where clinical trial is conducted

Malaysia, 

References & Publications (4)

Capdevila X, Biboulet P, Bouregba M, Barthelet Y, Rubenovitch J, d'Athis F. Comparison of the three-in-one and fascia iliaca compartment blocks in adults: clinical and radiographic analysis. Anesth Analg. 1998 May;86(5):1039-44. — View Citation

Dalens B, Vanneuville G, Tanguy A. Comparison of the fascia iliaca compartment block with the 3-in-1 block in children. Anesth Analg. 1989 Dec;69(6):705-13. Erratum in: Anesth Analg 1990 Apr;70(4):474. — View Citation

Lopez S, Gros T, Bernard N, Plasse C, Capdevila X. Fascia iliaca compartment block for femoral bone fractures in prehospital care. Reg Anesth Pain Med. 2003 May-Jun;28(3):203-7. — View Citation

Winnie AP, Ramamurthy S, Durrani Z. The inguinal paravascular technic of lumbar plexus anesthesia: the "3-in-1 block". Anesth Analg. 1973 Nov-Dec;52(6):989-96. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary The percentage of success rate between ultrasound guided femoral 3 in 1 block versus single shot blind fascia iliaca compartment block as analgesic method for positioning prior spinal anaesthesia in femur fracture surgery Using pin prick to test the sensory level at different dermatomes after given local anaesthetic following each block From the time of local anaesthetic injection to successful block at least 2 out of 3 dermatomes of either lateral femoral cutaneous nerve, femoral nerve or obturator nerve up to 30 minutes.
Secondary The onset of analgesia in term of minutes between ultrasound guided Femoral 3 in 1 nerve block versus single shot blind Fascia Iliaca Compartment Block prior positioning for spinal anaesthesia in femur fracture surgery. assessment of the patient pain severity post local anaesthetic injection after each block by using the visual analogue pain score chart From the time of local anaesthetic given to a reduction in visual analogue pain score to less than 2 up to 30 minutes.
Secondary The quality of blocks The quality of positioning the patients documented by the operator prior to giving spinal anaesthesia level From the sitting up the patients till successful spinal anesthesia was achieved up to 10 minutes.
See also
  Status Clinical Trial Phase
Completed NCT01903369 - Comparison of Intraneural and Extraneural Young's Modulus Using Shear Wave Elastography
Completed NCT03214536 - Erector Spine Block for Back Surgery N/A
Recruiting NCT02623387 - Ultrasound Guided Versus Standard Paravertebral Blockade in Breast Surgery N/A
Enrolling by invitation NCT03936790 - Dose-response Study of Spinally Administered Ropivacaine for Caesarean Section in Tall Parturients N/A
Completed NCT03965338 - Assessment of Brain Activity During Complex Fine Hand Movements: an fMRI Study N/A