Clinical Trials Logo

Clinical Trial Summary

To evaluate the safety and efficacy of the Complete SE SFA Stent System in the treatment of de novo and/or restenotic lesions or occlusions in the Superficial Femoral Artery (SFA) and/or Proximal Popliteal Artery (PPA) in subjects with symptomatic Peripheral Artery Disease (PAD).


Clinical Trial Description

The Complete Self-Expanding (SE) SFA Stent is designed to be a permanent implant. It is cut from a nickel titanium alloy (Nitinol) tube and consists of a series of segments each connected to the next in a unique pattern to allow for flexibility and vessel conformability. Each segment consists of two struts and a crown (Figure 1). It is designed to produce optimal luminal diameter and increased scaffolding, and to maintain luminal patency. ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00814970
Study type Interventional
Source Medtronic Endovascular
Contact
Status Completed
Phase N/A
Start date November 2008
Completion date December 2013

See also
  Status Clinical Trial Phase
Recruiting NCT05335525 - Post-market Clinical Investigation of the Angio-Seal™ VIP VCD (ANGIO-SEAL CLOSE)
Active, not recruiting NCT01903044 - Safety and Efficacy of Autologous Bone Marrow Stem Cells for Lower Extremity Ischemia Treating Phase 1/Phase 2
Completed NCT02271529 - Zilver PTX Delivery System N/A
Completed NCT02228564 - BARD® Study of LIFESTREAM™ Balloon Expandable Covered Stent Treating Iliac Arterial Occlusive Disease N/A
Recruiting NCT02054871 - RCT to Evaluate the Renal Protective Effects of Remote Ischaemic Preconditioning in Peripheral Angioplasty N/A
Completed NCT00822172 - Evaluation of Cilostazol in Combination With L-Carnitine Phase 4
Completed NCT00574782 - Evaluation of the Efficacy of Rosuvastatin in Daily Practice in Untreated High Risk Patients (CHALLENGE) N/A
Completed NCT00029991 - Extract of Ginkgo Biloba (EGB 761) and Vascular Function Phase 1/Phase 2
Completed NCT01355406 - Evaluation of Safety and Efficacy of the FlexStent® Femoropopliteal Self-Expanding Stent System N/A
Recruiting NCT05804097 - Does Increasing Oxygen Nurture Your Symptomatic Ischemic Ulcer Sufficiently? Phase 4
Recruiting NCT03638115 - The VaSecure BTK Study N/A
Active, not recruiting NCT03241459 - Safety and Efficacy of the SurVeil™ Drug-Coated Balloon N/A
Active, not recruiting NCT01661231 - Study to Determine the Performance of the Astron and Pulsar-18 Stents in Europe N/A
Completed NCT01722877 - JetStream (JS) Atherectomy in Femoropopliteal In-Stent Restenotic Lesions N/A
Completed NCT01444378 - Absolute Pro® MOMENTUM™ N/A
Completed NCT00753337 - The ACTIVE (Use of the Assurant® Cobalt Iliac Stent System in the Treatment of Iliac Vessel Disease) Study N/A
Completed NCT00593385 - Atrium iCAST Iliac Stent Pivotal Study N/A
Completed NCT00538226 - Evaluation of the Effect of the Flowaid Device in Increasing Local Circulation in the Leg Phase 1
Recruiting NCT00385385 - RESTORE-IT-Study of Rifalazil in Chlamydia Pneumoniae Seropositive Patients With a History of Atherosclerotic Disease Phase 2
Completed NCT00392509 - ALD-301 for Critical Limb Ischemia, Randomized Trial Phase 1/Phase 2