Pleural Effusion Clinical Trial
— FLEXPLEUROfficial title:
Comparison of Diagnostic Yield and Complication of Medical Thoracoscopy Using Flexible Bronchoscope Versus Semi-Rigid Pleuroscope Among Hospitalized Patients With Pleural Effusion
Pleural effusion is a common problem in hospital patients. It may arise from a wide range of diseases. There is a multitude of recognised causes of pleural effusion, and in addition, other pleural conditions such as pleural thickening and pneumothorax represent a significant burden to the healthcare system and to patients. However, the diagnosis of this condition may sometimes be difficult. In pleural effusions undiagnosed by thoracocentesis, closed pleural biopsy increases the yield by ∼10% and 40%, respectively, in malignant and tuberculous pleural effusions, whereas the diagnostic yield of thoracoscopy is ∼93% in both malignant and tuberculous pleural effusions. Hence, medical thoracoscopy (MT) (pleuroscopy) is the gold standard in the diagnosis of pleural effusion and it is indicated when less invasive tests have failed. MT is a procedure in which the pleura is directly and visually examined. An endoscope is inserted into the intercostal space by creating a pneumothorax with an incision through the chest wall. The pleural space and its lining can be inspected and therapeutic interventions performed. There are two different techniques that can be performed for diagnostic and therapeutic thoracoscopy. One method recommends a single-entry site, the use of a usually 9-mm rigid thoracoscope (or of a semi-rigid/semi-flexible 7-mm pleuroscope) with a working channel for accessory instruments and an optical biopsy forceps, both performed under local anaesthesia. The other method requires two entry sites: one for a 7-mm trocar for the examination telescope, and the other for a 5-mm trocar for accessory instruments including the biopsy forceps, and is usually performed with conscious sedation or general anaesthesia. In the trained hands of a pulmonologist, MT is a safe and effective procedure for diagnosing and treating multiple pleural diseases. Valsecchi et al reported a pathological diagnostic yield of 71% over a span of 30 years in around 2000 patients. The unfamiliarity of the pulmonary physician with the rigid instrument and familiarity with the flexible bronchoscope has led various investigators to attempt thoracoscopy even with a fibreoptic bronchoscope. The use of a flexible fibreoptic instrument to examine the pleural space was reported by Senno et al in the 1970s in the United States. Studies showed that flexible bronchoscope, when used as a thoracoscope, maintains a clear optical field by allowing concurrent suctioning, which is analogous to the suction techniques used during flexible bronchoscopy and better views at the apex and paravertebral gutters.This method is, therefore, considered to be useful for surgeons or physicians with experience in chest drainage and flexible bronchoscopy as well as safe and well tolerated with a minimal degree of discomfort and expense.
Status | Recruiting |
Enrollment | 150 |
Est. completion date | December 12, 2024 |
Est. primary completion date | December 12, 2024 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 100 Years |
Eligibility | Inclusion Criteria: 1. Age 18 years and above 2. Subjects admitted to Faculty of Medicine UKM during the study period and underwent a single MT with flexible bronchoscopy or semi-rigid pleuroscopy. Exclusion Criteria: 1. Age < 18 years. 2. Patients with incomplete data 3. Patients' medical record that cannot be retrieved. |
Country | Name | City | State |
---|---|---|---|
Malaysia | National University of Malaysia | Kuala Lumpur | Wilayah Persekutuan |
Lead Sponsor | Collaborator |
---|---|
National University of Malaysia |
Malaysia,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | To compare the diagnostic yield (in percentage) using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | Subjects underwent medical thoracoscopy and the purpose is to compare the diagnostic yield, complication and duration of MT using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | between October 2017 to October 2022 | |
Secondary | To compare the rate of complication (in percentage) using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | Subjects underwent medical thoracoscopy and the purpose is to compare the rate of complication using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | between October 2017 to October 2022 | |
Secondary | To compare the duration of procedure (in minutes) using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | Subjects underwent medical thoracoscopy and the purpose is to compare the duration of procedure using flexible bronchoscopy versus semi-rigid pleuroscopy in hospital patients with pleural effusion. | between October 2017 to October 2022 | |
Secondary | To determine the predictors of diagnostic yield of flexible bronchoscope in hospital patients with pleural effusion | Subjects underwent medical thoracoscopy and the purpose is to determine the predictors of diagnostic yield of flexible bronchoscope in hospital patients with pleural effusion | between October 2017 to October 2022 |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04159831 -
A Study to Evaluate LTI-01 in Patients With Infected, Non-draining Pleural Effusions
|
Phase 2 | |
Recruiting |
NCT02891642 -
Liquid Biopsy With Immunomagnetic Beads Capture Technique for Malignant Cell Detection in Body Fluid
|
||
Completed |
NCT02232841 -
Electrical Impedance Imaging of Patients on Mechanical Ventilation
|
N/A | |
Completed |
NCT02045641 -
Pleural and Pericardial Effusion Following Open Heart Surgery
|
N/A | |
Completed |
NCT01948076 -
Evaluation of a Pocket-Sized Ultrasound Device As an Aid to the Physical Examination
|
N/A | |
Completed |
NCT01416519 -
Physiotherapy Technique Decreases Respiratory Complications After Cardiac Operation
|
N/A | |
Completed |
NCT01560078 -
Efficacy Study of Thrice Weekly Directly Observed Treatment Short-Course Regimen in Tubercular Pleural Effusion
|
N/A | |
Completed |
NCT04891705 -
Point of Care Ultrasound Lung Artificial Intelligence (AI) Validation Data Collection Study
|
||
Recruiting |
NCT05759117 -
Prospective Evaluation of Patients With Pleural Effusion
|
||
Recruiting |
NCT05910112 -
Prospective Data Collection on Clinical, Radiological and Patient Reported Outcomes After Pleural Intervention
|
||
Completed |
NCT03896672 -
Clinical Implementation of the Use of Positive Pressure in Chest Drainage
|
N/A | |
Active, not recruiting |
NCT06075836 -
AI Assisted Detection of Chest X-Rays
|
||
Recruiting |
NCT03728491 -
Education and Training Competences in Thoracic Ultrasound
|
N/A | |
Completed |
NCT03535883 -
The Safety of Thoracentesis, Tunneled Pleural Catheter, and Chest Tubes in Patients Taking Novel Oral Anti-Coagulants
|
||
Not yet recruiting |
NCT03260088 -
Evaluation Of Pleural Effusion At Assiut University Hospital
|
N/A | |
Completed |
NCT03296280 -
Evaluation of Implementation of a National Point-of-Care Ultrasound Training Program
|
||
Completed |
NCT03661801 -
Novel Pleural Fluid, Biopsy and Serum Biomarkers for the Investigation of Pleural Effusions
|
||
Completed |
NCT01778270 -
Not Invasive Monitoring of Pleural Drainage
|
N/A | |
Terminated |
NCT00402896 -
Malignant Pleural Effusion With ZD6474
|
Phase 2 | |
Recruiting |
NCT00103766 -
Alteplase for Treatment of Empyema and Complicated Parapneumonic Effusion
|
N/A |