Clinical Trials Logo

Clinical Trial Summary

To validate the benefits of recognizing asymmetric lung disease like atelectasis and pneumothorax in neonatal respiratory distress syndrome using electrical impedance tomography


Clinical Trial Description

To quantify the changes in regional lung air content associated with the variations of the respiratory support settings, the following approach will be used. The changes in local air content will be determined in the selected EIT region of interest (ROI) in terms of a change in local average lung density and relative impedance change with respect to a reference air content. - TimePeriod 1 (t1): The reference lung air content will be measured once the asymmetric lung disease is identified on chest x-ray. - TimePeriod 2 (t2): A post-lung disease EIT measurement will be obtained at 6-24 hours later or immediately after therapy (i.e. chest tube placement or needle decompression). Eligible infants with confirmed asymmetric lung disease (atelectasis or pneumothorax) by radiographic images requiring no respiratory support or on mechanical support or nCPAP therapy of 5-8 cm H20 achieved with a ventilator, an underwater "bubble" system, or a variable-flow device will be enrolled. All of these methods of providing the therapy are done with FDA approved devices currently used in the NICU. EIT data will be acquired using The LuMon Monitor-Neo, GUI software 1.0.x.x/TIC software 1.6.x.xxx (SenTec, Landquart, Switzerland). The EIT system will be placed at the subject's bedside to collect EIT measurements: Ventilation distribution%, changes in regional aeration in arbitrary units (AU), dependent and non-dependent silent spaces. A data acquisition cart will also be placed at the subject's bedside to collect hemodynamic and respiratory parameters measurements including: Heart rate (HR), blood pressure (BP), respiratory rate (RR), fraction of inspired oxygen (FiO2), transcutaneous carbon dioxide (TcCO2), and peripheral oxygen saturation (SpO2) via bedside monitoring devices. The LuMon belts for neonates are disposable single-patient use belts that are adhesive-free and consists of 32 electrodes which are sized to the infant's chest circumference, generally at the 4th - 6th rib. Warmed NeoContactAgent (ingredients: Aqua, Glycerol, Sodium chloride) will be applied to the belt before placing on the infant. The embedded position sensor permits the LuMon System to measure and display the patient's position. The soft and expandable closure band prevents the chest from being constrained by the belt and, consequently, prevents restrictions to breathing and increased work of breathing. EIT measurements and data will be collected on each timeperiods (t1 and t2) for approximately 15-30 minutes on invasive or non-invasive ventilatory support. The EIT measurements may be repeated on an eligible participant if a reoccurrence of a confirmed asymmetric lung disease, atelectasis or pneumothorax, is identified on a radiographic image. EIT is currently not used for patient care management at SMBHWN. EIT's use for patient care management is purely experimental. EIT, when used solely for physiologic data collection, its use is not subject to 21 CFR 50, 21 CFR 56, or 21 CFR 812. Data collection via EIT will occur when the subject is in a quiet, sleeping state, and can be accomplished in a convenient time period when care givers or parents are not interacting with the subject. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04848727
Study type Observational
Source Sharp HealthCare
Contact
Status Completed
Phase
Start date August 6, 2021
Completion date June 7, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05180955 - The Role of Clamping Before Removal of a Pneumothorax Drain Connected to a Digital Drainage System. N/A
Active, not recruiting NCT05077111 - A Comparative Study Between Regional Anesthesia in Thoracoscopes and the Conventional General Anesthesia Phase 4
Recruiting NCT05230420 - Urine Bag Usage Versus Chest Drain Clamping After Lung Resection Surgeries N/A