Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05565261
Other study ID # EAvukat
Secondary ID
Status Completed
Phase
First received
Last updated
Start date December 17, 2019
Est. completion date January 15, 2022

Study information

Verified date September 2023
Source Eskisehir Osmangazi University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Objectives: The purpose of this study is to evaluate bite force (BF), oral health-related quality of life (OHRQoL), and patient satisfaction in 2-implant-supported overdentures. In addition, the effects of clinical parameters such as age, gender, implant length, implant diameter, locator attachment height, attachment color, and interimplant distance were also evaluated. Material and Methods: A total of 51 patients were included in the study. BFs were measured with a force meter in complete dentures and implant-supported overdentures. OHRQoL was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS).


Description:

New complete dentures with bilateral balanced occlusion were fabricated for the patients. The patients wore the prosthesis for at least 8 weeks to allow the muscles to adapt. After adaptation to the dentures, 2 dental implants (Astra Tech Implant System, Dentsply Sirona) were placed in the interforaminal region of the mandible. A minimum of 3 months was waited for the dental implants to osseointegrate. After osseointegration, a clinical examination of the prostheses was performed. The clinical examination evaluated the accuracy of the prostheses in terms of occlusion and vertical dimension, their adaptation to the tissue, and the health of the soft tissue. If cracks or fractures were present, the prosthesis was repaired, and if a defect in tissue adaptation was detected, the prostheses were idealized by relining. The OccluSense® computerized occlusion analysis system (Dr. Jean Bausch GmbH & Co. KG, Cologne, Germany) was used to check occlusion evaluation, masticatory force distribution, and premature contact due to wear. In the case of premature contact, contacts were eliminated and the first bite force (BF) values of patients with correct occlusion were measured. The maximum BF was measured with a forcemeter (Akson, Istanbul, Turkey). The intraoral sensor of the device was placed unilaterally at the level of the 1st molar. To ensure stability, a bite block of the same thickness was placed in the contralateral dental arch. Patients were seated in a comfortable position with the Frankfurt horizontal plane parallel to the horizontal plane. Patients were asked to bite hard for 3 seconds and the measurement was repeated 3 times. To obtain a reliable value, patients rested for 1 minute after each measurement. The maximum BF was accepted as the highest value among the three bite forces. The mean value of the unilateral right and left measurements was used for data analysis. After measurement, the dentures were attached to the Locator Attachments (Zest Anchors LLC, Escondido, USA). Patients had to wait at least 8 weeks to adapt to the implant-supported overdentures. After the adaptation period, the second BF values of the patients wearing complete dentures in the maxilla and implant-supported overdentures in the mandible were measured. Oral health-related quality of life and patients satisfaction In this phase, patients were asked to complete the OHIP-14 questionnaires to assess their quality of life and VAS forms to assess patient satisfaction. To assess the impact of clinical parameters, age, gender, implant lengths, implant diameters, locator attachment height, attachment color, and interimplant distance were also recorded. OHRQoL was assessed using the Turkish version of the Oral Health Impact Profile (OHIP-14). Patients were asked to indicate how often the corresponding OHIP parameter occurred in the past month. OHIP-14 contains 14 questions related to 7 different main topics. The 7 main themes are functional limitations, physical pain, psychological discomfort, physical disability, psychological disability, social disability, and handicap. Patients answered the questions as 0 = Never, 1 = Rarely, 2 = Occasionally, 3 = Quite often, and 4 = Frequently. Scoring was based on 7 main categories and 8 data as the sum of all these categories. The total score of the OHIP-14 is at least 0 and the highest score is 56. A low score at the end of the test indicates a positive impact on OHRQoL, while a high score indicates a negative impact. Patient satisfaction was measured with the questionnaire VAS. The questions in the questionnaires evaluated the comfort of the prosthesis, convenience in chewing, aesthetics, speech, stability, and ease of cleaning. Patients answered the questions with 5=Totally satisfied, 4=Satisfied, 3=Adequate, 2=Not satisfied, 1=Not at all satisfied. Higher scores indicate higher patient satisfaction.


Recruitment information / eligibility

Status Completed
Enrollment 51
Est. completion date January 15, 2022
Est. primary completion date January 15, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 47 Years to 80 Years
Eligibility Inclusion criteria: - Patients without pathology in intraoral tissues - Patients who have not experienced implant loss until the prosthesis stage - Patients without any systemic disease that would endanger the prognosis of the implant - Patients with good bilateral balanced occlusion - Patients who could understand and answer the questions in the questionnaire were included in the study. Exclusion Criteria: - Patients with parafunctional habits - Patients with masticatory muscles or temporomandibular joint complaints - Patients using drugs that affect muscle activity - Patients who did not come to the control session on time were excluded from the study.

