Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT04539210
Other study ID # PRO6-2-1
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date September 2020
Est. completion date February 2022

Study information

Verified date April 2020
Source Cairo University
Contact faculty of dentistry,cairo university
Phone 02 35676105
Email dentmail@dentistry.cu.edu.eg
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

In this study the investigators are going to compare the effect of electric welded metal frame work and cast frame work on patient satisfaction and maintenance of the final prosthesis.


Description:

In this study twelve completely edentulous patients will be enrolled and In each patient six implants will be inserted in the maxillary arch at crestal bone level in predefined positions (positions 15, 13, 11, 21, 23, 25) with the help of a surgical template following a submerged healing protocol and checked for primary stability clinically. After a 4-month osseointegration period, second-stage surgery will be performed and healing abutments will be placed. After the second-stage surgery, prosthetic procedures will be initiated.

then for one side (the intervention side) the metal framework will be constructed as follow: A preexisting or prepared flat surface area of the welding abutment of implant at central incisor position at one side (right or left) will serve as the welding point. A titanium bar will be shaped following the curvature of the implants positioned. At this point, temporary titanium implant abutments will be welded with the titanium bar in the oral cavity, using the Syncrystallization Unit .The welding process is electrical and protected by an argon gas supply (Syncrystallization). The equipment allows the welding of metallic elements directly in the mouth. Current flowing through the contact points, being in contact with the parts to weld, warms up to the point of fusion, achieving a solid, welded junction. Then will be placed between the two electrodes of a welding clamp. The energy contained in a previously unloaded battery of capacitors is transferred to the electrodes of the welding cycle is subdivided in three stages: Pre-gas, welding, and post-gas phase. While the pre-gas phase allows an oxygen-free welding point prior to the actual fusion, the post-gas phase ensures the absence of oxygen and subsequent oxidation during cooling. Finally, the prosthetic framework, created by welding the titanium bar to the implant abutments, will be removed and opaque will be applied in order to avoid metal shining through the acrylic resin.

for the other side :

At the day of second stage surgery restoration will be fabricated as follow:

For the cast metal framework group, CCM abutments (Titanium base abutments with a plastic cast able sleeve) will be fastened over the analogues of the placed implants, on a verified analogue model.

For the preparation of the verified model, open tray (pick-up) impression copings will be fastened to the placed implants, and an un splinted impression will be made using addition silicone impression material in a single step manner, using putty and light consistency addition silicone.

A stone model will be obtained after fastening of the implant analogues, fabrication of a gingival mask and pouring the impression using extra-hard dental stone. Over the obtained stone model, splinting of the open tray impression copings will be performed using duralay resin to obtain a jig that will be further separated and resplinted intra orally, over which a splinted pick-up impression will be remade. The new impression will be poured into extra-hard stone after fabricating a gingival mask.

On the verified master analogue model, occlusion blocks will be constructed for adjustment of vertical dimension and bite registration. Afterwards, CCM abutments will be fastened, followed by waxing, spruing and casting. The resultant framework will be inserted inside the patient's mouth on the following implants; right or left implants installed; central, canine, and second premolar to insure passivity of fit. In case of framework misfit, separation will be performed using a disc, followed by intraoral splinting using duralay resin and soldering. After framework soldering, another try-in will be done to insure framework fit, then the final pick-up of the framework into the denture will be performed. Then the final prosthesis will be sectioned at the midline resulting two separate super structures.

then Patient satisfaction will be assessed using Boerrigter's method questionnaire after 3,6 and 12 months.

During the 12 months follow-up period as follow(within 2weaks of delivery,6months after delivery and 12 months after delivery) , number of prosthodontic complications for the laser welded and cast metal framework supported over dentures will be registered and calculated according to the following events: screw loosening of the abutment, screw loosening of the prosthesis, fracture of the screw of the abutment, fracture of the screw of the prosthesis, abutment fracture, framework fracture, fracture of acrylic resin denture, loss of cover of access hole, prosthetic teeth fracture and remake of the prosthesis, occlusal discrepancies ,maxillary and mandibular denture relining if needed ,pain.


Recruitment information / eligibility

Status Recruiting
Enrollment 12
Est. completion date February 2022
Est. primary completion date January 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 45 Years to 65 Years
Eligibility Inclusion Criteria:

- Age range from 45 to 65 years old.

