Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT05127915
Other study ID # PROT-CI2021
Secondary ID
Status Active, not recruiting
Phase N/A
First received
Last updated
Start date January 27, 2023
Est. completion date December 31, 2026

Study information

Verified date August 2023
Source Adient Medical
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The objective of the study is to evaluate the safety and efficacy of the Adient absorbable filter for the prevention of pulmonary embolism (PE: blood clot in the lungs). PE claims the lives of over 100,000 Americans each year, more than breast cancer, traffic fatalities and HIV combined. Pharmaceutical anticoagulation (blood thinners) that reduce blood clot formation represent the standard of care for treating patients at risk for PE. However, for people who are temporarily unable to use anticoagulants, such as those who have suffered major trauma or those who are scheduled for surgical procedures, inferior vena cava (IVC) filters are used to help protect against PE. These blood filters prevent large blood clots that originate in the deep veins of the legs (deep vein thrombosis (DVT)) from reaching your lungs causing a potentially life-threatening PE. Conventional metal IVC filters have been proven effective at reducing the incidence of PE, however, most require retrieval. If not retrieved within a timely manner (months), they can perforate the IVC, impale nearby organs with their barbed struts, and cause blood clots. In contrast, the Adient absorbable filter traps blood clots similar to conventional metal IVC filters, but following the 8 week protection period, the filter itself breaks down into carbon dioxide and water. Hence no filter retrieval is required and complications are less likely due to the shortened indwell time. Once blood clots are trapped in the absorbable filter, the body's thrombolytic enzymes dissolve the clots within weeks while the filter itself resorbs in 6 to 8 months. The absorbable filter is braided from absorbable suture that has been proven safe over 4 decades. The question being addressed with the randomized controlled trial portion is whether the placement of the absorbable filter in addition to current best practice PE prevention (sequential compression machines, compression stockings, and anticoagulants when indicated) significantly reduces the incidence of clinically significant PE in high risk subjects. The absorbable filter will be indicated for the temporary prevention of PE in patients with transient high risk for venous thromboembolism (DVT and/or PE) with or without venous thromboembolic disease and as an enhancement to pharmaceutical anticoagulation and mechanical prophylaxis.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 854
Est. completion date December 31, 2026
Est. primary completion date May 31, 2026
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility INCLUSION CRITERIA: Aged 18 years or older Willing to comply with the specified follow-up requirements including contrast enhanced CTs for the 9-month duration of the study For female subjects of childbearing potential: a negative pregnancy test within 48 hours prior to the implantation procedure For the prophylactic cohort, high risk VTE denoted by either: Caprini score > 8 for surgical ICU, Parvizi score = 150 for TKA (total knee replacement), ISS score = 24 for trauma. For the therapeutic cohort, documented VTE per the following: Pulmonary thromboembolism when anticoagulants are contraindicated, Failure of anticoagulant therapy in thromboembolic diseases, Emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced. Requirement of temporary PE protection (8 weeks) based on clinical judgment Fully informed subject or caretaker consent having executed an Institutional Review Board (IRB) or approved informed consent. EXCLUSION CRITERIA: Expected high VTE risk to extend beyond 8 weeks. Vena cava filter currently implanted History of abdominal or pelvic radiation therapy Previous IVC filter placement/retrieval within 6 months prior to randomization Confirmed positive blood cultures within the last 48 hours if there is bacteremia Known sensitivity to radiographic contrast medium that cannot be adequately prophylactically pre-medicated Known allergy or intolerance to IVC filter materials (i.e. PDSII absorbable suture) Pregnant, lactating, or plans to become pregnant during investigation follow-up period Renal insufficiency (GFR < 60) or requiring renal replacement therapy IVC effective diameter (D) <16 mm or >28 mm anywhere within L1-L4, D = v(AP*Lat) Less than 7cm from inferior-most renal vein to the iliac vein confluence Duplication of the IVC Any thrombus or occlusion in IVC on pre-procedural CT cavogram Life expectancy of < 12 months Simultaneous participation in another investigative drug or device trial that has not reached its primary endpoint Other co-morbid condition that, in the opinion of the Investigator, could limit the subject's ability to participate in or would affect the scientific integrity of the study Previously enrolled in a clinical investigation of the Adient filter. For Roll In, patient has advanced heart failure or recent (6 weeks) myocardial infarction. - - - Advanced heart failure is defined by NYHA class IV or AHA/ACC/HFSA stage D or LVEF < 40%. Subjects with MI diagnosed with ECG alone without MI history and symptoms are not excluded.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Adient absorbable filter + best practice VTE prophylaxis
Adient absorbable filter helps prevent PE during an 8 week protection period then gradually breaks down into carbon dioxide and water within 6 to 8 months. The absorbable filter does not require removal.
best practice VTE prophylaxis
Best practice VTE prophylaxis includes sequential compression machines, compression stockings, and anticoagulants (blood thinners) when indicated.

