Laryngoscopy Clinical Trial
Official title:
Comparison of Dexmedetomidine and Midazolam as Intramuscular Premedication for Suspension Laryngoscopy
Many studies have been conducted for the feasibility of using dexmedetomidine as premedication. However, bradycardia and hypotension frequently occurred following the premedication with dexmedetomidine, either via intramuscular or intravenous route. This is particularly true when using a high dose of dexmedetomidine: a intramuscular dose over 2 μg•kg-1 or a intravenous dose over 1 μg•kg-1 can elicit marked decreases in heart rate and mean arterial blood pressure. Subsequent studies using high-dose dexmedetomidine further revealed the potential impact of its detrimental haemodynamic profile on clinical outcomes. Most studies using high-dose dexmedetomidine were predominantly adopted with the dose-finding study performed by Aho and colleague, whom reported that 2.5 μg•kg-1 dose of intramuscular dexmedetomidine was comparably sedative and anxiolytic to 0.08 mg•kg-1 midazolam. However, few investigations have addressed the clinical effects of low-dose dexmedetomidine as premedication. Considering modern anaesthesia has advanced a long way towards eliminating the routine need for a deep preoperative sedation. It has, therefore, become desirable to asses dexmedetomidine as an effective premedication using a moderate sedative dose to minimize its undesired hemodynamic effects. We set a prospective study to compare the sedative, haemodynamic, adjuvant anaesthetic effects and patient's satisfaction of low-dose dexmedetomidine (1μg•kg-1) with midazolam (0.03 mg•kg-1), the most commonly used premedication, used as an intramuscular injective administration in patients undergoing suspension laryngoscopic surgery under general anaesthesia.
n/a
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03277872 -
NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
|
N/A | |
Completed |
NCT05515107 -
The Laryngoscopic View With C-MAC Videolaryngoscope Miller Blade Lifting the Epiglottis or the Vallecula in Children
|
N/A | |
Recruiting |
NCT03426579 -
Correlation Between Sedation Depth Monitoring and Reflexes During Intravenous Anesthesia With Dexmedetomidine and Remifentanil in Children Undergoing Direct Laryngoscopy for Surgical Procedures
|
||
Recruiting |
NCT06037915 -
Airway Interventions During Intravenous Anesthesia in Children Undergoing Direct Laryngoscopy for Surgical Procedures Using High Flow Nasal Versus Low Flow Oxygen. A Pilot Study.(Flowkid)
|
Phase 4 | |
Completed |
NCT00803751 -
A Comparison of the Infant Truview EVO2 Video Laryngoscope and the Macintosh Laryngoscope in Pediatric Patients
|
N/A | |
Completed |
NCT03470116 -
Comparison Between the MacGrath MAC Videolaryngoscope and the MacIntosh Laryngoscope for Oro-tracheal Intubation for Patients With Less Than 2 Criteria of Difficult Intubation in Elective Surgery.
|
N/A | |
Completed |
NCT04701762 -
Endotracheal Intubation Using Videolaryngoscopy Versus Conventional Direct Laryngoscopy
|
N/A | |
Completed |
NCT04259021 -
The Voice Analysis as a Preoperative Prediction Method of a Difficult Airway
|
||
Recruiting |
NCT04620434 -
Improvement of the Glottic View by Video Laryngoscope
|
||
Recruiting |
NCT00926718 -
The Effect of Rocuronium on the Response of Composite Variability Index (CVI) to Laryngoscopy
|
N/A | |
Completed |
NCT03981042 -
Comparison Between the Neuromuscular Blockade Onset Monitoring and the Expectation of a Fixed Delay After Curarization on the Quality of Laryngoscopy During Intubation in Elective Surgery (MONITURARE)
|
N/A | |
Completed |
NCT05859542 -
Place of the Video-laryngoscope in Learning Intubation by Simulation
|
||
Terminated |
NCT03472118 -
High Flow Oxygen in Patients Undergoing Suspension Laryngoscopy Under General Anesthesia
|
N/A | |
Recruiting |
NCT06149338 -
The Rate of Successful Intubation and the Required Time for Intubation, Using Vie Scope and Macintosh Laryngoscope Will be Compared, in Order to Evaluate the Efficacy of Vie Scope in Comparison With Macintosh in Expected Easy Airways.
|
N/A | |
Completed |
NCT00992628 -
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
|
N/A | |
Completed |
NCT03599687 -
Soiled Airway Tracheal Intubation and the Effectiveness of Decontamination by Paramedics
|
||
Completed |
NCT03709979 -
Effect Of Position On Laryngeal Visualisation With The C-Mac Videolaryngoscope
|
N/A | |
Not yet recruiting |
NCT06226532 -
Effect of Lidocaine Sprayed for Attenuating Hemodynamic Response During Laryngoscopy and Intubation
|
Phase 4 | |
Completed |
NCT01685320 -
Force and Pressure Distribution Using Macintosh and GlideScope Laryngoscopes in Normal Airway: an in Vivo Study
|
N/A | |
Completed |
NCT03464929 -
Learning Curves for Airtraq Versus King Vision Laryngoscopes
|