- Absence of any medical disorder that could complicate the surgical phase or affect osseointegration .

- The patients must be completely edentulous.

- The patient must have enough bone height for implants, minimum length of bone 10mm and a minimum diameter of bone 5 mm.

- Patients with good oral hygiene.

- Complete denture wearer.

- Adequate inter arch space for screw retained prosthesis.

- Absence of any intra-oral pathological condition.

Exclusion Criteria:

- Patients with recent extraction(less than three months).

- Patients with inflamed ridge or candida infection.

- Patients with flappy ridge.

- Para functional habits.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Electric Welded Metal Framework
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework

Locations

Country Name City State
Egypt Faculty of Dentistry Cairo

Sponsors (1)

Lead Sponsor Collaborator
Cairo University

Country where clinical trial is conducted

Egypt, 

Outcome

Type Measure Description Time frame Safety issue
Primary patient satisfaction satisfaction assessed by Boerrigter's method questionnaire.in this questionnaire, there are three aspects to consider:(1) problems with the denture itself;(2) masticating ability; and (3) overall denture performance. different answers to each question are assigned scores and the total score can be calculated for further evaluation and analysis. 12 months
Secondary Maintenance of the final prosthesis During the 12 months follow-up period as follow(within 2weaks of delivery,6months after delivery and 12 months after delivery) , number of prosthodontic complications for the laser welded and cast metal framework supported over dentures will be registered and calculated according to the following events: screw loosening of the abutment, screw loosening of the prosthesis, fracture of the screw of the abutment, fracture of the screw of the prosthesis, abutment fracture, framework fracture, fracture of acrylic resin denture, loss of cover of access hole, prosthetic teeth fracture and remake of the prosthesis, occlusal discrepancies ,maxillary and mandibular denture relining if needed ,pain. 12 months
See also
  Status Clinical Trial Phase
Not yet recruiting NCT04079543 - NPO and Patient Satisfaction in the Cath Lab N/A
Enrolling by invitation NCT05053958 - Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone. N/A
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT04774562 - The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery N/A
Terminated NCT04604340 - Radial Versus Femoral Arterial Access for Cerebral Angiography in Adolescents N/A
Completed NCT02924974 - Spinal Morphine in Robotic Assisted Radical Prostatectomy Phase 4
Completed NCT01052415 - POL and Access Intervention to Reduce HIV Stigma Among Service Providers in China N/A
Recruiting NCT06044103 - Patient-controlled Sedation During Repair of Obstetric Perineal Lacerations Phase 4
Not yet recruiting NCT05670080 - Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair? N/A
Completed NCT06114524 - Effect of Binaural Beats on Level of Anxiety and Toleration in Patients Undergoing Upper Gastrointestinal Endoscopy Without Sedation N/A
Completed NCT06141122 - The Colonoscopy Booklet:Effect of a Recipe Resource on Quality of Colonoscopy Bowel Preparation and Patient Experience N/A
Not yet recruiting NCT04534868 - Patient Acceptance And Satisfaction of Teledermoscopy In General Practice In a Belgian Rural Area N/A
Completed NCT04823390 - Anesthetist Controlled Versus Patient-controlled Sedation: Risks and Benefits Phase 1
Recruiting NCT05884684 - What is the Potential Impact of Reviewing Post-procedure Images With Patients Following Interventional Spine Procedures. N/A
Recruiting NCT05613439 - The Fast-track Centre for Hip and Knee Replacement Database
Recruiting NCT04625842 - Focus Group Interview Study on Patient Experiences and Satisfaction N/A
Completed NCT04420000 - Effects of Mindfulness Therapy in Patients With Acromegaly and Cushing N/A
Recruiting NCT04842240 - Comparison of Patient Reported Outcome Measures Using the BREAST-Q Questionnaire in Patients Undergoing Pre Versus Sub-pectoral Implant Based Immediate Breast Reconstruction.
Completed NCT04048538 - Preoperative Patient Education Via Animated Videos to Improve Patient Satisfaction and Reduce Complications in Head and Neck Surgery N/A
Completed NCT02742740 - Study Buddy (an ECA Oncology Trial Advisor) for Cancer Trials N/A