Clinical Trials Logo

Clinical Trial Summary

The aim of the present prospective randomized controlled study is to compare the accuracy of implant placement performed either with a surgical motor or a torque wrench as part of a half-guided surgical protocol after maxillary sinus floor augmentation.


Clinical Trial Description

Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the maxilla. Forty patients were randomly divided in two study groups; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. After the healing period, accuracy comparison method between planned and actual implant positions was performed based on digital intraoral scan. Coronal, apical and angular deviation parameters, insertion time and maximum insertion torque was evaluated. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04854239
Study type Interventional
Source Semmelweis University
Contact
Status Completed
Phase Phase 4
Start date January 1, 2017
Completion date January 31, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04618055 - Clinical Evaluation of NiTiDent Tuah Porous NiTi Dental Implants N/A
Recruiting NCT05538715 - Reconstruction of Localized Alveolar Ridge Defects Phase 4
Active, not recruiting NCT04378140 - Retention and Durability of the Anterior Zirconia Wing Bridge
Active, not recruiting NCT04929743 - Randomized Clinical Trial to Evaluate the Predictability of 5.5 mm Dental Implants N/A
Active, not recruiting NCT04927819 - Extra-short vs. Non-extra-short Dental Implants Splinted on the Same Prosthesis
Active, not recruiting NCT04695899 - Zirconia Implants for Replacement of a Single Tooth
Completed NCT04029025 - Complete Digital Workflows for the Treatment With Multiple-unit Implant-supported Fixed Dental Prostheses (iFDP) N/A
Recruiting NCT06106243 - Evaluation of Digital 3D Printed Temporary Removable Partial Denture. N/A
Completed NCT05670340 - Effect of Bone-related and Soft-tissue-related Variables on the Marginal Bone Loss of Platform-matched and Platform Switched Dental Implants N/A
Recruiting NCT05583123 - One-piece and Two-piece Zirconia Abutments in Single Implant Crowns in Esthetic Region N/A
Completed NCT05526547 - Implant-supported Zirconia Partial Dentures With Cantilever
Recruiting NCT04662749 - Influence of Intruding Angle on Non-graft Osteotome Sinus Elevation
Not yet recruiting NCT06056388 - Effect of Fixture Thread Depth on Accuracy of Immediate Implant Placement Using Dynamic Navigation N/A
Recruiting NCT06273449 - A Smart Digital Workflow Towards High Precision and Through-Put Production for Removable Partial Dentures N/A
Not yet recruiting NCT04895969 - Prevalence of Partial Edentulism Among Patients of Faculty of Dentistry Cairo University