View clinical trials related to Polyps.
Filter by:The study shall mainly help to better evaluate the performance the APDS device and secondly it may help to assess the potential of the future alpha version of the device to be a useful and effective for the detection of colon Polyps.
The purpose of this study is to examine the role of an automatic polyp detection software (henceforth referred to as the research software) as a support system during colonoscopy; a procedure during which a physician uses a colonoscope or scope, to look inside a patient's rectum and colon. The scope is a flexible tube with a camera-to see the lining of the colon. The research software is used to aid in the detection of polyps (abnormal tissue growths in the wall of the colon and adenomas (pre-cancerous growths) during colonoscopy. The research software used in this study was programmed by a company in Shanghai, which develops artificial intelligence software for computer aided diagnostics. The research software was developed using a large repository (database or databases) of polyp images where expert colonoscopists outlined polyps and suspicious lesions. The software was subsequently developed and validated using several databases of images and video to operate in near real-time or within minutes of photographing the tissue. It is intended to point out polyps and suspicious lesions on a separate screen that stands behind the primary monitor during colonoscopy. It is not expected to change the colonoscopy procedure in any way, and the physician will make the final determination on whether or not to biopsy or remove any lesion in the colon wall. The research software will not record any video data during the colonoscopy procedure. In the future, this software may help gastroenterologists detect precancerous areas and decrease the incidence of colon cancer in the United States.
In this non-randomized controlled trial, a semi-random group of Dutch endoscopist receive an oral training about the significance of serrated polyps. The primary aim of this training is to improve the endoscopist's awareness of the significance of serrated polyps, ultimately leading to increased detection. In addition, a random group of endoscopists that will not receive this training will be used as a reference group. Data will be collected as part of routine care within the Nationwide Dutch Bowel cancer screening program. The serrated polyp detectionrate of each endoscopist will be extracted from anonymized data that will be prospectively collected as part of routine care within the Dutch Nationwide bowel cancer screening program. Data will be anonymized and provided by Rijksinstituut voor Volksgezondheid en Milieu (RIVM) and ScreenIT.
Colonoscopy is the standard of care for the detection of colorectal polyps and adenoma, and colorectal cancer detection. Despite a meticulous evaluation of the colonic mucosa during colonoscopy, a substantial number of colorectal polyps might be missed and colorectal cancer might not be prevented. Previous studies described a 12-28% of miss-rate for all polyps, a 31% for hyperplastic polyps and 6-27% for adenomas, with a higher miss rate noted for smaller polyps. The lesion missing rate depends on several factors, such as the location on difficult areas to be evaluated with conventional colonoscopes (the proximal side of the ileocecal valve, haustral folds, flexures or rectal valves), a flat shape, an inadequate bowel preparation and inadequate endoscopy technique, a time-limited colonoscope withdrawal. If the standard 140º angle of view colonoscope is used approximately 13% of the colonic surface is unevaluated. The incorporation of colonoscopes with a 170-degree wide angled could improve adenoma detection rate. The introduction of high definition (HD) colonoscopes and visual image enhancement technologies, such as narrow band imaging (NBI, Olympus America, Center Valley, PA), I-SCAN™ (Pentax Medical, Montvale, NJ) and Fuji Intelligent Chromo-Endoscopy (FICE™, Fujinon Endoscopy, Wayne, NJ) have improved the lesion characterization; however, several studies have failed to prove an increase in the adenoma detection rates. The Third Eye Retroscope (Avantis Medical Systems, Sunnyvale, CA) is a disposable retrograde viewing device advanced through the accessory channel of a standard colonoscope. It allows retrograde viewing behind colonic folds and flexures simultaneously with the forward view of the colon. Although it shows an increase in the adenoma detection rate by 11%-25%, it has many disadvantages. First, it requires a separate processor and the device is disposable, increasing the cost of the procedure. Second, it occupies the working channel of the colonoscope, limiting the ability to suction. Third, if a polyp is detected, the viewing device has to be removed in order to perform the polypectomy. Fourth, the optic is not high definition and finally, the endoscopist has to get used to visualizing and processing two simultaneous video streams from the colonoscopy and from the retroscope device.
The study shall mainly help to better evaluate the performance the APDS device and secondly it may help to assess the potential of the future alpha version of the device to be a useful and effective for the detection of colon Polyps.
Prevalence of aspirin-exacerbated respiratory disease (AERD) is 16% amongst patients suffering from chronic rhinosinusitis with nasal polyps (CRSwNP). The mechanisms underlying the observed dysregulation of pro and anti-inflammatory pathways in AERD are still not fully understood. To address this and also to identify potential factors characterizing the disease the investigators plan to prospectively collect blood samples, nasal secretions as well as nasal biopsies from allergic, non-allergic and AERD patients suffering from CRSwNP. Initially, polyps of aforementioned patients will be subjected to RNA sequencing analysis using microarray technology. Once distinct factors are identified in nasal polyp tissue, their presence will be assessed in nasal secretions and serum of the respective patients to investigate their potential role as biomarkers. Furthermore presence of these parameters will be confirmed in situ in biopsies by confocal microscopy. Knowledge about factors differently upregulated in polyp tissue from AERD may contribute to a better understanding of the underlying mechanism of the disease.
This will be a prospective randomized controlled trial comparing CO2 insufflation and WE in terms of right colon combined adenoma miss rate (AMR) and hyperplastic polyp miss rate (HPMR) by tandem inspection. It will be a single-site study conducted in Taiwan.
This clinical trial is being conducted to compare the efficacy and safety of two standard methods of polypectomy,Conventional Endoscopic Mucosal Resection(EMR)and Underwater Endoscopic Mucosal Resection(UEMR),for small colorectal polyps.
Rationale: Diminutive colorectal polyps (1-5mm in size) have a high prevalence and very low risk of harbouring cancer. Current practice is to send all these polyps for histopathological assessment by the pathologist. If an endoscopist would be able to correctly predict the histology of these diminutive polyps during colonoscopy, histopathological examination could be omitted and practise could become more time- and cost-effective. Studies have shown that prediction of histology by the endoscopist remains dependent on training and experience and varies greatly between endoscopists, even after systematic training. Computer aided diagnosis (CAD) based on convolutional neural networks (CNN) may facilitate endoscopists in diminutive polyp differentiation. Up to date, studies comparing the diagnostic performance of CAD-CNN to a group of endoscopists performing optical diagnosis during real-time colonoscopy are lacking. Objective: To develop a CAD-CNN system that is able to differentiate diminutive polyps during colonoscopy with high accuracy and to compare the performance of this system to a group of endoscopist performing optical diagnosis, with the histopathology as the gold standard. Study design: Multicentre, prospective, observational trial. Study population: Consecutive patients who undergo screening colonoscopy (phase 2) Main study parameters/endpoints: The accuracy of optical diagnosis of diminutive colorectal polyps (1-5mm) by CAD-CNN system compared with the accuracy of the endoscopists. Histopathology is used as the gold standard.
Colonoscopy screening is proven to reduce mortality rates for colorectal cancer, which relies on early detection and removal of colonic polyps. AmplifEYE is a FDA-approved device with a row of flexible detection arms attached to the tip of colonoscope which can separate colonic folds during scope withdrawal and is believed to improve polyp detection. Real-life clinical data on this relatively new device is lacking and this study aims to compare the adenoma and polyp detection rates in AmplifEYE-assisted colonoscopy versus standard colonoscopy.