Pacemaker Clinical Trial
Official title:
A Single Center, Prospective, Pilot Study Examining the Evaluation of Exercise Capacity in Chronically RV Paced Children and Young Adults
Verified date | May 2012 |
Source | Emory University |
Contact | n/a |
Is FDA regulated | No |
Health authority | United States: Institutional Review Board |
Study type | Observational |
The purpose of this study is to evaluate the exercise capacity of patients with complete heart block who are chronically being paced from the right ventricle. Also, we hope to correlate the level of uncoordinated contraction with the patients exercise capacity. We will enroll patients with complete heart block as diagnosed by standard electrocardiographic means and now have a permanent pacemaker. All patients we approach for this study will receive an echocardiogram to assess their heart function. As part of the echocardiogram, they will also receive a Tissue Synchronization Imaging (TSI) evaluation to assess the level of uncoordinated contraction they have. The patients will then be subjected to a cardiac exercise stress test which will involve them running on a treadmill until they cannot continue while data is collected regarding their heart's response to exercise. All portions of the study are noninvasive, which means they work from probes and monitors outside the body.
Status | Completed |
Enrollment | 25 |
Est. completion date | July 2009 |
Est. primary completion date | July 2009 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 10 Years to 21 Years |
Eligibility |
Inclusion Criteria: - between 10 and 21 years of age - structurally normal heart - congenital complete heart block - dual chamber pacemaker, right ventricular apex paced - normal function via traditional transthoracic echocardiography Exclusion Criteria: - preexisting condition that precludes patient from exercise - no informed consent |
Observational Model: Case-Only, Time Perspective: Prospective
Country | Name | City | State |
---|---|---|---|
United States | Children's Healthcare of Atlanta - Egleston | Atlanta | Georgia |
Lead Sponsor | Collaborator |
---|---|
Emory University | Children's Healthcare of Atlanta |
United States,
Bax JJ, Ansalone G, Breithardt OA, Derumeaux G, Leclercq C, Schalij MJ, Sogaard P, St John Sutton M, Nihoyannopoulos P. Echocardiographic evaluation of cardiac resynchronization therapy: ready for routine clinical use? A critical appraisal. J Am Coll Cardiol. 2004 Jul 7;44(1):1-9. Review. — View Citation
Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C, Garrigue S, Kappenberger L, Haywood GA, Santini M, Bailleul C, Daubert JC; Multisite Stimulation in Cardiomyopathies (MUSTIC) Study Investigators. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med. 2001 Mar 22;344(12):873-80. — View Citation
Ijiri H, Komori S, Kohno I, Sano S, Yin D, Takusagawa M, Iida T, Yamamoto K, Osada M, Sawanobori T, Ishihara T, Umetani K, Tamura K. Improvement of exercise tolerance by single lead VDD pacemaker: evaluation using cardiopulmonary exercise test. Pacing Clin Electrophysiol. 2000 Sep;23(9):1336-42. — View Citation
Lee MA, Dae MW, Langberg JJ, Griffin JC, Chin MC, Finkbeiner WE, O'Connell JW, Botvinick E, Scheinman MM, Rosenqvist M. Effects of long-term right ventricular apical pacing on left ventricular perfusion, innervation, function and histology. J Am Coll Cardiol. 1994 Jul;24(1):225-32. — View Citation
Saxon LA, De Marco T, Schafer J, Chatterjee K, Kumar UN, Foster E; VIGOR Congestive Heart Failure Investigators. Effects of long-term biventricular stimulation for resynchronization on echocardiographic measures of remodeling. Circulation. 2002 Mar 19;105(11):1304-10. — View Citation
