Clinical Trials Logo

Clinical Trial Summary

The aim of the present study is to evaluate the potential benefit of the adjunctive use of an air-polishing device in the treatment of peri-implantitis as compared to mechanical infection control alone. Following establishment of adequate patient-performed infection control, 80 patients diagnosed with moderate/severe peri-implantitis at ≥1 implant will be randomized to one of two groups. Non-surgical and, if required, surgical therapy will be carried out by experienced operators in three clinical centers and the mechanical instrumentation (control group) will be supplemented by the use of air-polishing with erythritol powder (AirFlow Master, EMS, Nyon, Switzerland) in the test group. The primary outcome assessed is "pocket closure" (ie probing pocket depth ≤5 mm & absence of profuse bleeding on probing) after non-surgical (6 months) and surgical therapy (18 months). Secondary outcomes include changes of clinical signs of soft tissue inflammation, adverse events and patient-reported outcome measures. Outcomes of non-surgical therapy will be evaluated at 3 and 6 months. Sites with remaining pathology at 6 months will be subjected to surgical therapy.


Clinical Trial Description

The project will be conducted as a two-armed randomized controlled clinical trial of 5-year duration in three clinical centers. 80 systemically healthy patients diagnosed with moderate/severe peri-implantitis at ≥1 implant will be enrolled. Upon enrolment, all patients will receive instructions in oral hygiene measures until adequate plaque control has been established (Plaque Index ≤20%). If required, supraconstructions will be adjusted to facilitate adequate oral hygiene measures. Thereafter, study participants will be randomized into two groups, stratified for smoking (yes/no) and number of implants in need of treatment (single/multiple). The control group will be subjected to professionally administered mechanical infection control including the use of hand instruments and polishing cups aiming at the removal of all supra-mucosal soft and hard deposits from the target sites. In the test group the aforementioned treatment will be supplemented by the use of an air-polishing device (AirFlow Master, EMS, Nyon, Switzerland) with a specially designed nozzle for sub-mucosal application (PerioFlow Handpiece, EMS, Nyon, Switzerland). Following local anesthesia, the instrument will be used sub-mucosally at all aspects (ie mesial, distal, buccal, lingual) of the affected implant(s) at a power setting reduced to 60% and with a erythritol powder (14 mikrometer, AirFlow Plus Powder, EMS, Nyon, Switzerland). The handpiece will be guided in a circular motion in a corono-apical direction not in contact with the implant surface. Instrumentation time will be limited to 5 seconds at each aspect. Implant-supported supraconstructions will not be removed for the non-surgical treatment. Patients are recalled two weeks later for assessment of patient-experienced outcomes, professional supramucosal cleaning and reinforcement of oral hygiene. Peri-implant soft tissues will be evaluated at three months. Implant sites with remaining signs of pathology (PPD ≥6 mm and presence of BOP at ≥3 aspects per implant will be subjected to re-treatment according to the initial allocation. The clinical evaluation will be repeated at 6 months. In case of residual signs of pathology, affected sites will be subjected to surgical therapy of peri-implantitis within the subsequent 4 weeks. Full thickness flaps will be elevated and inflamed tissues will be removed. Mineralized deposits on the implant surfaces will be removed with titanium-coated curettes. Surface decontamination will be performed using a rotating titanium brush under irrigation with saline. No bone recontouring of bony walls is intended. Flaps will be sutured to the level of the bone and sutures will be removed after 2 weeks. Implant-supported supraconstructions will be removed for the surgical intervention, if possible. Maintenance therapy will be provided at 9 and 12 months and based on individual needs during the subsequent follow-up. A renewed evaluation will be performed at 12 and 18 months. Long-term assessments will be carried out annually from years 3 to 5. Should any implant site present with signs of disease progression (increase of PPD >2 mm and additional bone loss >1 mm compared to baseline) at any of the follow-up examinations, the implant will be exited from the study and appropriate additional therapy will be provided. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04847648
Study type Interventional
Source Göteborg University
Contact
Status Enrolling by invitation
Phase N/A
Start date October 14, 2021
Completion date October 1, 2027

See also
  Status Clinical Trial Phase
Completed NCT05332327 - Comparison of the Accuracy of Different Periodontal Probes for Peri-implant Pocket Registration
Enrolling by invitation NCT06063876 - Experimental Peri-implant Mucositis on Implant Sites That Were Previously Treated With or Without Implantoplasty N/A
Completed NCT04249024 - Peri-implantitis, Comparing Treatments 970 nm Laser and Mucosal Flap Surgery N/A
Withdrawn NCT03624257 - Comparing Two Treatment Modalities of Peri-implantitis - Blue Laser (445 nm) and Conventional Flap Surgery N/A
Completed NCT03018795 - Ozone Therapy as an Adjunct to the Surgical Treatment of Peri-implantitis N/A
Completed NCT02375750 - Treatment of Peri-implantitis Lesions by Using Biomaterial N/A
Completed NCT03157193 - Effect of Hyaluronic Acid on Perimplantitis Phase 4
Enrolling by invitation NCT02575274 - Peri-Implantitis Surgical Treatment an RCT Study Phase 2/Phase 3
Completed NCT04833569 - ICG-PDT, Periimplantitis, Diabetes Mellitus Phase 1
Not yet recruiting NCT04337645 - Resective Surgical Treatment of Peri-implantitis. N/A
Enrolling by invitation NCT06033859 - Incidence of Bleeding on Probing as an Indicator of Peri-Implant Disease Progression
Active, not recruiting NCT06390124 - Reconstructive Therapy of Peri-implantitis With PDGF-BB (Gem-21) Phase 4
Enrolling by invitation NCT05675241 - Characterizing the Inflammation Around Dental Implants
Recruiting NCT04983758 - 20-year Implant Survival in Periodontally Healthy and Compromised Patients
Not yet recruiting NCT04323540 - Treatment of Peri-implantitis With or Without Simultaneous Soft Tissue Augmentation N/A
Completed NCT04874467 - Influence of Keratinized Mucosa on Dental Implants With Mucositis N/A
Completed NCT04769609 - Reconstructive Surgical Therapy of Peri-implantitis
Completed NCT05724706 - An Evaluation of Salivary Oxidant and Antioxidant Levels in Peri-implant Health and Disease
Completed NCT04559841 - Regenerative Surgical Treatment of Peri-implantitis Using Nanobone With or Without Simvastatin N/A
Recruiting NCT05906810 - Impact of Non-surgical Periodontal Therapy in the Improvement of Early Endothelial Dysfunction in Subjects With Peri-implantitis and Peri-implant Mucositis N/A