Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05037370
Other study ID # FWH20200077H
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date April 22, 2021
Est. completion date October 31, 2023

Study information

Verified date December 2022
Source 59th Medical Wing
Contact JOSE E CAPO-APONTE, OD, PhD
Phone 210-292-2554
Email Jose.E.CapoAponte.ctr@health.mil
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a prospective randomized contralateral double-masked study. Each patient will be randomized as to which eye undergoes wave-front optimized (WFO) vs. wave-front guided (WFG) during Photorefractive keratectomy (PRK) or Laser-assisted in situ Keratomileusis (LASIK) surgery to determine which ablation profile provides the best visual outcome.


Description:

In 2015, the FDA approved a new laser ablation profile for performing laser corneal refractive surgery. Multiple sophisticated profiles have been developed in an attempt to optimize visual outcomes and reduce post-operative lower and higher-order optical aberrations. Among these include wave-front optimized (WFO) and wave-front guided (WFG) ablation profiles. The former compensated for corneal curvature to reduce spherical aberration and the latter, a more complicated ablation profile, was designed to minimize specific aberrations in an individual eye. Topographic profiles have also been used for over 17 years. These profiles consider the shape of the anterior corneal surface. The newest such topographic ablation profile, Contoura Vision, is a topography guided (TG) profile that, based on over 22,000 curvature data points captured using the VARIO Topolyzer, individualizes the ablation pattern. For comparison, WFO uses a patient's estimated average corneal curvature alone to create an ablation pattern. The addition of the VARIO Topolyzer adds a significant increase of pre-operative patient preparation. Anecdotally, between 1-3hrs of additional technician hours are required to prepare a patient for the Contoura Vision TG ablation profile. This will be a prospective randomized contralateral double-masked study. Patients will undergo the same standard of care preoperative evaluation and education as any other patient not enrolled in the study. The physician performing surgery will choose either LASIK or PRK, taking into account patient preference, preoperative data and overall clinical picture, ultimately choosing which is best for the patient. If a patient qualifies for both, the patient may choose either LASIK or PRK. Each patient will be randomized as to which eye undergoes a WFO treatment vs Contoura. At the time of surgery the patient will be blinded as to which eye receives which treatment, but the surgical team will not be blinded as to which procedure is performed. Post-operatively, the ophthalmic technicians and optometrists responsible for postoperative examinations (measurement of visual acuity, refractions, transcription of PRO's) will be blinded as to which eye underwent Contoura vs WFO. While treatments will vary, both have the same safety profile. Both involve sophisticated lasers to change the shape of the cornea to achieve the desired outcome. The variance comes in the type of pattern the laser uses to treat each individual. All post-operative care will be standard of care with medications being the same as if the patient were not enrolled in the study. Post-operative evaluations will take place at postoperative day 1, week 1, month 1, month 3, and month 6. All data collected will be standard pre- and post-operative ophthalmic refractive surgery measurements. This includes a standard medical history, especially to include prior eye surgeries or diseases. Pre-operative measurements include vision assessments, contrast sensitivity, pre- and post-dilation as well as keratometry and axial length measurements. The Contoura requires a separate set of data collection via the VARIO topolyzer. Intraoperative data collected will include variables such as actual treatment outcomes and laser settings. Post-operative measurements will consist of many of the same measurements as those obtained preoperatively including uncorrected and corrected visual acuity, and refractive measurements. A symptoms-based questionnaire specific to corrective eye surgery (PROWL) will be given to patients before and after surgery during routine follow-ups. Each PROWL is specific to an individual eye, not specific to the surgery performed in each eye (i.e. the same PROWL questionnaire will be used regardless of whether the patient underwent PRK or LASIK). All PROWL data will be compared pre- and post-operatively and will be stratified based on surgery.


Recruitment information / eligibility

Status Recruiting
Enrollment 400
Est. completion date October 31, 2023
Est. primary completion date April 30, 2023
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 21 Years to 50 Years
Eligibility Inclusion Criteria: - Meet requirements for PRK or LASIK i.e., Stable <= .5 D change MRSE) - DOD beneficiaries age 21-50 years - Local pts (w/i 60 mi) who will be in the area for at least 6 months post surgery - Willing to complete all required follow-up visits Exclusion Criteria: - No meeting requirements for PRK or LASIK - Desiring monovision treatment - Anisometropia >2D spherical equivalent - Prior ocular surgeries / trauma / problem - History of dry eyes - Hyperopia - Mixed astigmatism - Inability to capture VARIO topolyzer scans - Pregnant (or who plans to be within 6 months after surgery) - Breastfeeding any time during the study - History of herpetic disease

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Wave-Front Optimized (WFO) ablation vs Topography-guided (TG) ablation
Patient will undergo PRK or LASIK using WFO ablation in one eye and TG ablation on contralateral eye

Locations

Country Name City State
United States Joint Warfighter Refractive Surgery Center at WHASC San Antonio Texas

Sponsors (1)

Lead Sponsor Collaborator
59th Medical Wing

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Post-operative refractive error The Post-Operative sphere equivalent refractive error for eyes undergoing Wave-Front Optimized (WFO) ablation vs Topography-guided ablation 6 months post-surgery
Secondary Post-operative Uncorrected Visual Acuity The Post-Operative visual acuity for eyes undergoing Wave-Front Optimized (WFO) ablation vs Topography-guided ablation 6 months post-surgery
See also
  Status Clinical Trial Phase
Completed NCT00565695 - Evaluation of the Aspheric ReSTOR Intraocular Lens (IOL) After Routine Cataract Extraction N/A
Completed NCT05406973 - Comparison Between the SBK Microkeratome Versus Femtosecond Laser in Flap Creation During LASIK Surgery for Myopia N/A
Active, not recruiting NCT05658718 - Factors Influencing Nocturnal Symptoms After Refractive Surgery.
Withdrawn NCT00466908 - Accuracy of the Pentacam and IOL Master to Calculate the Effective Corneal Power After Corneal Refractive Surgery
Completed NCT05060094 - Comparison of Outcomes Between TransPRK and Off-flap Epi-LASIK
Completed NCT04396990 - The RESTORE Study, A Randomized, Controlled, Masked (Reading Center) Prospective Study
Completed NCT03938883 - Ocular Bandage Gel (OBG) Pivotal Trial in Patients Undergoing Photorefractive Keratectomy ("PRK") N/A
Recruiting NCT04281862 - DEXTENZA Compared to Topical Prednisolone in Patients Undergoing Bilateral LASIK Surgery Phase 4
Completed NCT03791684 - Accelerated Versus Standard CXL in the Treatment of Ectasia Post Refractive Surgery and Penetrating Keratoplasty. N/A
Completed NCT04684888 - Femto-flap Versus SBK Flap,Predictability and Variability N/A
Recruiting NCT06264804 - Risk Factors for Progressive Suction Loss in Corneal Refractive Surgery
Completed NCT03569423 - Comparison Between TPRK Versus AAPRK in Correction of Myopia N/A
Recruiting NCT02614625 - Spectral-domain Optical Coherence Tomography of the Eye N/A
Completed NCT04899258 - Evaluation of the Effect of Myopic Femtosecond Laser Assisted-LASIK on Anterior Chamber Flare Values and Corneal Endothelial Cells: A Prospective Before-and-After Study N/A
Completed NCT00742950 - Refractive Change Induced by 2.8-mm Corneal Incision N/A
Completed NCT03597906 - Topography Guided LASIK by Different Protocols for Treatment of Astigmatism N/A