Clinical Trials Logo

Clinical Trial Summary

This study will record vital signs (heart rate and blood oxygen levels) using a new cell phone integrated biosensor and compare it to routine measurements carried out in the clinics and hospital at UCSD. Cell phones will be given to a selected group of subjects for use at home and data collected.


Clinical Trial Description

Maxim Vital Sign study is a 2 part, investigator initiated observational study with Maxim Integrated aimed to compare vital sign readings using 2 prototype versions of new cell phone based mobile biosensors with standard of care (SOC). Adult subjects will be recruited from UCSD outpatient clinics, AVRC clinic, emergency department (ED), and hospitals. Vital signs will be measured using cell phone based mobile biosensors and SOC. For Phase 1, up to 800 subjects will be recruited (700 adults and up to 100 adolescents). 250 subjects (200 adults and up to 50 adolescents) will participate in phase 1a and 550 subjects (500 adults and up to 50 adolescents) will participate in phase 1b. An additional group of 30 adult subjects will be recruited from outpatient clinics for participation in phase 2. Phase 1a: Two identical copies of the device will be tested during the first part of phase 1 with a total of 125 subjects (100 adults and up to 25 adolescents). Each prototype version will be tested on up to 125 subjects (100 adults and 25 adolescents) and compared to readings obtained by Welch-Allyn Spot Vital Signs monitor. Data will be obtained on the usability and accuracy of the measurements with each initial prototype. Measurement particularly of SpO2 depends on accurate finger position. Current SpO2 monitors encase the finger and immobilize it in order to obtain an accurate measurement. Maxim Integrated, in collaboration with DD Studios, Carlsbad CA, and Specialists in Global Health, Encinitas CA, have developed prototypes, which will be tested to inform design flaws in future prototypes. Phase 1b: Based on the results from phase 1a, one of the prototypes will be selected for further testing (the one with the least within-instrument variation). During Phase 1b, vital sign readings will be collected with the selected Maxim biosensor prototype and one of the Welch-Allyn Spot Vital Signs monitor simultaneously. The subjects will be recruited from both outpatient and hospital settings for accuracy and usability. A total of 550 subjects (500 adults and 50 adolescents) will be recruited for this part of phase 1. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04233827
Study type Observational
Source University of California, San Diego
Contact Sara H Browne, MD MPH
Phone 619 543 8080
Email shbrowne@health.ucsd.edu
Status Recruiting
Phase
Start date October 20, 2016
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Active, not recruiting NCT02846974 - Calibration and Validation of High Quality Low-Cost 3D Printed Pulse Oximeter
Completed NCT03383757 - U-TruSignal SpO2 Testing in Neonates N/A
Completed NCT02987985 - Efficacy of Opioid-free Anesthesia in Reducing Postoperative Respiratory Depression in Children Undergoing Tonsillectomy Phase 3
Completed NCT05185427 - Pulse Oximetry and Skin Pigmentation - Peds
Terminated NCT03843489 - SpO2 Accuracy In Vivo Testing for Neonates & Infants N/A
Recruiting NCT06298422 - Oxygen Saturations Across Tones of Skin
Completed NCT01472133 - Validation of Respiration Rate Algorithms N/A
Completed NCT01613222 - SpO2 System Accuracy Testing With Different Sensors N/A
Enrolling by invitation NCT05681637 - SpO2 Difference Between Fingers of the Hand During Sequential Desaturation and Step Resaturation N/A
Completed NCT05657665 - Skin Tone Measurement Method Investigation for Pulse Oximetry
Enrolling by invitation NCT05657288 - SpO2 Comparison Between Commercial Smartwatch and Medical-grade Pulse Oximeter During Hypoxia N/A
Not yet recruiting NCT05994417 - Beyond Race: Objectively Assessed Skin Color and Its Association With Pulse Oximeter Bias in Critically Ill Infants
Recruiting NCT05554510 - Pulse Oximetry Errors in Hospitalized Patients Across Varying Skin Pigmentation
Recruiting NCT06063148 - Neonatal Pulse Oximetry Disparities Due to Skin Pigmentation N/A