Patient Satisfaction Clinical Trial
Official title:
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
Verified date | November 2023 |
Source | Mansoura University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The aim of this crossover clinical study was the evaluation and comparison of masticatory performance and patient satisfaction for patients rehabilitated with conventional heat cured acrylic resin and 3D printed mandibular implant overdentures retained with bar attachment. it was concluded that 3D printed implant overdenture showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdenture.
Status | Completed |
Enrollment | 16 |
Est. completion date | August 10, 2023 |
Est. primary completion date | July 30, 2023 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 50 Years to 70 Years |
Eligibility | Inclusion Criteria: - adequate bone quantity [classes 1-3 according to [Lekholm and Zarb] of the mandible in the lateral incisor and first premolar regions to receive 4 implants - adequate restorative space [12-15 mm from the mucosa of the mandibular ridge to the occlusal plane- Class I according to Ahuja and Cagna 23 for bar supported implant overdenture. This was verified by direct measurement of old denture - Angel's class I maxillo-mandibular relationship. Exclusion Criteria: - include systemic diseases that contraindicate implant placement - irradiation of the head and neck region - chemotherapy within the past 3 years - bone metabolic diseases as uncontrolled diabetes mellitus - smoking habit |
Country | Name | City | State |
---|---|---|---|
Egypt | Mansoura University, Faculty of dentistry | Mansoura |
Lead Sponsor | Collaborator |
---|---|
Mansoura University |
Egypt,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Chewing efficiency | Chewing efficiency was assessed using the previously documented two-color mixing ability test (colorimetric method) as follow: Two samples were prepared from two colored chewing gums. Patients were asked to keep the gum sample intraorally for one minute then start to chew it for 5, 10, 20, 30 and 50 strokes respectively. Five samples were used for the tests, the samples were spat into clear plastic bags. All samples were evaluated after flattening to wafers of 1 mm thickness. scanned by Digital scanner from both sides stored in Adobe Photoshop® format (psd). Then the color range tool and histogram function were used to pick out the unmixed white parts of the image. Then the ratio of Unmixed Fraction (UF) was computed using the following formula: (Pixels white side a + Pixels white side b) - 2× Pixels of scale / 2 × Pixels all. As a reference scale, a scanned piece of unmixed gum was copied in each image | at time of insertion of prosthesis T(0), 3 months after insertion T(3). | |
Primary | Patient satisfaction | The eight core of McGill Denture Satisfaction Questionnaire (MDSQ) items were used to record patient satisfaction with their mandibular complete removable denture. One question concerns overall satisfaction with existing prostheses, whereas the other seven questions refer to specific aspects that may influence overall satisfaction: ease of cleaning; ability to speak; comfort; aesthetics/appearance; and denture stability; chewing ability; chewing function. Respondents provided answers on a 100-mm visual analogue scale. Patients were encouraged to respond to the survey questionnaire after functioning with each type of denture for 3-months. | at time of insertion of prosthesis T(0), 3 months after insertion T(3). |
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04079543 -
NPO and Patient Satisfaction in the Cath Lab
|
N/A | |
Enrolling by invitation |
NCT05053958 -
Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.
|
N/A | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT04774562 -
The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery
|
N/A | |
Terminated |
NCT04604340 -
Radial Versus Femoral Arterial Access for Cerebral Angiography in Adolescents
|
N/A | |
Recruiting |
NCT04539210 -
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
|
N/A | |
Completed |
NCT02924974 -
Spinal Morphine in Robotic Assisted Radical Prostatectomy
|
Phase 4 | |
Completed |
NCT01052415 -
POL and Access Intervention to Reduce HIV Stigma Among Service Providers in China
|
N/A | |
Recruiting |
NCT06044103 -
Patient-controlled Sedation During Repair of Obstetric Perineal Lacerations
|
Phase 4 | |
Not yet recruiting |
NCT05670080 -
Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair?
|
N/A | |
Completed |
NCT06114524 -
Effect of Binaural Beats on Level of Anxiety and Toleration in Patients Undergoing Upper Gastrointestinal Endoscopy Without Sedation
|
N/A | |
Completed |
NCT06141122 -
The Colonoscopy Booklet:Effect of a Recipe Resource on Quality of Colonoscopy Bowel Preparation and Patient Experience
|
N/A | |
Not yet recruiting |
NCT04534868 -
Patient Acceptance And Satisfaction of Teledermoscopy In General Practice In a Belgian Rural Area
|
N/A | |
Completed |
NCT04823390 -
Anesthetist Controlled Versus Patient-controlled Sedation: Risks and Benefits
|
Phase 1 | |
Recruiting |
NCT05884684 -
What is the Potential Impact of Reviewing Post-procedure Images With Patients Following Interventional Spine Procedures.
|
N/A | |
Recruiting |
NCT05613439 -
The Fast-track Centre for Hip and Knee Replacement Database
|
||
Recruiting |
NCT06451510 -
Knee Osteoarthritis in the Region of Norrbotten
|
||
Completed |
NCT04420000 -
Effects of Mindfulness Therapy in Patients With Acromegaly and Cushing
|
N/A | |
Withdrawn |
NCT04625842 -
Focus Group Interview Study on Patient Experiences and Satisfaction
|
N/A | |
Recruiting |
NCT04842240 -
Comparison of Patient Reported Outcome Measures Using the BREAST-Q Questionnaire in Patients Undergoing Pre Versus Sub-pectoral Implant Based Immediate Breast Reconstruction.
|