Locations

Country Name City State
United States University of Colorado Anschutz Medical Campus Aurora Colorado
United States IU Health University Hospital Indianapolis Indiana

Sponsors (3)

Lead Sponsor Collaborator
Adient Medical Avania, ICON plc

Country where clinical trial is conducted

United States, 

References & Publications (6)

Dria SJ, Eggers MD. In vitro evaluation of clot capture efficiency of an absorbable vena cava filter. J Vasc Surg Venous Lymphat Disord. 2016 Oct;4(4):472-8. doi: 10.1016/j.jvsv.2016.05.006. Epub 2016 Jul 25. — View Citation

Eggers M, Rousselle S, Urtz M, Albright R, Will A, Jourden B, Godshalk C, Dria S, Huang S, Steele J. Randomized Controlled Study of an Absorbable Vena Cava Filter in a Porcine Model. J Vasc Interv Radiol. 2019 Sep;30(9):1487-1494.e4. doi: 10.1016/j.jvir.2019.03.010. Epub 2019 Jun 13. — View Citation

Eggers MD, McArthur MJ, Figueira TA, Abdelsalam ME, Dixon KP, Pageon LR, Wallace MJ, Huang SY. Pilot in vivo study of an absorbable polydioxanone vena cava filter. J Vasc Surg Venous Lymphat Disord. 2015 Oct;3(4):409-420. doi: 10.1016/j.jvsv.2015.03.004. Epub 2015 Jun 18. — View Citation

Eggers MD, Reitman CA. In vitro analysis of polymer candidates for the development of absorbable vascular filters. J Vasc Interv Radiol. 2012 Aug;23(8):1023-30. doi: 10.1016/j.jvir.2012.05.039. — View Citation

Elizondo G, Eggers M, Falcon M, Trevino M, Marrufo R, Perez C, Nunez E, Moreno R, Mitchell A, Sheppard A, Dria S, Jay T, Kirk R, Hovsepian D, Steele J. First-in-Human Study with Eight Patients Using an Absorbable Vena Cava Filter for the Prevention of Pulmonary Embolism. J Vasc Interv Radiol. 2020 Nov;31(11):1817-1824. doi: 10.1016/j.jvir.2020.07.021. Epub 2020 Sep 29. — View Citation

