Patient Satisfaction Clinical Trial
Official title:
Comparison of Patient Satisfaction and Chewing Efficiency Between Conventional and 3D Printed Complete Dentures. A Randomized Crossover Clinical Trial
Twenty completely edentulous patients were enrolled in this study. Each patient received two types of prostheses. 1) Conventional complete dentures. 2) 3D printed dimethacrylate-based resin complete dentures. Patient satisfaction was assessed using the oral health impact profile (OHIP-EDENT-N) survey questionnaire, and masticatory performance was evaluated with the two-colored chewing gum mixing ability by evaluation of the standard deviation of hue at (T0) at the time of complete denture insertion, (T3) after 3 months of denture use and (T6) after 6 months of denture use.
For each patient, conventional maxillary and mandibular complete dentures were constructed, followed by 3D printed complete dentures construction as follows: Scanning of maxillary and mandibular complete dentures and scanning of master casts were done using 3D scanner (VDSL Home Gateway model EchoLife DG8045 China) after lightly coated with anti-glare spray (Siladent Marmoscan spray basic Ref. 250022). The resultant data in STL format were transmitted to the CAD-CAM complete denture provider using a purpose-built software program (Exocad DentalIDB 2.4 plovdiv7290[version 2.4 Enginebuld 7290]). The anatomic landmarks were identified, and the peripheral limits were marked on a virtual model in the design software, which then were served to design the definitive complete denture. The scanned STL image of the conventional complete denture which have been previously constructed was superimposed on the newly designed denture for comparison of polished surface, teeth alignment, size, and form of teeth. A digital preview was generated and sent for approval before fabrication. Printing Preparation: The denture base shade was selected, and then the cassette of the 3D printer (RASDENT 3D printer) was filled with fresh DENTCA Denture Base II dimethacrylate-based resins with photo-initiator). Then the printer door closed. Printing procedures: The denture base model STL file was uploaded into the software. The denture base was oriented vertically on the build platform. Supports were generated around the perimeter of the denture base. The desired slice thickness was selected and then the printing was started. Cleaning, Bonding teeth to the denture base, Post-curing procedures, Finishing Evaluation of patient satisfaction: The OHRQoL of the patient was assessed using an instrument called OHIP-EDENT-N10. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04079543 -
NPO and Patient Satisfaction in the Cath Lab
|
N/A | |
Enrolling by invitation |
NCT05053958 -
Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.
|
N/A | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT04774562 -
The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery
|
N/A | |
Terminated |
NCT04604340 -
Radial Versus Femoral Arterial Access for Cerebral Angiography in Adolescents
|
N/A | |
Recruiting |
NCT04539210 -
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
|
N/A | |
Completed |
NCT02924974 -
Spinal Morphine in Robotic Assisted Radical Prostatectomy
|
Phase 4 | |
Completed |
NCT01052415 -
POL and Access Intervention to Reduce HIV Stigma Among Service Providers in China
|
N/A | |
Recruiting |
NCT06044103 -
Patient-controlled Sedation During Repair of Obstetric Perineal Lacerations
|
Phase 4 | |
Not yet recruiting |
NCT05670080 -
Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair?
|
N/A | |
Completed |
NCT06114524 -
Effect of Binaural Beats on Level of Anxiety and Toleration in Patients Undergoing Upper Gastrointestinal Endoscopy Without Sedation
|
N/A | |
Completed |
NCT06141122 -
The Colonoscopy Booklet:Effect of a Recipe Resource on Quality of Colonoscopy Bowel Preparation and Patient Experience
|
N/A | |
Not yet recruiting |
NCT04534868 -
Patient Acceptance And Satisfaction of Teledermoscopy In General Practice In a Belgian Rural Area
|
N/A | |
Completed |
NCT04823390 -
Anesthetist Controlled Versus Patient-controlled Sedation: Risks and Benefits
|
Phase 1 | |
Recruiting |
NCT05884684 -
What is the Potential Impact of Reviewing Post-procedure Images With Patients Following Interventional Spine Procedures.
|
N/A | |
Recruiting |
NCT05613439 -
The Fast-track Centre for Hip and Knee Replacement Database
|
||
Recruiting |
NCT06451510 -
Knee Osteoarthritis in the Region of Norrbotten
|
||
Withdrawn |
NCT04625842 -
Focus Group Interview Study on Patient Experiences and Satisfaction
|
N/A | |
Completed |
NCT04420000 -
Effects of Mindfulness Therapy in Patients With Acromegaly and Cushing
|
N/A | |
Recruiting |
NCT04842240 -
Comparison of Patient Reported Outcome Measures Using the BREAST-Q Questionnaire in Patients Undergoing Pre Versus Sub-pectoral Implant Based Immediate Breast Reconstruction.
|