Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT03049215
Other study ID # 170247
Secondary ID
Status Terminated
Phase N/A
First received
Last updated
Start date November 6, 2017
Est. completion date December 31, 2019

Study information

Verified date August 2021
Source Vanderbilt University Medical Center
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The study hypothesis is that placement of LAMS plus an overlapping double pigtail stent for endoscopic transmural drainage of PFCs with solid debris will result in improved drainage and require fewer endoscopic interventions compared to placement of LAMS alone.


Description:

The study hypothesis is that placement of LAMS plus an overlapping double pigtail stent for endoscopic transmural drainage of PFCs with solid debris will result in improved drainage and require fewer endoscopic interventions compared to placement of LAMS alone. Adult patients with symptomatic pancreatic fluid collections who are scheduled to undergo EUS-guided drainage of PFCs with LAMS placement will be eligible for study participation. The initial portion of this procedure consists of diagnostic EUS for imaging and assessment of the PFC. This EUS examination is able to distinguish the relative liquid and solid components of PFCs, detail which may not be evident by CT imaging. Adult patients with PFCs consisting of >30% solid component as assessed at the time of EUS will be eligible for randomization. This threshold was selected as the enrollment criteria in order to select patients with a significant solid necrotic component to the lesion, as prior study of patients undergoing LAMS placement for drainage of PFCs have used >70% fluid content as the definition for a PFC with predominantly liquid contents. Allocation to study arm will be determined by the contents of sealed envelope. Subjects randomized to LAMS alone will undergo EUS-guided transmural placement of an Axios stent with a 15 mm luminal diameter. The choice of transgastric or transduodenal LAMS placement will be at the discretion of the endoscopist and contingent upon PFC location and window relative to the EUS transducer. Subjects randomized to LAMS plus double pigtail stent will undergo EUS-guided transmural placement of a single Axios stent with a 15 mm luminal diameter; following this, wire access across the stent lumen will be achieved using a 0.035 inch hydrophilic guidewire, and a double pigtail plastic biliary stent (6 French, 7 French, or 10 French at the discretion of the endoscopist) will be deployed over the wire. The use of fluoroscopy for stent deployment will be at the discretion of the endoscopist. The primary end point: Greater than 50% decrease in size of PFC (in mm), compared to pre-intervention size (in mm), on cross-sectional computed tomography (CT) imaging at 30 days following stent placement. This was selected as the primary outcome in order to maintain consistency with the primary outcomes of a prior multicenter study of LAMS placement for PFCs.


Recruitment information / eligibility

Status Terminated
Enrollment 2
Est. completion date December 31, 2019
Est. primary completion date December 31, 2019
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria: - Male and Female patients between the ages of 18 and 80 - Must be presenting with symptomatic pancreatic fluid collections - Scheduled to undergo endoscopic ultrasound (EUS)-guided drainage of PFCs with LAMS placement at Vanderbilt Medical Center as part of routine care - Willing and able to give informed consent Exclusion Criteria: - Unwilling/unable to give informed consent - Patients with PFCs consisting of < 30% solid component as assessed at the time of EUS

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Lumen Apposing Metal Stent (LAMS)
The AXIOS Stent and Electrocautery-Enhanced Delivery System is an endoscopic device designed to enable the ultrasound trained interventional endoscopist to deliver a transenteric stent between the gastrointestinal tract and a pancreatic pseudocyst.
LAMS plus double pigtail stent
The AXIOS Stent and Electrocautery-Enhanced Delivery System is an endoscopic device designed to enable the ultrasound trained interventional endoscopist to deliver a transenteric stent between the gastrointestinal tract and a pancreatic pseudocyst. The double pigtail stent is a routinely used plastic biliary stent.

Locations

Country Name City State
United States Vanderbilt University Medical Center Nashville Tennessee

Sponsors (1)

Lead Sponsor Collaborator
Vanderbilt University Medical Center

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Decrease in Pancreatic Fluid Collection (PFC) Greater than 50% decrease in size of PFC (in mm) compared to pre-intervention size (in mm) as measured on cross-sectional computed tomography (CT) imaging 30 days following placement of stent
Secondary Clinical Success Rate for Draining of Pancreatic Fluid Collection (PFC) Clinical success for drainage of PFC, defined as complete resolution of PFC on follow-up computed tomography (CT) imaging and stent removal within 3 months 3 months
Secondary Number of Endoscopic Interventions Required for Resolution of PFC Prior to Stent Removal Number of endoscopic interventions required for resolution of Pancreatic Fluid Collection (PFC) prior to stent removal 3 months
Secondary Incidence of Hospital Readmissions Following Initial Endoscopic Intervention and Prior to Resolution of Pancreatic Fluid Collection Stent Removal Incidence of hospital readmissions following initial endoscopic intervention and prior to resolution of Pancreatic Fluid Collection (PFC) stent removal 3 months
Secondary Incidence of Surgical or Percutaneous Radiologic Intervention for PFC Following Initial Endoscopy Intervention Incidence of surgical or percutaneous radiologic intervention for Pancreatic Fluid Collection (PFC) following initial endoscopy intervention 3 months
Secondary Incidence of Early (<30 Days) Endoscopic Reintervention Incidence of early (<30 days) endoscopic reintervention following initial endoscopic intervention 30 days
See also
  Status Clinical Trial Phase
Not yet recruiting NCT03027895 - Endoscopic Ultrasound-guided Drainage of Walled Off Necrosis (WON) N/A
Terminated NCT00541593 - Natural Orifice Translumenal Endoscopic Surgery (NOTES) Cystgastrostomy for the Treatment of Pancreatic Pseudocysts N/A
Completed NCT03002051 - EUS-guided Transenteric Drainage With a Novel Lumen-apposing Metal Stent N/A
Not yet recruiting NCT06133023 - WONDER-02 Trial: Plastic Stent vs. Lumen-apposing Metal Stent for Pancreatic Pseudocysts N/A
Completed NCT02041793 - Laparoscopic Cystogastrostomy Versus Endoscopic Cystogastrostomy N/A
Recruiting NCT06179459 - Registry of Patients Undergoing Endoscopic Management of Pancreatic Fluid Collections
Completed NCT02730663 - A Study to Evaluate the Effectiveness and Safety of EUS-guided Transluminal Drainage With 'Niti-S SPAXUS Stent' N/A
Recruiting NCT05716594 - Clinical Evaluation of Enteral-extended Anti-reflux Stents for Pancreatic Pseudocyst Phase 2
Completed NCT00222898 - Cancer Detection in Pancreatic Cysts N/A
Recruiting NCT05451901 - Immediate Necrosectomy vs. Step-up Approach for Walled-off Necrosis N/A
Recruiting NCT01585662 - Prospective Random Comparing Study on EUS-guided Pseudocyst Drainage by Naso-pancreatic Tube and Stents Phase 4
Recruiting NCT02845258 - Treatment of Pancreatic Pseudocysts by Endoscopic Ultrasound-guided Drainage
Completed NCT03797209 - Hot AXIOS System Japan Post Market Survey
Not yet recruiting NCT06134024 - The Role of Double Pigtail Plastic Stents During Endoscopic Transmural Drainage of Pancreatic Fluid Collections. N/A
Completed NCT03147768 - Laser Tissue Welding - Distal Pancreatectomy Sealing Study Phase 1
Not yet recruiting NCT03022110 - Endoscopic Ultrasound-guided Drainage of Pancreatic Pseudocysts N/A
Active, not recruiting NCT03884179 - Diagnosis of PCL With EUS-FNA and Cross-sectional Imaging - A Report of Accuracy