Clinical Trial Summary

Oxygen treatment is common in management of preterm babies requiring intensive care. Delivery of too much or too little oxygen increase the risk of damage to eyes and lungs, and contributes to death and disability. Oxygen control in preterm infants requires frequent adjustments in the amount of oxygen delivered to the baby. This is generally performed manually by a clinician attending the baby, and generally directed to maintaining a specific range of blood oxygen saturation. The manual control often results in only half of the time in the specified range, with the baby experiencing high and low blood oxygen saturations. The technology being studied is designed to assist the clinician in maintaining blood oxygen saturation within target range by measuring oxygen saturation and automatically adjusting the amount of oxygen delivered for babies receiving high velocity nasal insufflation (an advanced form of high flow oxygen therapy). The proposed study will evaluate the efficacy and safety of the automatic control of oxygen by the new technology, as compared to manual control, among babies receiving high velocity therapy in a neonatal intensive care unit.


Clinical Trial Description

Detailed Description: Supplemental oxygen is commonly administered to babies in neonatal intensive care units. The goal of oxygen therapy is to maintain normal oxygenation while minimizing hypoxemia and hypoxemia. Preterm infants are particularly vulnerable to oxygen toxicity and oxidative stress leading to retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD), and periventricular leukomalacia (PVL). It's also well known that preterm infants experience hypoxic events exposing the baby to low oxygen levels. These hypoxic events vary as the infant matures, but exposure to prolonged and frequent episodes of hypoxemia is associated with increased morbidity and mortality. The delivery of oxygen is generally controlled by a clinician, and the control decisions are generally made using a non-invasive measure of blood oxygen saturation called pulse oximetry (SpO2) and is a standard of care in the neonatal intensive care unit. The most frequent item adjusted by clinicians to maintain SpO2 within specific target ranges is the fraction of the inspired oxygen (FiO2). In a recent study by Reynolds, et al., caregiver manual control of oxygen delivered to NICU babies receiving high velocity therapy resulted in only 49% of the total 24-hour study period with the babies within the target SpO2 range (90-95%). by the caregiver based on the monitored oxygen saturation. Similar to the Reynolds findings, Hagadorn et al., conducted a study in 14 centers and showed that preterm infants under 28 weeks' gestation receiving oxygen spent on average only 48% of the time with SpO2 within the prescribed target range, about 36% of the time above and 16% of the time with SpO2 below the target range. Preterm infants have frequent fluctuations in SpO2 due to their cardio-respiratory instability requiring frequent adjustments of FiO2 . Consequently, these particularly vulnerable infants spend significant time with SpO2 outside the optimal target range and are often exposed to extremes of hypoxemia and hyperoxaemia. The automatic oxygen control system continuously monitors the oxygen saturation and adjusts the oxygen delivery to maintain oxygen saturation within the target range. The efficacy of this mode of oxygen control was demonstrated by Reynolds, et al. in 2018 from two centers in the United Kingdom. Automated control of FiO2 can significantly improve compliance of oxygen saturation targeting and may significantly reduces exposure to hypoxemia as well as hyperoxaemia. The high velocity nasal insufflation therapy is a common mode of non-invasive respiratory support in preterm infants. Unlike prior studies, this study will include a set of hypothesis-driven safety endpoints (proportion of time above or below target range), stratification by body mass at enrolment, and skin pigmentation phenotype. The objective of this randomized control trial is to evaluate the efficacy of the controller (Vapotherm Oxygen Assist Module [OAM]) in maintaining the SpO2 within target range for premature infants receiving high velocity therapy and presenting with a labile FiO2 requirement. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05030012
Study type Interventional
Source Vapotherm, Inc.
Contact
Status Terminated
Phase N/A
Start date September 2, 2021
Completion date October 19, 2023

See also
  Status Clinical Trial Phase
Terminated NCT04506619 - Safety and Efficacy Outcomes Following Previously Administered Short-Term Treatment With SHP607 in Extremely Premature Infants
Completed NCT04936477 - Ventilation-perfusion (V/Q) Ratio and Alveolar Surface Area in Preterm Infants N/A
Recruiting NCT05285345 - Implementation of a Consensus-Based Discharge Protocol for Preterm Infants With Lung Disease
Completed NCT03649932 - Enteral L Citrulline Supplementation in Preterm Infants - Safety, Efficacy and Dosing Phase 1
Terminated NCT02524249 - Early Versus Late Caffeine for ELBW Newborns N/A
Completed NCT02249143 - Duration of Continuous Positive Airway Pressure and Pulmonary Function Testing in Preterm Infants N/A
Active, not recruiting NCT01632475 - Follow-Up Study of Safety and Efficacy of Pneumostem® in Premature Infants With Bronchopulmonary Dysplasia
Completed NCT01460576 - Improving Prematurity-Related Respiratory Outcomes at Vanderbilt N/A
Completed NCT00419588 - Growth of Airways and Lung Tissues in Premature and Healthy Infants
Unknown status NCT00254176 - Cysteine Supplementation in Critically Ill Neonates Phase 2/Phase 3
Completed NCT00208039 - Pilot Trial of Surfactant Booster Prophylaxis For Ventilated Preterm Neonates N/A
Completed NCT00319956 - Trial II of Lung Protection With Azithromycin in the Preterm Infant Phase 2
Completed NCT00006401 - Inhaled Nitric Oxide for Preventing Chronic Lung Disease in Premature Infants Phase 3
Completed NCT00006058 - Study of the Pathobiology of Bronchopulmonary Dysplasia in Newborns N/A
Completed NCT00005376 - Premature Birth and Its Sequelae in Women N/A
Completed NCT00011362 - Dexamethasone Therapy in VLBW Infants at Risk of CLD Phase 3
Completed NCT00004805 - Study of the Effect of Four Methods of Cardiopulmonary Resuscitation Instruction on Psychosocial Response of Parents With Infants at Risk of Sudden Death N/A
Completed NCT05152316 - The Baby Lung Study
Recruiting NCT04821453 - NAVA vs. CMV Crossover in Severe BPD N/A
Active, not recruiting NCT04662151 - A Clinical Safety Study of AT-100 (rhSP-D) in Preterm Neonates at High Risk for Bronchopulmonary Dysplasia (BPD) Phase 1