Pancreatic Solid Lesions Clinical Trial
Official title:
National Taiwan University Hospital
In the previous studies, EUS-guided fine needle aspiration (FNA) with fanning technique in solid pancreatic lesions (SPLs) with avascular areas had a negative impact on diagnostic accuracy of FNA. Because of the retrospective basis of previous studies, a prospective study is warranted to answer whether contrast-enhanced harmonic(CEH) EUS-guided FNA/B is superior to conventional EUS-guided FNA/B with fanning technique in SPLs. The main objective of this randomized trial therefore was to determine whether CEH-EUS-guided sampling to avoid non-enhanced areas within a mass lesion result in more rapid diagnosis requiring fewer FNB passes than the conventional EUS-guided FNB with fanning needle throughout the mass is targeted.
A prospective randomized controlled study was undertaken of patients with solid pancreatic mass lesions who were referred for EUS. Total 120 patients were randomized with 1:1 ratio into undergo CEH-EUS-guided FNB or conventional EUS-guided FNB with fanning technique. At the time of the procedure, the endoscopy nurse opened an envelope containing computer-generated randomization assignments for the study patients. All procedures were performed by a linear array echoendoscope (Olympus UCT260; Olympus, Tokyo, Japan). Procedures were performed under conscious sedation with patients in the left lateral decubitus position. In CEH-EUS-guided FNB group, needle puncture directly to the enhancing area 15-20 times without passing to the non-enhancing area was performed. In conventional-EUS-guided FNB with fanning technique group, the needle was positioned at four different areas within the mass and then moved back and forth four times in each area to procure tissue (4 × 4). After each pass, the needle is removed and the stylet will be introduced into the needle to extrude any aspirated material on a glass slide for inspection of the presence of a macroscopic visible core (MVC). The total length of the MVC will be measured before placement into a formalin bottle. EUS-FNB is completed if the obtained MVC is longer than 4mm and deemed adequate by endoscopist. If the obtained MVC is < 4mm, the procedure is repeated until a MVC of ≥ 4mm is obtained and deemed adequate by endoscopist. A maximum of 7 passes is allowed. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03849209 -
Different Suction Techniques For Endoscopic Ultrasound-Guided Fine-Needle Biopsy In Pancreatic Solid Lesions
|
N/A | |
Recruiting |
NCT05018663 -
Artificial Intelligence (AI) Cytopathology Trial
|
||
Completed |
NCT03821974 -
The Comparison of Wet Suction and Dry Suction Technique in EUS-FNA for the Outcomes in Pancreatic Solid Lesions
|
N/A | |
Completed |
NCT01936467 -
Comparison of Two Needle Aspiration Techniques for Endoscopic Ultrasound-guided Fine Needle Aspiration (EUS-FNA) in Solid Pancreatic Lesions
|
Phase 3 | |
Completed |
NCT04924725 -
Prospective Comparison of Diagnostic Accuracy Between Contrast-enhanced Harmonic and Conventional EUS-guided Fine-needle Biopsy in Solid Pancreatic Lesions
|
N/A |