Pulse Oximetry Clinical Trial
Official title:
Mobile Biosensor for Measuring Vital Signs in Healthcare and Home Settings
This study will record vital signs (heart rate and blood oxygen levels) using a new cell phone integrated biosensor and compare it to routine measurements carried out in the clinics and hospital at UCSD. Cell phones will be given to a selected group of subjects for use at home and data collected.
Maxim Vital Sign study is a 2 part, investigator initiated observational study with Maxim Integrated aimed to compare vital sign readings using 2 prototype versions of new cell phone based mobile biosensors with standard of care (SOC). Adult subjects will be recruited from UCSD outpatient clinics, AVRC clinic, emergency department (ED), and hospitals. Vital signs will be measured using cell phone based mobile biosensors and SOC. For Phase 1, up to 800 subjects will be recruited (700 adults and up to 100 adolescents). 250 subjects (200 adults and up to 50 adolescents) will participate in phase 1a and 550 subjects (500 adults and up to 50 adolescents) will participate in phase 1b. An additional group of 30 adult subjects will be recruited from outpatient clinics for participation in phase 2. Phase 1a: Two identical copies of the device will be tested during the first part of phase 1 with a total of 125 subjects (100 adults and up to 25 adolescents). Each prototype version will be tested on up to 125 subjects (100 adults and 25 adolescents) and compared to readings obtained by Welch-Allyn Spot Vital Signs monitor. Data will be obtained on the usability and accuracy of the measurements with each initial prototype. Measurement particularly of SpO2 depends on accurate finger position. Current SpO2 monitors encase the finger and immobilize it in order to obtain an accurate measurement. Maxim Integrated, in collaboration with DD Studios, Carlsbad CA, and Specialists in Global Health, Encinitas CA, have developed prototypes, which will be tested to inform design flaws in future prototypes. Phase 1b: Based on the results from phase 1a, one of the prototypes will be selected for further testing (the one with the least within-instrument variation). During Phase 1b, vital sign readings will be collected with the selected Maxim biosensor prototype and one of the Welch-Allyn Spot Vital Signs monitor simultaneously. The subjects will be recruited from both outpatient and hospital settings for accuracy and usability. A total of 550 subjects (500 adults and 50 adolescents) will be recruited for this part of phase 1. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT02846974 -
Calibration and Validation of High Quality Low-Cost 3D Printed Pulse Oximeter
|
||
Completed |
NCT03383757 -
U-TruSignal SpO2 Testing in Neonates
|
N/A | |
Completed |
NCT02987985 -
Efficacy of Opioid-free Anesthesia in Reducing Postoperative Respiratory Depression in Children Undergoing Tonsillectomy
|
Phase 3 | |
Completed |
NCT05185427 -
Pulse Oximetry and Skin Pigmentation - Peds
|
||
Terminated |
NCT03843489 -
SpO2 Accuracy In Vivo Testing for Neonates & Infants
|
N/A | |
Completed |
NCT01472133 -
Validation of Respiration Rate Algorithms
|
N/A | |
Completed |
NCT01613222 -
SpO2 System Accuracy Testing With Different Sensors
|
N/A | |
Enrolling by invitation |
NCT05681637 -
SpO2 Difference Between Fingers of the Hand During Sequential Desaturation and Step Resaturation
|
N/A | |
Completed |
NCT05657665 -
Skin Tone Measurement Method Investigation for Pulse Oximetry
|
||
Completed |
NCT06454318 -
Screening Moderate to Severe Obstructive Sleep Apnea With Wearable Device
|
||
Enrolling by invitation |
NCT05657288 -
SpO2 Comparison Between Commercial Smartwatch and Medical-grade Pulse Oximeter During Hypoxia
|
N/A | |
Not yet recruiting |
NCT05994417 -
Beyond Race: Objectively Assessed Skin Color and Its Association With Pulse Oximeter Bias in Critically Ill Infants
|
||
Recruiting |
NCT05554510 -
Pulse Oximetry Errors in Hospitalized Patients Across Varying Skin Pigmentation
|
||
Enrolling by invitation |
NCT06298422 -
Oxygen Saturations Across Tones of Skin
|
||
Recruiting |
NCT06063148 -
Neonatal Pulse Oximetry Disparities Due to Skin Pigmentation
|
N/A |