Clinical Trials Logo

Clinical Trial Summary

Radiation now becomes a dreadful effect as its outcomes are tremendous to be expected. As a result, anesthetists become an inevitable target to the radiation exposure since they have to monitor patients closely during the operation. Unfortunately, radiation may not have an immediate sequelae, but an accumulation of adverse effects.

These sequelae happen by means of direct exposure and reflection. The reflected rays is inversely proportional to the distance between the origin and the target. Practically, the radiation source can be protected by individual cover and glass shield.

Siriraj hospital is a tertiary, general university hospital with 2,200 beds. Annually, an Endoscopy centre has over 700 patients undergoing endoscopic retrograde cholangio pancreaticography (ERCP). Normally, fluoroscopy for pancreatic and biliary ducts visualisation is needed under anesthesia. Though the procedure is operated in a well-equipped, radiating-protection room; many medical personnel including 1-2 endoscopists, 2 scrub nurses, 1-2 anesthetists and 1 x-ray man, still have a chance of irradiation.

During ERCP, all medical personnel particularly anesthetists are rinsed by radiation from here and there. Though they always wear lead aprons and collar shields to protect themselves from the rays, they are normally in the position - less than 1 meter - close to the fluoroscopy.

Due to the advancement in technology, anesthetists can remotely monitor patients during the surgical procedure. This might cause a lesser effect of ray upon them. As a result, whether or not the positioning of anesthesia personnel relating to the distance of x-ray source would help to alleviate the effect of radiation exposure.


Clinical Trial Description

This study has been approved by Siriraj IRB. Inclusion criteria were the patient who underwent ERCP procedure. Exclusion criteria were none. The project was terminated when 19 August 2016 A total of 222 cases was included without the need of informed consent.

At the Endoscopic unit A nurse anesthetist performed venous cannulation on the right forearm and transfused with 5% dextrose in half-strength normal saline. Then the patient was transferred to the ERCP theatre.

The patient was monitored with non-invasive blood pressure (NIBP), percutaneous arterial oxygen saturation (SpO2), and electrocardiogram (EKG) and administered with oxygen 3LPM via nasal cannula.

A co-researcher reset and prepared 4 pocket dosimeters (PDS) and labelled as PDSa1, PDSa2, PDSb1 and PDSb2.

The PDSa1 and PDSa2 were placed on the outside and inside of a lead shirt respectively. The shirt-covered box was close to an anesthetic machine. This box would represent anesthetic personnel on duty and marked as position A.

The PDSb1 and PDSb2 were placed on the outside and inside of the glass shield of control room respectively. This glass shield would represent all personnel working in the operating theatre and marked as position B.

Both position A and B were 160 cm. above the floor. After an anesthesiologist administered a narcotic and an induction agent to a patient (total intravenous anaesthesia, TIVA), an endoscopist commenced the procedure. A co-researcher turned on all PDS devices as soon as the surgeon started a fluoroscopy, and turned it off whenever the use of radiative source was over. When the study was completed, the PDA devices was kept in a solid and dry place. The lead apron was hanged in the specific area and covered by a bag.

The devices

A lead apron was 0.5 mm. and 0.25 mm. in thickness on the front and back (BT medical) respectively. A thyroid shield was 0.5 mm. in thickness. A paper box was 30x1510 cm. in dimension. A radiative dosimeter (Ludlum model 25-IS &25-IS-1 Personal Radiation Monitor, 501 Oak street, Sweetwater, Texas, USA) had characteristic details as follow:

Ludlum model 25-IS & Model 25-IS-1 Radiation detected Gamma (X ray) typically < 18 count per minute per milliroentgen/hr.

Beta response typically < 0.10 milliroentgen/hr Display range For 25-IS: 0.01 milliroentgen/hr to 10 sievert/hr For 25-IS-1: 0.01 millisievert/hr to 10 sievert/hr Size. 7.6 x5.4x1.7 cm (H x W x thickness) Weight. 158.6 g. Including batteries Linearity. Reading within 10% of true value within calibration range

Analysis of data Data were expressed as mean and standard deviation and analysed by using SPSS version 18.0. Categorical data were compared by using Chi-square test; while, the recorded data using dependent t-test. A p < 0.05 was considered statistically significant difference at 95% confidence interval. ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Prevention


Related Conditions & MeSH terms


NCT number NCT02985164
Study type Interventional
Source Siriraj Hospital
Contact
Status Completed
Phase Phase 3
Start date September 2015
Completion date December 2016

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05006976 - A Naturalistic Trial of Nudging Clinicians in the Norwegian Sickness Absence Clinic. The NSAC Nudge Study N/A
Not yet recruiting NCT03678519 - Occupational Health Hazards Among Flour Mills Workers
Completed NCT05507944 - FeNO Hairdressers Pilot
Enrolling by invitation NCT05766397 - Prehospital Inhaled Methoxyflurane Non-Clinical Occupational Exposure Study Phase 4
Completed NCT05511896 - Effects of a 60-min Repeated Trunk Flexion Protocol on Trunk Neuromuscular Properties. N/A
Completed NCT03002987 - Active Pregnancy Policy at Work. Greater Wellbeing and Lower Sickness Absence N/A
Active, not recruiting NCT03048630 - Reducing Chemical Exposures in Nail Salons N/A
Completed NCT04591756 - Effectiveness of Respiratory Protection During Simulated Resuscitation: a Prospective Cohort Study N/A
Completed NCT04075279 - Heart at Work Study
Enrolling by invitation NCT05651477 - Relationship Between Health Risk and Occupational Exposure of ED
Completed NCT05097612 - Evaluation of a Soft Exoskeleton to Support Forward Leaning and Lifting N/A
Completed NCT02661074 - Anisakis Blastocystis Cryptosporidium Fish Prevalence N/A
Active, not recruiting NCT05811767 - The Esbjerg Cohort - A Cross-sectional Study About Work Ability and Musculoskeletal Pain in 55 to 70 Years Old Workers
Completed NCT00342394 - Fungicide Exposure Assessment Among Apple and Peach Farmers in the Argicultural Health Study
Not yet recruiting NCT03695302 - Knowledge , Attitude and Practice (KAP) of Fifth Year Undergraduate Dental Students on Post Exposure Prophylaxis
Recruiting NCT05849168 - High-Intensity Interval Training to Improve Symptoms of Deployment-Related Respiratory Disease N/A
Completed NCT04879082 - Identification Of Occupational Exposures In Patients With ILD
Recruiting NCT06193018 - Ergonomic Effects of Using a Professional Passive Exoskeleton
Not yet recruiting NCT06188312 - Occupational Hazards Among Workers of Superphosphate Fertilizer Factory
Completed NCT03855163 - Effects of Regulatory Tools on Work Environment and Employee Health N/A