Plaque, Dental Clinical Trial
Official title:
Clinical Evaluation of an Electric and a Manual Toothbrush in Removal of Dental Plaque by Intraoral Imaging Systems
The study aimed to evaluate the efficacy of manual and electric toothbrush on dental plaque removal by using various intraoral imaging systems. Thirty healthy individuals using the same type of toothbrush for at least 2 years participated in the study. 12 teeth of each individual, including upper and lower anteriors, were examined. Group 1 including volunteers who used to use manual toothbrushes (MT) started to use an electric toothbrush (ET) and Group 2 including volunteers who used to use an ET and started to use a MT for 1 month with the same daily brushing routines. Following the clinical intraoral examination, plaque (PI) and gingival index (GI) measurements were performed 5 hours after brushing. The GI was evaluated through Sillness&Löe Gingival Index. The PI was evaluated according to Quigley and Hein's Plaque Index criteria and was scored clinically on visual inspection and digital imaging systems including FluoreCam, DSLR Camera, D-Light Pro, Smile Lite MDP, iTero Element Flex. The data was evaluated under p<0.005 significant level.
Patient and teeth selection criteria Ten healthy individuals between the ages of 20 and 30 years with no systemic disease, restoration or caries, and whom have the criteria for using the same type of toothbrush for 2 years (15 of them use manual toothbrushes and 15 of them use electric toothbrushes) participated in the study. 12 teeth of each individual, including upper and lower anteriors, were examined. The researchers supplied the volunteers with a manual toothbrush (Oral-B toothbrush Pro Expert Complete, Procter&Gamble, USA), an electronic toothbrush with replacement head (Oral-B Cross Action toothbrush replacement head, Procter&Gamble, USA), and a toothpaste (Oral-B Professional Toothpaste and Enamel Pro Repair Toothpaste, Procter&Gamble, USA). Changing the Type of Toothbrush The first group (Group 1) includes volunteers who used to use manual toothbrushes and started to use an electric toothbrush for 1 month with the same daily brushing routine. The second group (Group 2) includes volunteers who used to use an electric toothbrush and started to use a manual toothbrush for 1 month with the same daily brushing routines. Plaque and gingival index measurements Following the clinical intraoral examination of the volunteers in both groups, plaque and gingival index measurements were performed 5 hours after brushing. Regarding the plaque detection, a special 3-tone plaque staining product, Tri Plaque ID gel (GC Corp., Tokyo, Japan), was used to demonstrate the quantity and quality of the plaques on teeth' surfaces. The staining gel was applied onto buccal surfaces of upper and lower anterior teeth. The plaque and gingival indexes were both evaluated initially, 1 week, and 1 month after the toothbrush changes. The plaque index was evaluated according to Quigley and Hein's Plaque Index criteria. The gingival index was evaluated through Sillness & Löe Gingival Index and was scored clinically on visual inspection, digitally on dental photographs and digital imaging systems. Quigley ve Hein Plaque Index 0 -> No plaque 1 -> Flecks of stain of the gingival margin 2 -> Definitive line of plaque on gingival margin 3 -> Gingival third of surface 4 -> Two-thirds of surface 5 -> Greater then 2/3rd of the surface Sillness & Löe Gingival Index 0 -> Healthy gingiva 1 -> Slight change in color and mild inflammation, no bleeding 2 -> Redness, moderate inflammation, bleeding on probing/pressure 3 -> Marked redness, severe inflammation, spontaneous bleeding Monitorization with intraoral dental photography The stained and unstained photographs of the teeth were taken initially, one week, and one month after the toothbrush changes. A camera (Nikon D7100), a macro lens (Nikon, 105mm VR macro lens), and a TTL dual macro flashlight (Meike MK-MT24N) was used for the DSLR photography. The camera parameters were set to ISO 400, diaphragm f/25, and shutter speed 1/125. A mobile dental photography device, Smile Lite MDP, was also used in combination with a smart phone (iPhone 12 Mini, Apple Inc, CA, USA) as an alternative photography technique. CP filter was used for all the photographs taken with Smart Lite MDP. The photographs with and without CP were taken without calibrating the white balance (WB) in auto white balance (AWB) mode. Additionally, a led curing unit D-Light