Sulke N, Dritsas A, Bostock J, Wells A, Morris R, Sowton E. "Subclinical" pacemaker syndrome: a randomised study of symptom free patients with ventricular demand (VVI) pacemakers upgraded to dual chamber devices. Br Heart J. 1992 Jan;67(1):57-64. — View Citation
Thambo JB, Bordachar P, Garrigue S, Lafitte S, Sanders P, Reuter S, Girardot R, Crepin D, Reant P, Roudaut R, Jaïs P, Haïssaguerre M, Clementy J, Jimenez M. Detrimental ventricular remodeling in patients with congenital complete heart block and chronic right ventricular apical pacing. Circulation. 2004 Dec 21;110(25):3766-72. Epub 2004 Dec 6. — View Citation
Waggoner AD, Bierig SM. Tissue Doppler imaging: a useful echocardiographic method for the cardiac sonographer to assess systolic and diastolic ventricular function. J Am Soc Echocardiogr. 2001 Dec;14(12):1143-52. Review. — View Citation
Wonisch M, Lercher P, Scherr D, Maier R, Pokan R, Hofmann P, von Duvillard SP. Influence of permanent right ventricular pacing on cardiorespiratory exercise parameters in chronic heart failure patients with implanted cardioverter defibrillators. Chest. 2005 Mar;127(3):787-93. — View Citation
Yu CM, Lin H, Fung WH, Zhang Q, Kong SL, Sanderson JE. Comparison of acute changes in left ventricular volume, systolic and diastolic functions, and intraventricular synchronicity after biventricular and right ventricular pacing for heart failure. Am Heart J. 2003 May;145(5):E18. — View Citation
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04870424 -
Colchicine for Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement
|
Phase 3 | |
Completed |
NCT02548819 -
University Hospital Cardiac Device MR Registry: The Safety of MR Imaging in Patients With Implanted Cardiac Devices
|
N/A | |
Recruiting |
NCT03636230 -
Remote Patient Management of CIEDs - Brady Devices
|
N/A | |
Terminated |
NCT03859167 -
Study of the Loss of AV Synchrony at Maximum Exercise
|
||
Completed |
NCT00832988 -
CONFIRM - Comparison of in Office Interrogation Versus Remote Measurements
|
||
Completed |
NCT00294034 -
VIBRANT Registry: Value of Information Based From Pacemaker Recordings and New Technologies
|
N/A | |
Recruiting |
NCT05623527 -
Acute Cerebrovascular Events Secondary to Patients Receiving Cardiac Electronic Implants
|
||
Completed |
NCT03847298 -
Evaluation of Physical Fitness and Physical Activity Levels of Pediatric Arrhythmia Patients With Pacemaker
|
||
Completed |
NCT03843242 -
Evaluation of Ventricular Pacing Suppression Algorithms in Dual Chamber Pacemaker
|
N/A | |
Active, not recruiting |
NCT01138670 -
Complications Following Pacemaker or Implantable Defibrillator Cardioverter (ICD) Implantation in Denmark
|
N/A | |
Completed |
NCT00307073 -
Adapta Pacing System Clinical Study
|
N/A | |
Completed |
NCT04958369 -
Ultrasound-guided Axillary Versus Conventional Cephalic Venous Access for Implantation of Cardiac Devices
|
N/A | |
Completed |
NCT00631709 -
REmote MOnitoring Transmission Evaluation of IPGs
|
Phase 4 | |
Completed |
NCT01459874 -
Evaluation of an Organizational Model for Remote Monitoring of Pacemaker and Implantable Cardioverter Defibrillator Recipients
|
N/A | |
Recruiting |
NCT06356207 -
Syncope-Asystole Latency Time in Tilt Table Test: The SALT-TILT Study
|
||
Completed |
NCT03052829 -
Physical Activity and Pacemaker Study
|
N/A | |
Completed |
NCT00491777 -
Correlation Research Study: IQ2, NcIQ and IQ101
|
Phase 1 | |
Active, not recruiting |
NCT05361681 -
EMI and CIED: Is High Power Charging of Battery Electric Car Safe?
|
N/A | |
Recruiting |
NCT04201015 -
Optimising Pacing for Contractility 2
|
Phase 2/Phase 3 | |
Recruiting |
NCT03061747 -
Multi-centre Observational Registry on Patients With Implantable Devices Remotely Monitored
|
N/A |