Rectus Diastasis Clinical Trial
Official title:
Effect of Ultrasound Cavitation on Static and Dynamic Balance in Obese Postnatal Women With Diastasis Recti
Verified date | March 2024 |
Source | Cairo University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
the aim of this study is to investigate the efficacy of ultrasound cavitation on static and dynamic balance in obese postnatal women with diastasis recti
Status | Completed |
Enrollment | 60 |
Est. completion date | August 9, 2023 |
Est. primary completion date | August 9, 2023 |
Accepts healthy volunteers | No |
Gender | Female |
Age group | 25 Years to 35 Years |
Eligibility | Inclusion Criteria: 1. All women had a diastasis recti more than 2.5 cm and less than 4 cm in supra umbilical region. 2. Their ages were ranged from 25: 35 years. 3. Their BMI was more than 30 Kg/ m2. 4. All women were with lumbar hyperlordosis. 5. All women were multipara. 6. Their mode of delivery was normal vaginal delivery. 7. They were selected from 2: 5 months postnatal. Exclusion Criteria: 1. Previous cesarean section. 2. Previous abdominal and/ or back operation. 3. Spinal disorders. 4. Abdominal skin diseases. 5. Serious diseases such as heart disease, pace maker, uncontrolled diabetes or hypertension, autoimmune disease, malignancy, gastric ulcer, liver or renal failure and any other contraindication for body sculpting-weight loss. |
Country | Name | City | State |
---|---|---|---|
Egypt | Asmaa Maher Ahmed Zahran | Giza |
Lead Sponsor | Collaborator |
---|---|
Cairo University |
Egypt,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Static postural balance | The Biodex Balance System SD (model: TP-3040-15, DC input: 19V-6.32A, connected to computer software version 4.0.06, 2017, serial number: R712010010, made in Taiwan) will be used to measure overall stability index of static postural balance for all patients | up to eight weeks | |
Primary | Dynamic postural balance | The Biodex Balance System SD (model: TP-3040-15, DC input: 19V-6.32A, connected to computer software version 4.0.06, 2017, serial number: R712010010, made in Taiwan) will be used to measure overall stability index of dynamic postural balance for all patients | up to eight weeks | |
Secondary | Abdominal subcutaneous fat thickness | Ultrasound imaging unit (Mindary DP10, linear probe, with 10 MHz frequency, serial number: bn- 75013216, made in China) will be used to measure abdominal subcutaneous fat thickness at the umbilical level from supine lying position for all patients | up to eight weeks | |
Secondary | Inter recti distance | Ultrasound imaging unit (Mindary DP10, convex probe, with 5 MHz frequency, serial number: bn- 75013216, made in China) will be used to measure resting inter recti distance 2.5 cm above the upper margin of umbilicus from crock lying position for all patients | up to eight weeks | |
Secondary | Lumbar lordotic angle | Spinal mouse (MEDIMOUSE) IDIAG M360 pro, pc-Software, 7.4.0., serial number: *112D2A24*, made in Switzerland) will be used to measure lumbar lordotic angle from standing position | up to eight weeks |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05446675 -
Endoscopic eTEP Versus Open Rives-Stoppa
|
||
Withdrawn |
NCT05229692 -
Effect of Neuromuscular Electrical Stimulation on the Post-Operative Abdominoplasty Patient.
|
N/A | |
Recruiting |
NCT04182412 -
Abdominal Rectus Diastasis (ARD) Reconstruction
|
N/A | |
Completed |
NCT05287282 -
Impact of TECAR in Treatment of Rectus Diastasis
|
N/A |