Particle Therapy Clinical Trial
— MIRANDAOfficial title:
Monitoring of Patients Treated With Particle Therapy Using Positron-Emission-Tomography (PET): The MIRANDA Study.
NCT number | NCT01528670 |
Other study ID # | MIRANDA |
Secondary ID | |
Status | Withdrawn |
Phase | |
First received | |
Last updated | |
Start date | May 2019 |
Est. completion date | May 2022 |
Verified date | May 2018 |
Source | University Hospital Heidelberg |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
The purpose of this clinical study is to investigate the clinical feasibility and
effectiveness of off-line Positron-Emission-Tomography (PET) quality assurance for promoting
the accuracy of proton and carbon ion beam therapy. One main clinical advantage of ion
therapy over conventional radiation therapy is the excellent conformation of the delivered
dose to the tumour volume while well sparing the surrounding healthy tissue. However,
clinical exploitation of this potential to the maximum extent requires in-vivo validation of
the actual treatment delivery and, in particular, of the ion beam range within the patient.
Since the primary ions are completely stopped in the target volume as opposed to photon
radiation, no conventional quality assurance techniques like transmission electronic portal
imaging can be applied to monitor ion beam therapy. Hence, ion treatment planning currently
relies on models and experimental data accurately validated in tissue-equivalent targets, but
no direct verification of the actual treatment delivery and of the ion beam range within the
patient is possible in standard clinical practice.
At present, PET offers the unique possibility to monitor the precision of ion irradiation
in-vivo and non-invasively. The method is based on the detection of the b+-activity which is
formed as a by-product of the irradiation, i.e. without administration of radio-tracers to
the patient. A positive clinical impact of in-beam (i.e. during the irradiation) PET
monitoring has been demonstrated for carbon ion therapy in the pilot project at GSI
Darmstadt, Germany, and promising clinical data of post-radiation PET/CT imaging have been
recently reported for passive proton beam delivery in USA and Japan. Therefore, a pilot
clinical study is hereby proposed at the Heidelberg Ion Therapy Center in order to 1) assess
the applicability of post-radiation PET imaging to scanned ion beam delivery, 2) identify the
patient population which may benefit from it and 3) extract population-based information on
the reliability of the beam range in different tumour locations for all the ion species
clinically available at HIT.
The investigated patients are expected to benefit from this study, since in case of detected
deviations between planned and actual treatment delivery a proper correction could be applied
in the next irradiation fraction, assuring an overall better treatment than without any
monitoring. Moreover, site-specific patient-population information on the ion range precision
at HIT might enable improvement of the CT-range calibration curve as well as safe reduction
of the treatment margins to promote enhanced treatment plan conformality for full clinical
exploitation of the promises of ion beam therapy.
Status | Withdrawn |
Enrollment | 0 |
Est. completion date | May 2022 |
Est. primary completion date | May 2022 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria - The patient is treated at the Heidelberger Ionenstrahl Therapiezentrum (HIT) with protons or carbon ions. - During the radiotherapeutic treatment patient positioning is verified using validated radiological imaging such as cone beam CT, X-ray or conventional CT (Reference-Imaging as described above). - The patient is at least 18 years of age and is able to give informed consent. - The patient has been informed about the aims and the content of the study. Exclusion Criteria - No informed consent to take part in the study. - Medical reasons that impair the patients from being in the supine position for the data acquisition time, e.g. pain. - Non-compliance of the patient. |
Country | Name | City | State |
---|---|---|---|
Germany | Department of Radiation Oncology | Heidelberg |
Lead Sponsor | Collaborator |
---|---|
University Hospital Heidelberg |
Germany,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | TBA | TBA | TBA |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03662373 -