Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT06447389
Other study ID # KA-22056
Secondary ID
Status Active, not recruiting
Phase N/A
First received
Last updated
Start date December 15, 2022
Est. completion date June 15, 2024

Study information

Verified date June 2024
Source Hacettepe University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Dental-supported fixed partial dentures (FPDs) have long been a commonly preferred treatment method for the rehabilitation of teeth with excessive substance loss and for addressing existing tooth deficiencies. Crucial factor affecting the success and quality of FPDs is the marginal fit of the restoration. Marginal discrepancy refers to the vertical or horizontal gap between the restoration finish line and the preparation finish line. To achieve high marginal fit restorations, gingival retraction techniques are used with the aim of removing the marginal gingiva away from the finish line. Retraction cords are commonly used for this purpose nowadays. The aim of the study is to evaluate the effect of retraction cords on the preparation finish line and the marginal fit of produced restorations using direct digital measurement methods.


Description:

This study is designed to produce temporary bridges based on two supporting teeth, fabricated using an intraoral scanner, and to evaluate the marginal fit of these bridges based on two different digital measurements obtained with and without the use of retraction cord on the patient. The study will encompass patients with a single missing tooth in the posterior region of the lower or upper jaw, specifically involving the second premolar or first molar, planned for a three-unit tooth-supported fixed partial denture (SPP). Prior to preparation, patients will be examined for the assessment of the soft tissue around the teeth, and data collection will be conducted in accordance with the criteria outlined in Table-1, following the guidelines of the 2017 Consensus Report on the Classification of Periodontal and Peri-implant Diseases and Conditions regarding periodontal health and gingival diseases in healthy and reduced periodontium. Subsequently, the abutment teeth will be prepared stepwise using high-speed rotary instruments and diamond preparation burs to accommodate fixed restorations. The study groups will be formed considering the presence or absence of retraction application. The groups will be defined as Group I (No retraction cord) and Group II (Retraction cord present). In Group I, digital impressions will be taken directly in all patients without placing a retraction cord. In Group II, digital impressions will be taken in the same patients using a "000" knitted retraction cord and a single retraction cord technique. As part of this plan, digital impressions of the abutment teeth for the temporary bridge will be taken both before and after the application of the retraction cord. The temporary bridges fabricated from these impressions will then be evaluated intraorally. For each case included in the study, the .stl files from the initial impression for the restoration, the post-production impression, and the restoration itself will be superimposed and digitally analyzed using reverse engineering software. The depths of the preparation finish lines will be recorded using a probe. The recorded depths of the preparation finish lines and the amounts of marginal discrepancy of the restorations will be examined together. Based on the obtained data, the effect of the preparation finish line depth on the marginal fit of the restorations will be evaluated.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 32
Est. completion date June 15, 2024
Est. primary completion date August 15, 2023
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Voluntary participation after reading and understanding the informed consent form. - Over 18 years of age with no general health issues. - Presence of a single missing posterior tooth in the upper or lower jaw. - Possession of "clinical gingival health" in terms of periodontal condition ("Clinical gingival health of a healthy periodontium is defined as the absence of bleeding on probing, erythema, edema, symptoms, and no loss of bone or attachment.(17)) - Teeth with less than half of the tooth structure lost that do not require post-core treatment. Exclusion Criteria: - Failure to accept voluntary participation in the study after reading the informed consent form. - General health condition being unsuitable for prosthetic treatment.

Study Design


Related Conditions & MeSH terms


Intervention

Other:
retraction cordu (SURE-CORD®PLUS)
The evaluation of the effectiveness of retraction cords in determining the restoration margin in the fabrication of short fixed partial dentures for patients with missing teeth.

