Clinical Trials Logo

Clinical Trial Summary

Endobronchial ultrasound (EBUS) is a technique that uses ultrasound along with bronchoscope to visualize airway wall and structures adjacent to it. Pneumothorax is a known complication from EBUS procedure. To rule out a Pneumothorax after the procedure, a Chest -X-ray is usually done. Point-of-care sonography has emerged as an invaluable tool in the assessment of patients with both traumatic and non-traumatic dyspnea. Multiple studies involving bedside ultrasound has shown that a pneumothorax can easily be ruled out if pleural sliding sign or B lines are visualized on lung ultrasonography; the accuracy of lung ultrasound in ruling out pneumothorax approach computed tomography and exceed plain radiography. Preforming a lung ultrasound using the EBUS bronchoscope tip as a way to rule out pneumothorax has never been described previously. If this is possible it will obviate the need of getting a Chest -X-ray and decrease the dose of radiation that the patient is exposed to. In this study we will demonstrate that the feasibility of using the transducer of the EBUS Bronchoscope to perform bedside lung ultrasound to rule out pneumothorax.


Clinical Trial Description

The use of ultrasound in diagnosis and treatment of patients has been well-established for many decades. The use of thoracic ultrasonography is a fairly new and rapidly evolving field. The interface between the ultrasound probe and chest wall can produce artifacts that can be useful in diagnosing a pneumothorax. In one prospective study the utility of ultrasound was compared to chest X-ray and CT-scan by trauma surgeon (1). Their results demonstrate that ultrasound was more sensitive than chest X-ray to identify early pneumothorax. The study also demonstrated that 63% of pneumothoraxes diagnosed were occult and would have been later diagnosed on CT chest. In these critical situations where is subtle pneumothorax can be missed, a bedside ultrasound has been proven to accelerate the diagnosis and thus treatment. Similarly another prospective study noted that up to 76% of all traumatic pneumothoraxes were missed by standard AP chest X-ray, when interpreted by trauma team (2). This number was significantly higher than a retrospective study in which 55% of pneumothoraxes were missed on AP chest films reviewed by radiologist (3). The sensitivity of ultrasound in detecting pneumothorax has been demonstrated in multiple studies to be similar to CT-scan, which is considered to be gold standard for the detection of pneumothorax (4, 5). Visualization of normal pleural lung sliding is itself sufficient to exclude pneumothorax , if lung sliding is not present the finding of B lines( vertical lines), which usually originate from the lung parenchyma will also exclude the possibility of pneumothorax at the interspace in question, since the lung parenchyma cannot be visualized if there is air interposed between the pleura and the lung. Endobronchial ultrasound (EBUS) is considered an integral component of diagnosis of indeterminate mediastinal lymph nodes, masses and peripheral pulmonary nodules. EBUS is minimally invasive, safe and highly accurate (6). According to current estimates that incidence if complications associated with EBUS is between 1-1.5% (6, 7). Major complications are associated with needle aspirations. The incidence of pneumothorax was found to be 3.3% in one retrospective analysis (8), with 31% of patients requiring chest tube eventually for treatment of pneumothorax. Post-procedure chest-X-rays are commonly performed to rule out pneumothorax. Based on current data chest-X-rays are considered suboptimal for diagnosis of pneumothorax and can also expose patients to undue radiation. The EBUS probe contains a small ultrasound through which ultrasound images of various structure i.e. lymph nodes, ventricles, pulmonary vasculature can be visualized. Ruling out pneumothorax via lung ultrasound using EBUS probe has never been described. If this is possible, it avoids the need of obtaining post-procedure Chest-X-rays thus decreasing the dose of radiation exposure and prevent time delays for the arrival of chest-x-rays. In this study we will demonstrate the feasibility of using the transducer of the EBUS Bronchoscope to perform bedside lung ultrasound to rule out pneumothorax. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02907866
Study type Observational
Source University of Oklahoma
Contact Houssein Youness, MD
Phone 405-271-6173
Email houssein-youness@ouhsc.edu
Status Recruiting
Phase
Start date September 2016
Completion date December 2025

See also
  Status Clinical Trial Phase
Recruiting NCT06022081 - Lung Ultrasound Versus Chest Radiography for Detection of Pneumothorax N/A
Terminated NCT03034421 - Prevention of Pneumothorax Following Endoscopic Valve Therapy in Patients With Severe Emphysema N/A
Completed NCT02232841 - Electrical Impedance Imaging of Patients on Mechanical Ventilation N/A
Completed NCT02619591 - Comparison Of Chest Ultrasound Techniques To Identify Clinically Significant Pneumothorax N/A
Recruiting NCT05342675 - Effect of Rapid Rollover on Pneumothorax After CT-Guided Lung Biopsy N/A
Recruiting NCT05910112 - Prospective Data Collection on Clinical, Radiological and Patient Reported Outcomes After Pleural Intervention
Completed NCT03656406 - Effect of Lateral Positioning on Bronchial Cuff Pressure of Left-sided Double-lumen Endotracheal Tube During Thoracic Surgery
Active, not recruiting NCT06075836 - AI Assisted Detection of Chest X-Rays
Recruiting NCT03728491 - Education and Training Competences in Thoracic Ultrasound N/A
Recruiting NCT05407974 - Pleurectomy Versus Pleural Abrasion in Patients With Spontaneous Pneumothorax N/A
Completed NCT01670942 - Hypobaria and Traumatic Pneumothorax N/A
Terminated NCT00969423 - Chronic Pain After Video-assisted Thoracoscopic Surgery (VATS) Surgery for Pneumothorax N/A
Completed NCT05904574 - Effectiveness of the Autologous Blood Patch Method in Lung Biopsies
Completed NCT03327688 - Point-of-care Ultrasound in Finland N/A
Completed NCT05963945 - Multi-Reader Retrospective Study Examining Carebot AI CXR 2.0.21-v2.01 Implementation in Everyday Radiology Clinical Practice
Completed NCT05222568 - Effect of the Minimum Bronchial Cuff Volume of Left-sided Double-lumen Endotracheal Tube for One-lung Ventilation on the Change of the Bronchial Cuff Pressure During Lateral Positioning in Thoracic Surgery
Not yet recruiting NCT05121233 - Local Anesthesia Versus Combined Local Anesthesia With Single Dose Analgesia on Pain Control During Thoracic Ultrasound Guided Procedures Phase 4
Completed NCT03064659 - Driving Pressure And EFL in Adult Cardiac Surgery N/A
Recruiting NCT02090205 - Mechanical Ventilation During Cardiac Surgery N/A
Active, not recruiting NCT01855464 - Wedge Resection or Parietal Pleurectomy for the Treatment of Recurrent Pneumothorax (WOPP) N/A