Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04189224
Other study ID # CR-6372
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date November 15, 2019
Est. completion date March 10, 2020

Study information

Verified date March 2021
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study is a randomized, single-masked, crossover clinical trial. There are two study lenses. Each lens will be dispensed for 3 ± 1 days and then an optimization visit will occur. The final lens pair will be dispensed for 12 ± 2 days and the follow-up on the final lens pair will occur. The second study lenses will then be fit and the above sequence repeated.


Recruitment information / eligibility

Status Completed
Enrollment 46
Est. completion date March 10, 2020
Est. primary completion date March 10, 2020
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 40 Years to 70 Years
Eligibility Inclusion Criteria: - Potential subjects must satisfy all of the following criteria to be enrolled in the study: 1. The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 2. The subject must appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. The subject must be at least 40 years of age and not greater than 70 years of age at the time of consent. 4. Subjects must own a wearable pair of spectacles if required for their distance vision. 5. The subject must be an adapted soft contact lens wearer in both eyes (i.e. worn lenses a minimum of 2 days per week for at least 8 hours per wear day, for 1 month or more duration). 6. The subject must either already be wearing a presbyopic contact lens correction (e.g., reading spectacles over contact lenses, multifocal or monovision contact lenses, etc.) or if not respond positively to at least one symptom on the "Presbyopic Symptoms Questionnaire" (Appendix E). 7. The subject's distance spherical equivalent refraction must be in the range of +1.25 D to +3.75 D in each eye. 8. The subject's refractive cylinder must be =0.75 D in each eye. 9. The subject's ADD power must be in the range of +0.75 D to +2.50 D. 10. The subject must have distance best corrected visual acuity of 20/20-3 or better in each eye. Exclusion Criteria: - Potential subjects who meet any of the following criteria will be excluded from participating in the study: 1. Currently pregnant or lactating. 2. Any active or ongoing ocular or systemic allergies that may interfere with contact lens wear. 3. Any active or ongoing systemic disease, autoimmune disease, or use of medication, which may interfere with contact lens wear. This may include, but not be limited to, diabetes, hyperthyroidism, Sjögren's syndrome, xerophthalmia, acne rosacea, Stevens- Johnson syndrome, and immunosuppressive diseases or any infectious diseases (e.g. hepatitis, tuberculosis). 4. Any previous, or planned, ocular or intraocular surgery (e.g. radial keratotomy, PRK, LASIK, lid procedures, cataract surgery, retinal surgery, etc.). 5. A history of amblyopia, strabismus or binocular vision abnormality. 6. Use of any of the following medications within 1 week prior to enrollment: oral retinoid isotretinoin (e.g. Accutane), oral tetracyclines, oral phenothiazines, oral/topical/inhaled anticholinergics, systemic/topical corticosteroids. 7. Use of any ocular medication, with the exception of rewetting drops. 8. History of herpetic keratitis. 9. History of irregular cornea. 10. History of pathological dry eye. 11. Participation in any contact lens or lens care product clinical trial within 30 days prior to study enrollment. 12. Employee or immediate family member of an employee of clinical site (e.g., Investigator, Coordinator, Technician). 13. Any known hypersensitivity or allergic reaction to Optifree®Replenish® multipurpose care solution, sodium fluorescein or non-preserved rewetting drop solutions. 14. Clinically significant (Grade 2 or greater) corneal edema, corneal vascularization, corneal staining, tarsal abnormalities or bulbar injection, or any other corneal or ocular abnormalities which would contraindicate contact lens wear. 15. Entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions. 16. Any current ocular infection or inflammation. 17. Any current ocular abnormality that may interfere with contact lens wear.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
JJV Investigational Multifocal Contact Lens
TEST
1-Day Acuvue® Moist Brand Multifocal Contact Lens
CONTROL

Locations

Country Name City State
United States ProCare Vision Centers Granville Ohio
United States Frazier Vision Inc. Jacksonville Texas
United States Maitland Vision Center Maitland Florida
United States Advanced Eyecare Raytown Missouri