Locations

Country Name City State
Turkey Hacettepe University Faculty of Dentistry Department of Prosthodontics Ankara Altindag

Sponsors (1)

Lead Sponsor Collaborator
Hacettepe University

Country where clinical trial is conducted

Turkey, 

References & Publications (4)

Acar O, Erkut S, Ozcelik TB, Ozdemir E, Akcil M. A clinical comparison of cordless and conventional displacement systems regarding clinical performance and impression quality. J Prosthet Dent. 2014 May;111(5):388-94. doi: 10.1016/j.prosdent.2013.08.009. E — View Citation

Huang C, Somar M, Li K, Mohadeb JVN. Efficiency of Cordless Versus Cord Techniques of Gingival Retraction: A Systematic Review. J Prosthodont. 2017 Apr;26(3):177-185. doi: 10.1111/jopr.12352. Epub 2015 Sep 17. — View Citation

Mangano FG, Margiani B, Solop I, Latuta N, Admakin O. An Experimental Strategy for Capturing the Margins of Prepared Single Teeth with an Intraoral Scanner: A Prospective Clinical Study on 30 Patients. Int J Environ Res Public Health. 2020 Jan 7;17(2):392 — View Citation

Martins FV, Santana RB, Fonseca EM. Efficacy of conventional cord versus cordless techniques for gingival displacement: A systematic review and meta-analysis. J Prosthet Dent. 2021 Jan;125(1):46-55. doi: 10.1016/j.prosdent.2019.09.009. Epub 2020 Jan 31. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Digital analysis The comparison of the marginal fit of restorations fabricated from digital data with and without the use of a retraction cord was performed using reverse engineering software. The digital scans taken after preparation, the digital scans taken after restoration delivery, and the .stl files of the restorations were superimposed within the software and analyzed for marginal fit. 1.5 year
Secondary Probing dept Secondary data will be collected by measuring the step depths on the abutment teeth after preparation. These measurement points will be compared with the marginal fit of the temporary bridges at the same points, and the effect of step depth on marginal fit will be evaluated. 1.5 year
See also
  Status Clinical Trial Phase
Recruiting NCT06194838 - Clinical Outcomes With Non-Powered vs. Powered Prosthetic Knees by K2-level Amputees N/A
Completed NCT03570788 - HRQoL Among Patients Amputated Due to Peripheral Arterial Disease
Not yet recruiting NCT05548322 - Studies Into Touch in Healthy Humans to Provide Sensory Feedback in Prostheses N/A
Completed NCT02316262 - Targeted Reinnervation for Neuromas as a Means to Improve Prosthesis Control in Major Limb Amputation N/A
Recruiting NCT05870267 - Biomechanical Assessment of Load Applied on Residuum of Individuals With Limb Loss Fitted With a Prosthetic Limb
Completed NCT03498872 - Strategic Research Program 17 (VUB Funding) N/A
Completed NCT03530956 - Evaluation of a Novel Bionic Foot, AMPfoot 4+ N/A
Completed NCT04730492 - HErnias REparation After Kidney Transplantation Study
Recruiting NCT03625921 - Transfemoral Powered Foot and Physical Therapy Study N/A
Completed NCT05190354 - Post Market Clinical Protocol - Xtremity Polymer Prosthetic Socket System N/A
Completed NCT04272593 - Pattern Recognition Prosthetic Control N/A
Completed NCT05112679 - Limb Health and Socket Pressure in Response to Powered Ankle Protheses N/A
Completed NCT04595071 - Functional Outcomes of Voice Recognition Prosthesis N/A
Completed NCT03329326 - Comparison of Prosthetic Assessment Tools and Factors Influencing the Outcome
Terminated NCT03575975 - 3D X-ray Motion Analysis of Ankle-foot Motion After Total Ankle Arthroplasty
Completed NCT05048355 - Metabolic Cost of Walking With Passive vs. Powered Microprocessor Controlled Knees N/A
Completed NCT05124873 - Moisture Management Liner At-Home Evaluation N/A
Recruiting NCT05267639 - Clinical Outcomes With Passive MPKs vs. Powered Prosthetic Knees N/A
Completed NCT05749952 - Digital Weight Bearing Shape Capture Socket Technology N/A
Not yet recruiting NCT06052501 - 3D Evaluation of the Lip Support in a Full-arch Implant-supported Rehabilitations