Clinical Trials Logo

Clinical Trial Summary

Radial artery cannulation can be performed under short-axis ultrasound guidance. However, the first puncture success rate was low in patients with hypotensive patients. Compared with the conventional approach, the modified approach combined the ultrasonic location system with a dynamic needle tip positioning technique. The aim of our study is to compare the first puncture success rate and safety between the two approaches of ultrasound-guided radial artery cannulation in hypotensive ICU patients.


Clinical Trial Description

Hypotensive patients in the intensive care unit may have extremely unstable hemodynamics. Blood pressure is the most important outcome in the diagnosis and treatment of shock. Vasopressor drugs are often required to maintain blood pressure in addition to fluid infusion. Noninvasive blood pressure measurement is unable to meet the clinical requirements. It is necessary to establish an invasive blood pressure monitoring method as soon as possible that can observe the real-time pressure. Radial artery cannulation has become the most commonly used due to its superficial location and less severe complication. However, radial artery cannulation is difficult to achieve in hypotensive patients due to weak radial artery pulsation, small arterial diameter, and peripheral vasospasm as blood flow is directed toward central vessels. Some studies have shown that ultrasound-guided cannulation is more successful than the palpation technique. However, the success rate is largely dependent on the ultrasound operator's experience and skills. The operator requires good hand-eye coordination, technical skills, and some experience to overcome this shortcoming of ultrasound, which limits the advantages of ultrasound-guided vascular puncture, especially for operators with insufficient experience. There are 2 basic approaches in needling techniques: short-axis out-of-plane(SA-OOP) and long-axis in-plane(LA-IP) techniques. In-plane technology requires the operator to be very skilled at ultrasound technology, which is more dependent on experience and can be difficult for novices to master; on the other hand, given that the long axis is subject to slice-thickness artifacts, due to the measurable thickness of the ultrasound beam itself, the cannula in the long axis appears to be in the same plane as the extremely small radial artery, even when the cannula has not been successfully inserted into the artery. Therefore, we prefer the out-of-plane technique. The short-axis view has the advantages of providing better visualization of the surrounding structures and easier imaging which is convenient for novices to master. The procedure of radial artery puncture can be divided into 3 steps. The first step is to locate the puncture site, the second step is the puncture, and the last step entails the insertion of the cannula into the radial artery. The first step is particularly important because appropriate localization facilitates the success of the puncture and insertion. The first difficulty encountered during radial artery puncture is the exact positioning of the puncture point. Ultrasound with developing lines guided by dynamic ultrasound has achieved a good effect in patients without hypotension. In the group with the modified technique, we use the developing line to locate the puncture site. The second difficulty encountered during radial artery puncture is the risk of posterior wall penetration. With the dynamic needle tip positioning(DNTP) technique, the operator keeps real-time track of the position of the needle tip at all times which significantly reduces the chance of posterior wall perforation. We combined the developing line and DNTP technique in the modified group and assume that the technique theoretically increases the success rate and decreases the complication rate of radial artery puncture. Therefore, in this trial, we compared the success rate of radial artery puncture using the traditional method and modified technique in hypotensive ICU patients. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04806932
Study type Interventional
Source Shanghai Zhongshan Hospital
Contact Hongyu He, PhD
Phone 021-64041990
Email he.hongyu@zs-hospital.sh.cn
Status Recruiting
Phase N/A
Start date April 11, 2021
Completion date February 28, 2024

See also
  Status Clinical Trial Phase
Completed NCT03920423 - Impact Factors to Success Without Posterior Wall Puncture Using Dynamic Approach N/A