Sponsors (1)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Binocular Contact Lens-Corrected Visual Performance Under Standard High Contrast Bright The contact lens-corrected visual performance on logMAR scale was evaluated binocularly under high luminance high contrast, dim luminance high contrast and high luminance low contrast conditions at 4 meters (distance), 64 cm (intermediate) and 40 cm (near) using ETDRS/reduced Guillon-Poling charts. A value of 0.0 logMAR equates to 20/20 vision on a Snellen Scale. Lower values indicate better visual performance. The average visual performance was reported for each lens type and distance. 2-Week Follow-up
Primary Binocular Contact Lens-Corrected Visual Performance Under Standard High Contrast Dim With Goggles The contact lens-corrected visual performance on logMAR scale was evaluated binocularly under high luminance high contrast, dim luminance high contrast and high luminance low contrast conditions at 4 meters (distance), 64 cm (intermediate) and 40 cm (near) using ETDRS/reduced Guillon-Poling charts. A value of 0.0 logMAR equates to 20/20 vision on a Snellen Scale. Lower values indicate better visual performance. The average visual performance was reported for each lens type and distance. 2-Week Follow-up
Primary Binocular Contact Lens-Corrected Visual Performance Under Standard Low Contrast Bright The contact lens-corrected visual performance on logMAR scale was evaluated binocularly under high luminance high contrast, dim luminance high contrast and high luminance low contrast conditions at 4 meters (distance), 64 cm (intermediate) and 40 cm (near) using ETDRS/reduced Guillon-Poling charts. A value of 0.0 logMAR equates to 20/20 vision on a Snellen Scale. Lower values indicate better visual performance. The average visual performance was reported for each lens type and distance. 2-Week Follow-up
Secondary Overall Vision Scores Overall vision scores were assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, aged 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. 2-Week Follow-up
Secondary Overall Comfort Scores Overall comfort scores were assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, aged 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. 2-Week Follow-up
Secondary Number of Grade 3 or Higher Slit Lamp Findings Slit Lamp Findings (SLF) were assessed using a biomicroscope and was graded using the FDA grading scale (Grade: 0, 1,2, 3 and 4) with grade 0 represents the absence of findings and 1 to 4 representing successively worse findings (i.e. Grade 1 = trace, Grade 2 = Mild, Grade 3 = moderate and Grade 4 = severe). Slit Lamp Findings were assessed at the 2-Week Follow-up. SLF is a binary response where Y=1 for at least one Grade 3 or 4 slit lamp finding. The number of eyes with SLF with grade 3 or higher by lens was reported. 2-Week Follow-up
Secondary Proportion of Subjects That Reported Ocular Symptoms Subject reported ocular symptoms were assessed using a questionnaire at the 2-week follow-up. Subjects were asked if they experienced any of the following symptoms: Burning/Stinging, Itchiness/Scratchiness, Dryness, Lens Awareness, Grittiness/Foreign Body Sensation, Redness, Irritation/Discomfort, Cloudy/Blurry/Hazy, Variable Vision and Other; using the scale of: None, Mild, Moderate and Severe. The proportion of subjects that reported symptoms (Mild, Moderate and Severe) was reported for each lens type. 2-Week Follow-up
See also
  Status Clinical Trial Phase
Completed NCT05326607 - Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia N/A
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Completed NCT05495971 - Extended Depth of Focus Contact Lenses for Presbyopia N/A
Completed NCT05464732 - Vivity IOL: Emmetropia Compared to Monovision. N/A
Recruiting NCT06045299 - Evaluation of the Efficacy and Safety of LNZ101 and LNZ100 for the Presbyopia Phase 3
Active, not recruiting NCT04151550 - Safety & Efficacy of the Laser Scleral Microporation Procedure (Philippines) N/A
Not yet recruiting NCT05506553 - Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision N/A
Completed NCT02554396 - Evaluation of the Efficacy and Safety of PRX-100 in the Treatment of Early to Moderate Presbyopia Phase 2
Completed NCT02214797 - Dispensing Study to Assess Visual Performance of Prototype Contact Lenses N/A
Completed NCT02235831 - DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance N/A
Enrolling by invitation NCT01443585 - Clinical Evaluation of a Progressive Addition Lens (PAL) N/A
Completed NCT01591499 - Clinical Evaluation of Biofinity Multifocal Compared With Air Optix Aqua Multifocal and With PureVision Multifocal N/A
Completed NCT04983589 - A Study to Assess Safety and Efficacy in Participants Age 40 to 55 With Presbyopia (Old Eye) Who Receive AGN-190584 in Both Eyes Twice Daily Phase 3
Completed NCT02740010 - The Visual Performances of a Progressive Multifocal Intraocular Lens With Extended Depth of Focus
Recruiting NCT05796453 - Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix N/A
Completed NCT02516306 - A Study to Evaluate the Safety and Efficacy of EV06 Ophthalmic Solution in Improving Vision in Subjects With Presbyopia Phase 1/Phase 2
Completed NCT05359380 - The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
Not yet recruiting NCT04522427 - Study of Presbyopia-correcting Intraocular Lenses in Eyes With Previous Corneal Refractive Surgery N/A
Completed NCT03688425 - Comparison of Clinical Outcomes POD L GF vs POD F GF in Asian Eyes N/A
Recruiting NCT06053463 - Evaluation of Soft Multifocal Lenses in Presbyopic Previous Contact Lens Wearers N/A