Pro was used in detection mode in combination with the DSLR camera to enhance the visualization of the stained plaque. ISO was set at 1600 and diaphragm f/11 for photography with the D-Light Pro. The quantity of the plaque on tooth surfaces was scored through the photographic analysis. Monitorization with digital imaging systems The stained and unstained measurements were performed initially, one week, and one month after the toothbrush changes by using FluoreCam and iTero Flex devices. After the plaque was stained, it was distinguished from healthy enamel tissue in terms of both color and fluorescence properties. FluoreCam device was used as one of the methods to determine the amount of dental plaque visually and numerically in this study. The stained plaque areas were automatically marked and recorded in the FluoreCam software, simultaneously with the visualization of fluorescence images of upper and lower anterior teeth on the screen. Size and intensity values of stained plaque were obtained from FluoreCam software. Size values represent the area of the plaque, meanwhile intensity values demonstrate the amount of mineral loss and were always represented as a negative number. Decreasing values in intensity (e.g., from -15 to -10) signify that the lesion (mineral content) had slightly improved. The images of the anterior teeth were also taken by using a real-time intraoral scanner, iTero Element Flex (AlignTech, Carlstadt, USA) to digitalize and distinguish the plaque dye to provide clear 3D images and better visual assessment. Plaque measurements and gingival index scores at initial, one week, and one month after the toothbrush change; for Group 1 and Group 2 were evaluated statistically using Mann Whitney U test. Additionally, the images obtained by the FluoreCam device were compared on the system software and evaluated statistically using Mann Whitney U and Wilcoxon tests. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05825742 -
Regular Home Use of Dual-light Photodynamic Therapy on Oral Health in Adolescents Undergoing Fixed Orthodontic Treatment
|
N/A | |
Completed |
NCT06098976 -
The Effectiveness of the Water Jet Device in Removing Dental Plaque Around Orthodontic Braces in Adolescents
|
N/A | |
Recruiting |
NCT05470023 -
Imaging-based Assessment of Oral Biofilm and Gingival Health
|
N/A | |
Completed |
NCT05363956 -
Antiplaque Efficacy of Two Novel Commercially Available Herbal Toothpastes.
|
Phase 1 | |
Completed |
NCT04137393 -
The Effect of Brushing With Salvadorapersica (Miswak) Sticks on Salivary Streptococcus Mutants and Plaque Level in Children: A Clinical Trial
|
Phase 3 | |
Completed |
NCT03219840 -
Cetylpyridium Chloride (CPC) Based Chewing Gum and Gingivitis
|
Phase 4 | |
Recruiting |
NCT05384132 -
Novel Dental Gel as an Adjunct to Scaling and Root Planing
|
N/A | |
Completed |
NCT05361590 -
Impact of Regular Home Use of Lumoral Dual-light Photodynamic Therapy on Plaque Control and Gingival Health
|
N/A | |
Active, not recruiting |
NCT06079307 -
Effect of Oxygenated Mouthwash and Mouth Foam
|
N/A | |
Completed |
NCT04794452 -
Dental Plaque Removal Evaluation and Comparison of Kid's Battery-Operated Toothbrush and Manual Toothbrush
|
N/A | |
Recruiting |
NCT06164496 -
Evaluation of the Effectiveness of Different Toothbrushes in Children
|
N/A | |
Completed |
NCT04794439 -
Plaque Removal Efficacy of Four Dentifrices Following a Single Brushing
|
Phase 2 | |
Completed |
NCT06126445 -
Single Brushing Plaque Removal Efficacy of a Battery-powered Toothbrush and a Manual Toothbrush
|
N/A | |
Not yet recruiting |
NCT06331442 -
The Effect of Photodynamic Therapy on Plaque in Orthodontic Patients
|
N/A | |
Completed |
NCT04003493 -
LifE Style, Nutrition and Oral Health in Care Givers (LENTO)
|
N/A | |
Completed |
NCT06353165 -
Anti-bacterial Clinical Study on Teeth, Tongue, Cheek, Gum, and Saliva
|
Phase 3 | |
Not yet recruiting |
NCT04713566 -
Comparative Clinical Effects of Salvadora Persica Oral Rinse And A Phenolic Commercial Mouth Wash On Human Oral Health
|
N/A | |
Completed |
NCT04681885 -
Evaluation of Toothbrush Bristles in Plaque Reduction
|
N/A | |
Not yet recruiting |
NCT06430060 -
The Clinical Investigation of Colgate Dual Zinc Toothpaste as Compared to Colgate Cavity Protection Toothpaste in Controlling Established Plaque and Gingivitis
|
Phase 3 | |
Not yet recruiting |
NCT06453005 -
Comparative Evaluation of SMART Hall Technique vs. Conventional SS Crown in Primary Molars: A Randomized Clinical Trial
|
N/A |