Study Design


Intervention

Device:
complete denture
Bite force was measured with a bite force measuring device. Quality of life and patient satisfaction were evaluated with questionnaires.

Locations

Country Name City State
Turkey Esra Nur Avukat Odunpazari Eskisehir

Sponsors (1)

Lead Sponsor Collaborator
Eskisehir Osmangazi University

Country where clinical trial is conducted

Turkey, 

References & Publications (6)

Enkling N, Saftig M, Worni A, Mericske-Stern R, Schimmel M. Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year. Clin Oral Implants Res. 2017 Apr;28(4) — View Citation

Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGi — View Citation

Muller F, Duvernay E, Loup A, Vazquez L, Herrmann FR, Schimmel M. Implant-supported mandibular overdentures in very old adults: a randomized controlled trial. J Dent Res. 2013 Dec;92(12 Suppl):154S-60S. doi: 10.1177/0022034513509630. Epub 2013 Oct 24. — View Citation

Mumcu E, Bilhan H, Geckili O. The effect of attachment type and implant number on satisfaction and quality of life of mandibular implant-retained overdenture wearers. Gerodontology. 2012 Jun;29(2):e618-23. doi: 10.1111/j.1741-2358.2011.00531.x. Epub 2011 — View Citation

Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the f — View Citation

Wang Y, Baumer D, Ozga AK, Korner G, Baumer A. Patient satisfaction and oral health-related quality of life 10 years after implant placement. BMC Oral Health. 2021 Jan 14;21(1):30. doi: 10.1186/s12903-020-01381-3. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Bite force Bite force in Newton December 2019-January 2022
Primary Interimplant distance Interimplant distance in millimeters December 2019-January 2022
Primary The height of the locator attachment The height of the locator attachment is in millimeters. December 2019-January 2022
Primary Quality of Life Quality of Life was assessed using the Oral Health Impact Profile(OHIP-14) (0-4 units, 0 for never to 4 for always). December 2019-January 2022
Primary Patient satisfaction Patient satisfaction was assessed using the VAS(visual analogue scale, 1-5 units, 1 not satisfied to totally satisfied). December 2019-January 2022
Primary Dental implant length Dental implant length in millimeters December 2019-January 2022
Primary Dental implant diameter Dental implant diameter in millimeters December 2019-January 2022
See also
  Status Clinical Trial Phase
Not yet recruiting NCT04079543 - NPO and Patient Satisfaction in the Cath Lab N/A
Enrolling by invitation NCT05053958 - Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone. N/A
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT04774562 - The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery N/A
Terminated NCT04604340 - Radial Versus Femoral Arterial Access for Cerebral Angiography in Adolescents N/A
Recruiting NCT04539210 - Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment. N/A
Completed NCT02924974 - Spinal Morphine in Robotic Assisted Radical Prostatectomy Phase 4
Completed NCT01052415 - POL and Access Intervention to Reduce HIV Stigma Among Service Providers in China N/A
Recruiting NCT06044103 - Patient-controlled Sedation During Repair of Obstetric Perineal Lacerations Phase 4
Not yet recruiting NCT05670080 - Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair? N/A
Completed NCT06141122 - The Colonoscopy Booklet:Effect of a Recipe Resource on Quality of Colonoscopy Bowel Preparation and Patient Experience N/A
Completed NCT06114524 - Effect of Binaural Beats on Level of Anxiety and Toleration in Patients Undergoing Upper Gastrointestinal Endoscopy Without Sedation N/A
Not yet recruiting NCT04534868 - Patient Acceptance And Satisfaction of Teledermoscopy In General Practice In a Belgian Rural Area N/A
Completed NCT04823390 - Anesthetist Controlled Versus Patient-controlled Sedation: Risks and Benefits Phase 1
Recruiting NCT05884684 - What is the Potential Impact of Reviewing Post-procedure Images With Patients Following Interventional Spine Procedures. N/A
Recruiting NCT05613439 - The Fast-track Centre for Hip and Knee Replacement Database
Recruiting NCT06451510 - Knee Osteoarthritis in the Region of Norrbotten
Completed NCT04420000 - Effects of Mindfulness Therapy in Patients With Acromegaly and Cushing N/A
Withdrawn NCT04625842 - Focus Group Interview Study on Patient Experiences and Satisfaction N/A
Recruiting NCT04842240 - Comparison of Patient Reported Outcome Measures Using the BREAST-Q Questionnaire in Patients Undergoing Pre Versus Sub-pectoral Implant Based Immediate Breast Reconstruction.