Clinical Trials Logo

Clinical Trial Summary

The aim of this study is to assess visual and refractive outcomes after Toric Trifocal lens implantation and visual outcomes after laser vision correction (LVC) - ReLex Smile to correct residual refraction after 6 months of Toric Trifocal (IOL) implantation.


Clinical Trial Description

The current state of the art for the correction of aphakia and presbyopia after lens extraction and refractive lensectomy is the implantation of multifocal intraocular lenses (IOL). In this study, the trifocal IOL types AT LISA TRI 839MP and AT LISA TRI TORIC 939MP (Carl Zeiss Meditec, Germany) were assessed. In this prospective non-randomized study patients with spherical hypermetropia of >4 D in combination with high astigmatism of >3.0 D were treated. The first group of 40 eyes of 20 patients underwent refractive lensectomy, followed by implantation of the diffractive trifocal IOL type AT LISA TRI 839MP (Carl Zeiss Meditec, Jena, Germany) and 6 months later SMILE surgery. In 40 eyes of 20 patients in the second group IOL type AT LISA TRI TORIC 939MP were implanted. All patients were adequately consulted preoperatively about this type of IOLs and they were verbally consented. The study is adherent to the tenets of the Declaration of Helsinki. All patient are between 20- 45 years old. The current study demonstrates that both the non-toric and toric versions of the trifocal IOL evaluated here provide excellent functional vision to patients, with good distance, intermediate and near uncorrected VA, a wide range of vision and good contrast sensitivity. Before SMILE,Yag-Laser capsulotomy should be performed on all patients, regardless of posterior capsule ossification, in pseudophakic patients with residual refraction. When the Yag-Laser is applied after the Smile, there will be a diopter change. Relex Smile surgery in pseudophakic patients with trifocal IOL was safe, effective, and predictable in a large cohort of patients. It is noteworthy that the decision for a treatment strategy (toric IOL or non-toric IOL with SMILE in s second step) should be made carefully, to select the appropriate method for the patient. During phaco surgey the positions of incisions should be determined according to the angle of the highest K value of the patient. For high astigmatic patients, toric trifocal IOL is highly effective. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04468022
Study type Interventional
Source Eye Hospital Pristina Kosovo
Contact
Status Completed
Phase N/A
Start date June 1, 2018
Completion date June 15, 2020

See also
  Status Clinical Trial Phase
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Completed NCT02423109 - Bilateral Dispensing Study of Fanfilcon A Toric Versus Enfilcon A Toric Lenses N/A
Completed NCT01392950 - Clinical Study of Clariti Monthly Contact Lens N/A
Withdrawn NCT00765960 - Evaluation of Outcomes Using the Amo Advanced CustomVue Ilasik Procedure
Completed NCT00520689 - Multipurpose Disinfecting Solution Compatibility With a Silicone Hydrogel Contact Lens Phase 3
Completed NCT05538182 - Zimbabwe Eyecare And Learning(ZEAL):Formative Research on Hyperopia and Educational Outcomes in Primary School Children N/A
Enrolling by invitation NCT05976750 - Air Optix® Night and Day® Aqua Daily Wear
Completed NCT02575911 - Accuracy of LASIK Flaps Created With the LenSx® Femtosecond Laser - A Pilot Study N/A
Completed NCT05735990 - Retrospective Clinical Investigation of the Safety and Performance of 640PM Trifocal IOL Implantation in Patients With Cataract and/or Ametropia (Hyperopia, Myopia) and/or Presbyopia
Withdrawn NCT03671096 - Safety and Efficacy of the Transform™ Corneal Allograft for Hyperopia Correction N/A
Recruiting NCT02279446 - Development of a Validated Chart for Intermediate Vision Assessment N/A
Completed NCT01951573 - Evaluation of a New Daily Disposable Multifocal Contact Lens Design N/A
Completed NCT02060539 - Multicenter Dispensing Study of Biofinity Lenses in Extended Range N/A
Completed NCT01467557 - Daily Disposable Performance of 1•DAY ACUVUE® TruEye™ and 1•DAY ACUVUE® MOIST® With LACREON® TECHNOLOGY
Completed NCT01228591 - Pilot Dispensing Evaluation of a Plus Power Lens N/A
Completed NCT03722784 - Evaluation of Silicone Hydrogel Daily Wear Contact Lenses for Up to One (1) Month of Daily Wear N/A
Completed NCT03688672 - Apioc Contact Lens Feasibility N/A
Completed NCT05741450 - A Clinical Comparison of Two Soft Contact Lenses N/A
Completed NCT01912781 - Safety and Efficacy Evaluation of a New Contact Lens Disinfecting Solution in Gas Permeable Contact Lens Wearers N/A