Clinical Trials Logo

Clinical Trial Summary

This is a non-blind randomized clinical trial to determine the efficacy of the TurnCare Q2 System for the prevention of sacral region (sacral, coccygeal, and buttocks) pressure ulcers. TurnCare Q2 System has 2 main components: 1. An Inflatable Skin Perfusion Enhancement Surface and 2. An Adaptive Pressure Controller. The Skin Perfusion Enhancement Surface has a patented design that accommodate human anatomy in the sacra region. The Adaptive Pressure Controller is powered by APSAR technology that provides patient specific pressure relieve in the sacral region.


Clinical Trial Description

This study is a prospective, non-blinded randomized clinical trial. The study protocol and the consent form were approved by the IRB at the study institution. Consecutive adult patients admitted to the hospital with Braden Scale scores of 16 or less who did not meet exclusion criteria were consented and enrolled in the study. All in-patients were either scheduled admissions or were admitted through the emergency department. Upon admission, risk assessments for pressure ulcers and total body surveys were performed by the hospital staff. A Braden Scale score was determined for each patient by the hospital staff according to standard hospital protocol. Both the control group and the treatment group patients received standard care for pressure ulcer prevention according to hospital protocols, policies and guidelines. Standard pressure ulcer prevention measures for this facility include a methodology referred to as a "S.K.I.N." Bundle (S-surface selection, K-keep turning, I-incontinence management, N-nutrition.) This successful pressure ulcer prevention initiative was developed within the parent health organization and standardized throughout its 131 hospitals. In accordance with the S.K.I.N. Bundle, all patients admitted to the study hospital were repositioned every two hours, provided incontinence care, and given aggressive nutritional management as indicated. All care measures were documented in the hospital's electronic medical record (EMR) system. After obtaining informed consents, patients in the treatment group had the Q2 System placed on their beds and chairs. Perfusion enhancement surfaces were placed directly on hospital beds under the fitted bed sheets and were secured to bed frames with disposable Velcro straps. A disposable "chux" pad and lifter sheet were placed on top of the fitted sheets as is standard in most hospital settings. Adaptive pressure controllers were secured to bed footboards or attached to bases of IV poles. Specific settings for each patient were entered into the controllers. The controller settings entered included patient body weight and bed position (degrees of incline). The bed position included a bed setting (30 degrees incline) and a chair setting (90 degrees incline). When applicable, a second perfusion enhancement surface was placed on a hospital chair so that the Q2 solution could be utilized in a "sitting mode" while patients were sitting in hospital chairs. The Q2 Systems remained in continuous operation during the trial period. Patient skin did not contact any part of the Q2 system directly at any time. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03107143
Study type Interventional
Source TurnCare Inc.
Contact
Status Active, not recruiting
Phase N/A
Start date June 15, 2016
Completion date May 1, 2017

See also
  Status Clinical Trial Phase
Not yet recruiting NCT04266808 - Interactive Telehealth for Wheelchair Users N/A
Completed NCT04168450 - Evaluation of Wheelchair In-Seat Activity Tracker N/A
Completed NCT04890678 - The Use of a Fully Automated Pulsating Support System (CuroCell® A4 CX20) in Pressure Ulcer Prevention and Treatment N/A