Rationale: Until now there are no prospective studies comparing the 22 gauge and 25 gauge side-fenestrated and fork-tip needles. In the present study we will compare the two types of needles in terms of histological yield for the evaluation of solid pancreatic lesions in the absence of rapid on-site evaluation (ROSE). Moreover diagnostic accuracy and the number of passes necessary to achieve the maximum diagnostic and histological yield, and safety will be investigated. Objectives: To evaluate and compare the histologic retrieval rate of two different EUS-FNB needles of the same caliber (22 or 25 gauge). The passes will be 3 for each patient. Study design: Randomized monocentric trial. Study population: Patients ≥18 years old, referred for EUS-guided tissue sampling of a solid pancreatic mass. Intervention: EUS-guided tissue acquisition by mean EUS-FNB, using one of the following FNB needles: side-fenestrated 22 gauge, side-fenestrated 25 gauge, fork-tip 22 gauge or fork-tip 25 gauge. Main study parameters/endpoints: The main endpoint is the histologic yield (defined as the percentage of a tissue core of at least 550 micron at the greatest axis), obtained at each of the 3 needle passes. Secondary endpoints include: i) safety; ii) concordance between macroscopic on-site evaluation (MOSE) and histopathological evaluation ; iii) Accuracy using 1, 2 or 3 passes.


Clinical Trial Description

Endoscopic ultrasound (EUS) has become an essential procedure in the last decade for evaluation of focal pancreatic lesions and for tissue acquisition for diagnostic purposes. In these patients the endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and, more recently, the introduction of EUS fine needle biopsy (EUS-FNB), is a safe instrument, with high sensitivity (75-98 %) and specificity (71-100%). The obtaining of bioptic tissue samples reduces the need for rapid on site-evaluation (ROSE) and allows an easier interpretation of the diagnosis even by non-expert pathologist. It also makes possible to perform ancillary investigations such as immunohistochemical, often useful for the differential diagnosis. Two different EUS-FNB needles are available: the side-fenestrated reverse bevel and the fork-tip forward-acquiring". Both are available in 25, 22 and 19 gauge. The 22 gauge is the most commonly used since it combines the ease of use of small-sized caliber with the advantages of larger sized needles. The 25 gauge is universally recognized as the most manageable and flexible needle and is preferred when the lesion is small (<20mm) or is in "difficult" conditions (lesion localized to the uncinate process or to distal tail, lesion distant from the transducer > 15mm, need to cross > 1cm of healthy pancreas, angled position of the instrument). There are no prospective studies comparing the 22 and 25 gauge side-fenestrated and fork-tip needles. We therefore propose a prospective randomized study, to compare the two types of needles in terms of histologic and diagnostic yield, number of passes necessary to reach it in solid pancreatic lesions, in the absence of ROSE. This is a randomized single center trial with two parallel arms in a (1:1) ratio. Consecutive patients with solid pancreatic masses and an indication to perform EUS-guided tissue acquisition will be evaluated and, if eligible, will be enrolled into the study. Randomization will take place after the lesion will have been visualized with EUS and the patient will be found suitable for inclusion. The choice of needle gauge (22 or 25 gauge) will be at the discretion of the endosonographer in relation to the difficulty/risk of the procedure; therefore, two randomization lists will be drawn up, (one for the 22 gauge and one for the 25 gauge). The choice of the needle gauge will be done before randomization so that the choice of the needle does not create bias in the results. The pathologist will be blinded to the needle caliber and type. The sample size has been calculated for the primary outcome (histologic retrieval rate) using a group sequential design to define a proper interim analysis after at least 50% enrolment. The histologic yield of the two needle types can be summarized as follows: 22 gauge: 77% and 92% for the side-fenestrated and the fork-tip, respectively. 25 gauge: 60.5% and 85% for the side-fenestrated and the fork-tip, respectively. With a type I error α of 5% and a power 1 - β of 80%, the total required sample size amounts to 330 patients (210 patients for 22G group and 120 patients for 25G group). Considering that 18% of patients must be added to counteract the estimated and lost drop-out rate at follow-up, overall 362 patients will be needed (196 patients for the 22G group and 112 patients for the 25G group). Based on sample size calculation the two lists will consist in 24 blocks of 8 patients and 1 block of 4 patients for the 22G group and 14 blocks of 8 patients for the 25G group. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03622229
Study type Interventional
Source Azienda Ospedaliera Universitaria Integrata Verona
Contact
Status Completed
Phase N/A
Start date November 1, 2018
Completion date August 30, 2020

See also
  Status Clinical Trial Phase
Completed NCT01354795 - Prospective Study Comparing Methods of Obtainment of Specimen After EUS-FNA in Patients With Peri-pancreatic Mass N/A
Completed NCT00958841 - Study of Pasireotide in Patients With Rare Tumors of Neuroendocrine Origin Phase 2
Terminated NCT00249301 - A Study of MLN8054 in Patients With Advanced Solid Tumors Phase 1
Recruiting NCT06122896 - Prospective Screening for Pancreatic Ductal Adenocarcinoma in High-Risk Individuals Early Phase 1
Terminated NCT02602067 - 131Iodine-Tenatumomab Treatment in Tenascin-C Positive Cancer Patients Phase 1
Completed NCT02791503 - CROSSFIRE Trial: Comparing the Efficacy of Irreversible Electroporation With Radiotherapy N/A
Recruiting NCT05786716 - DETERMINE Trial Treatment Arm 04: Trastuzumab in Combination With Pertuzumab in Adult, Teenage/Young Adult and Paediatric Patients With Cancers With HER2 Amplification or Activating Mutations Phase 2/Phase 3
Completed NCT03322592 - EUS-FNB With ROSE Vs. EUS-FNB Without ROSE N/A
Completed NCT05745415 - Cancer Stem Cell Specific Aptamer's Ability to Detect Blood Circulating Cancer Stem Cells and Its Role as a Predictor of Prognosis in Pancreatic Cancer
Recruiting NCT05083247 - Preoperative mFOLFIRINOX (or Gem-Nab-P) +/- Isotoxic High-dose SBRT for Borderline Resectable Pancreatic Adenocarcinoma Phase 2
Completed NCT00436423 - A Phase Ⅱ Study of Gemcitabine Combination With TS-1 in Patient With Advanced or Recurred Pancreatic Cancer Phase 2
Completed NCT02900950 - Multicolour Versus Monocolour Specimens Inking After Pancreaticoduodenectomy for Periampullary Cancer N/A
Completed NCT00711191 - A Study On An Immunostimulant Antibody In Combination With Chemotherapy For Advanced Cancer Of The Pancreas Phase 1
Completed NCT00222898 - Cancer Detection in Pancreatic Cysts N/A
Completed NCT00034281 - Safety and Tolerability Study of TAK-165 in Subjects With Tumors Expressing HER2 Phase 1
Completed NCT00005926 - Gemcitabine, Herceptin and Radiation to Treat Cancer of the Pancreas Phase 2
Recruiting NCT04164017 - Impact of Suction in the EUS-guided Fine Needle Biopsy of Solid Pancreatic Lesions N/A
Recruiting NCT05687123 - Testing the Addition of Sunitinib Malate to Lutetium Lu 177 Dotatate (Lutathera) in Pancreatic Neuroendocrine Tumors Phase 1
Completed NCT03616431 - Pancreatic Cancer Dietary Assessment Study
Recruiting NCT02436564 - In Vitro Models of Liver and Pancreatic Cancer N/A