Clinical Trials Logo

Clinical Trial Summary

The purpose of this study will be to evaluate the effect of direct and indirect pick up of the locator retentive caps and compare the clinical results with those of the manufacturer retentive force.


Clinical Trial Description

Patient selection: For this study, 30 patients were selected from the clinic of Prosthodontic Department, Faculty of Dentistry, Mansoura University. According to pick up technique for the locator retentive caps, the overdentures will be classified into two groups as follows; Group1: The retentive caps will be picked up by indirect method on the cast then by the direct method Group2: The retentive caps will be picked up in the patient by the direct method first then by the indirect method. For both groups, the clinical retention will be measured after using pink and blue retentive inserts respectively. All implants were inserted using computer-guided implant surgery and conventional loading protocol was used. Evaluation methods The clinical retention of each insert will be calibrated as regards the manufacturer's value. Also, the laboratory retention will be assessed for the two groups and calibrated as regards the manufacturer's value. Measurements will be done immediately, three and six months after each overdenture insertion. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05289752
Study type Interventional
Source Mansoura University
Contact
Status Completed
Phase N/A
Start date August 30, 2021
Completion date March 16, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT05062733 - SEBBIN Round, Anatomical and Biconvex Gluteal Implants
Completed NCT03469687 - Symax International Study N/A
Completed NCT05112679 - Limb Health and Socket Pressure in Response to Powered Ankle Protheses N/A
Recruiting NCT05883553 - Epithesis Versus Prosthesis in Post-phalloplasty Transgender Patients. N/A
Completed NCT06080815 - Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion N/A
Active, not recruiting NCT06332482 - Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration N/A
Completed NCT06116877 - Effect of Adding Zirconium Oxide Nanoparticles to Printable Implant Overdenture N/A
Active, not recruiting NCT06040385 - Effect of Geometric Modifications of Implant Scan Bodies N/A
Recruiting NCT04968470 - SEBBIN Silicone Gel-filled Testicular Implants
Recruiting NCT05642390 - SEBBIN INTEGRITY Round Implants
Recruiting NCT06228859 - Evaluation of Locator Versus TITACH Attachment for Mandibular Overdentures. N/A
Completed NCT05321589 - Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis N/A
Enrolling by invitation NCT06050213 - Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture? N/A
Recruiting NCT05220553 - A Sensorimotor Prosthesis for the Upper Limb N/A
Recruiting NCT03595423 - SPAnish Aortic VALVE Multicentric Study
Completed NCT05290766 - Two Versus Four Implant-supported Fixed Full-arch Prosthesis N/A
Completed NCT05912127 - All on Four Versus All on Three Implant Treatment Concepts N/A
Recruiting NCT06321042 - Evaluation of the Clinical Outcomes of the Total Knee ps Prosthesis Implanted With the Use of Inertial Sensors
Recruiting NCT05097820 - Prospective Observational Study on SEBBIN Silicone Gel-filled Testicular Implants
Completed NCT06187181 - Hyoid Displacement During Swallowing Function for Completely Edentulous Subjects N/A