Cyber Physical System for Smart Corrective Eyeglasses
A high-performance smart eyeglasses system with integrated sensing, actuation, control and data collection is being developed at the University of Utah. These smart eyeglasses use tunable lenses and integrated sensor technologies to correct blurred vision caused due to a major age-related condition called presbyopia.The objective of this study is to test this smart system on patients suffering from presbyopia aged 45 and above. The researchers intend to study the effect of these smart eyeglasses by qualitatively investigating the patient's visual acuity with this smart system. The results of this study and subsequent research have the potential to lead to major lifestyle improvements and better treatment for millions of presbyopic patients that are constrained by the limitation of current corrective eyeglass technologies. There are two main sources of fairly well understood problems that lead to presbyopia and loss of the eye focusing function. The adaptive eyeglasses used in these tests do not fix any of the internal eye problems. They just compensate externally for the loss of the eye focusing function caused by presbyopia. As such, the investigators intend to evaluate our system's effectiveness in terms of the sharpness of the perceived images.
Eye defects occur when the eye cannot focus images from the outside world. This results in blurred vision, which sometimes is so severe that it causes visual impairment. Among the many vision defects, presbyopia is an inevitable, irreversible, universal age-related condition where the crystalline lens in the eye loses its accomodation orthe ability to change the optical power. This defect occurs as a natural result of aging and will ultimately affect any person reaching advanced enough age. It was estimated in 2005 that over 1 billion people worldwide suffered from presbyopia, with approximately 400 million suffering from near vision loss due to the lack of correction technologies. The most inexpensive and commonly used tools to correct vision errors are fixed power eyeglasses, which haven't seen any improvement since the mid-1800s. Conventional eyeglasses are an ancient piece of technology which originated in Europe's middle ages. A major drawback of such eyeglasses is that they can only correct the lack of accomodation at a particular object distance, since they use fixed power lenses. As a result, conventional eyeglasses can produce sharp images for objects located either far away or near the observer but not both. Bifocal, multifocal and progressive lenses can partially alleviate vision defects, but at the expense of reduced and fragmented field of view. As an example, multifocal lenses have different lens powers in different regions of the lens. With such lenses, it is not possible to see objects clearly over the entire visual field. Further, the effectiveness of conventional eyeglasses is not monitored outside the optometrist's office. The proposed smart eyeglasses system uses a combination of large-aperture fluidic lenses, ultra-light actuators, object distance sensors and embedded control, communications and computing electronics to continuously produce sharp and focused images at any object range. They can also collect the behaviour and characteristics of the observer's eyes to gauge the effectiveness of the technology and adapt to observer's visual degradation over age. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05326607 -
Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia
|
N/A | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Completed |
NCT05495971 -
Extended Depth of Focus Contact Lenses for Presbyopia
|
N/A | |
Completed |
NCT05464732 -
Vivity IOL: Emmetropia Compared to Monovision.
|
N/A | |
Recruiting |
NCT06045299 -
Evaluation of the Efficacy and Safety of LNZ101 and LNZ100 for the Presbyopia
|
Phase 3 | |
Active, not recruiting |
NCT04151550 -
Safety & Efficacy of the Laser Scleral Microporation Procedure (Philippines)
|
N/A | |
Not yet recruiting |
NCT05506553 -
Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision
|
N/A | |
Completed |
NCT02554396 -
Evaluation of the Efficacy and Safety of PRX-100 in the Treatment of Early to Moderate Presbyopia
|
Phase 2 | |
Completed |
NCT02235831 -
DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance
|
N/A | |
Completed |
NCT02214797 -
Dispensing Study to Assess Visual Performance of Prototype Contact Lenses
|
N/A | |
Enrolling by invitation |
NCT01443585 -
Clinical Evaluation of a Progressive Addition Lens (PAL)
|
N/A | |
Completed |
NCT01591499 -
Clinical Evaluation of Biofinity Multifocal Compared With Air Optix Aqua Multifocal and With PureVision Multifocal
|
N/A | |
Completed |
NCT04983589 -
A Study to Assess Safety and Efficacy in Participants Age 40 to 55 With Presbyopia (Old Eye) Who Receive AGN-190584 in Both Eyes Twice Daily
|
Phase 3 | |
Completed |
NCT02740010 -
The Visual Performances of a Progressive Multifocal Intraocular Lens With Extended Depth of Focus
|
||
Recruiting |
NCT05796453 -
Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix
|
N/A | |
Completed |
NCT02516306 -
A Study to Evaluate the Safety and Efficacy of EV06 Ophthalmic Solution in Improving Vision in Subjects With Presbyopia
|
Phase 1/Phase 2 | |
Completed |
NCT05359380 -
The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
|
||
Not yet recruiting |
NCT04522427 -
Study of Presbyopia-correcting Intraocular Lenses in Eyes With Previous Corneal Refractive Surgery
|
N/A | |
Completed |
NCT03688425 -
Comparison of Clinical Outcomes POD L GF vs POD F GF in Asian Eyes
|
N/A | |
Recruiting |
NCT06053463 -
Evaluation of Soft Multifocal Lenses in Presbyopic Previous Contact Lens Wearers
|
N/A |