Huang SY, Eggers M, McArthur MJ, Dixon KA, McWatters A, Dria S, Hill LR, Melancon MP, Steele JR, Wallace MJ. Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine. Radiology. 2017 Dec;285(3):820-829. doi: 10.1148/radiol.2017161880. Epub 2017 Jul 14. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Primary Effectiveness Endpoint - Prophylactic Cohort: incidence of new clinically significant PE Clinically significant PE includes asymptomatic proximal PE screened at 2 weeks, in addition to symptomatic PE through 8 weeks post index event confirmed by computed tomography (CT) angiography. Proximal PE includes thrombus (blood clots) observed in the pulmonary trunk, main pulmonary arteries, or lobar arteries. 2 weeks for asymptomatic proximal PE screening and through 8 weeks for symptomatic PE
Primary Primary Composite Safety Endpoint - Prophylactic Cohort: incidence of absorbable filter deployment without complications Potential complications include: (a) caval thrombotic occlusion within 9 months, (b) all-filter embolization within 9 months, (c) serious filter-related complications within 9 months, (d) filter placement procedural related Series Adverse Events (SAE) within the perioperative period (96 hours), (e) filter placement vascular access site SAE within the perioperative period, (f) symptomatic PE subsequent to filter deployment within 9 months. 96 hours to 9 months depending on the safety parameter
Primary Primary DVT Safety Endpoint - Prophylactic Cohort: incidence of all DVT post index event All DVT includes both symptomatic DVT and asymptomatic DVT screened at 2 weeks, 10 weeks and 9 months. 9 months overall duration
Primary Primary Composite Safety and Effectiveness Endpoint - Therapeutic Cohort: composite rate of technical filter placement success without complications Potential complications include (a) new symptomatic PE through 8 weeks, (b) filter migration (> 2cm), (c) filter embolization, (d) caval perforation (> 5mm), (e) symptomatic caval thrombosis, and (f) any other symptomatic filter-related complication requiring invasive intervention, or filter related death. 9 months
Secondary Incidence of new symptomatic PE through 8 weeks confirmed by CT angiography 8 weeks
Secondary Miller Score for symptomatic and asymptomatic PE Quantification of the occlusion of the pulmonary vascular bed from a PE. 9 months
Secondary Incidence of caval occlusion / thrombosis confirmed by CT cavogram 10 weeks
Secondary Incidence of IVC caval stenosis and occlusion confirmed by CT cavogram 9 months
Secondary Incidence of common femoral and iliac venous thrombosis ipsilateral to filter insertion site Detected on ultrasound. 2 weeks, 10 weeks, and 9 months
Secondary Incidence of DVT Detected on ultrasound. 2 weeks, 10 weeks, and 9 months
Secondary Incidence of major procedure-related or device-related adverse events 9 months
Secondary Incidence of major bleeding Major bleeding defined by International Society on Thrombosis and Haemostases. 9 months
See also
  Status Clinical Trial Phase
Recruiting NCT05050617 - Point-of-Care Ultrasound in Predicting Adverse Outcomes in Emergency Department Patients With Acute Pulmonary Embolism
Terminated NCT04558125 - Low-Dose Tenecteplase in Covid-19 Diagnosed With Pulmonary Embolism Phase 4
Not yet recruiting NCT06017271 - Predictive Value of Epicardial Adipose Tissue for Pulmonary Embolism and Death in Patients With Lung Cancer
Completed NCT03915925 - Short-term Clinical Deterioration After Acute Pulmonary Embolism
Completed NCT02502396 - Rivaroxaban Utilization for Treatment and Prevention of Thromboembolism in Cancer Patients: Experience at a Comprehensive Cancer Center
Recruiting NCT05171075 - A Study Comparing Abelacimab to Dalteparin in the Treatment of Gastrointestinal/Genitourinary Cancer and Associated VTE Phase 3
Completed NCT04454554 - Prevalence of Pulmonary Embolism in Patients With Dyspnea on Exertion (PEDIS)
Completed NCT03173066 - Ferumoxytol as a Contrast Agent for Pulmonary Magnetic Resonance Angiography Phase 1
Terminated NCT03002467 - Impact Analysis of Prognostic Stratification for Pulmonary Embolism N/A
Completed NCT02334007 - Extended Low-Molecular Weight Heparin VTE Prophylaxis in Thoracic Surgery Phase 1/Phase 2
Completed NCT02611115 - Optimizing Protocols for the Individual Patient in CT Pulmonary Angiography. N/A
Completed NCT01975090 - The SENTRY Clinical Study N/A
Not yet recruiting NCT01357941 - Need for Antepartum Thromboprophylaxis in Pregnant Women With One Prior Episode of Venous Thromboembolism (VTE) N/A
Completed NCT01326507 - Prognostic Value of Heart-type Fatty Acid-Binding Protein (h-FABP) in Acute Pulmonary Embolism N/A
Completed NCT00773448 - Screening for Occult Malignancy in Patients With Idiopathic Venous Thromboembolism N/A
Completed NCT00771303 - Ruling Out Pulmonary Embolism During Pregnancy:a Multicenter Outcome Study
Completed NCT00720915 - D-dimer to Select Patients With First Unprovoked Venous Thromboembolism Who Can Have Anticoagulants Stopped at 3 Months N/A
Completed NCT00780767 - Angiojet Rheolytic Thrombectomy in Case of Massive Pulmonary Embolism Phase 2
Completed NCT02476526 - Safety of Low Dose IV Contrast CT Scanning in Chronic Kidney Disease Phase 4
Completed NCT00816920 - Natural History of Isolated Deep Vein Thrombosis of the Calf