Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04415398
Other study ID # AC1
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date June 1, 2020
Est. completion date September 30, 2020

Study information

Verified date October 2020
Source Karolinska Institutet
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Time to defibrillation is the most important predictor of survival in cardiac arrest. Traditional emergency medical system response is often to slow. The aim of this study is to investigate the feasibility of drone systems that delivers Automated External Defibrillators (AED) to the scene of suspected Out-of-Hospital Cardiac Arrests (OHCA).

This study will test the feasibility of real-life flights with drones carrying automated external defibrillators (AEDs) to out-of-hospital cardiac arrest (OHCA) as a complement to standard care i.e EMS


Description:

We will test the feasibility of dispatching an out of sight AED-drone system to real-life OHCA in parallel with standard EMS dispatch. The study period is 5 months between May to September 2020. The study area will be covered by three individual drone systems covering some 80,000 inhabitants within the controlled airspace of Säve airport in Göteborg Sweden. Each drone system will have a flight range of six km.

The first month of the study period will be used as run-in period and the drone systems are dispatched for beyond visual line of sight (BVLOS) flights in a simulated fashion and optimized to decrease delays and to log pre-specified system variables, adherence to protocol, time delays, technological functionality, weather conditions, conflict in the airspace.

During the following 4 months June-September 2020, drones will dispatched to real-life suspected OHCA during daytime 08:00-22:00.

An EMS communication radio-unit is placed at the drone control center. In case of a suspected OHCA in the service area and will be alerted by the dispatch centre (SOS alarm) when a suspected OHCA is recognized during the 112-call.

- The dispatcher identifies a cardiac arrest in the service areas

- A pilot (from Everdrone) immediately initiates deployment protocol for the drone.

- Parallel communication is made with the air traffic control (ATC) centre in order to grant permit to deploy the drone with regards to the current weather and aviation situation.

- The drone then flies to the coordinates of the OHCA and delivers an AED at the scene using a winch system

- The AED may be attached to the patient by the bystander on scene

Development of the technology is made by Everdrone AB Göteborg and SOS Alarm AB (national dispatch organisation) and parallel applications for certificates for the individual aircraft and permits for beyond visual line of sight flights (BVLOS-flights) was granted by the Swedish Transportation board on 27 April 2020.

The drone system is operated only during daytime 08:00-22:00 when the Airport Air traffic control is open. Likewise deployment of the drone will not be made if there is a conflict in the airspace with manned aircrafts. Rainy weather or winds exceeding 8 m/s prohibits flights as well.

Feasibility is evaluated and measured from the following aspects:

1. Operational factors Weather: a) rain, b) wind c) other. Conflict in airspace: a) manned aircraft b) unmanned aircraft. Obstacles prohibiting flight or delivery: a) constructed b) natural Time from dispatch to to take- off (min:sec). Time from dispatch to arrival (min:sec). Proportions are measured out of cases with a) Take-off b) no take-off c) aborted missions (%)

2. Human resources Adherence to protocol by: a) Dispatcher b) Drone pilot c) Air traffic leader. Proportions are measured out of cases with neglected protocol prohibiting mission completion, a) no alerts b) no take off c) aborted missions (%)

3. Technological functionality Drone, winch, Network, AED, Hangar, navigational software, global positioning system precision, Dispatch centre system (CoordCOM -Dispatch centre automated alert).

Proportions are measured out of cases where technological functionality prohibited mission completion a) no take-off b) aborted missions. (%)

Adverse advents (AE) and serious adverse events (SAE) in relation to AED-drone mission /use will be logged continuously. An adverse event may be caused by drone crash or risc of injury or death due to conflict in airspace or technological impairment.

An AE is considered serious if it:

- Results in death

- Is immediately life-threatening

- Requires hospitalisation or prolongation of existing hospitalization

- Results in persistent or significant disability or incapacity

Events that are related to the patient in cardiac arrest and would be expected in patients undergoing attempted resuscitation should NOT be reported. These include:

- Death

- Hospitalisation

- Persistent or significant disability or incapacity

- Organ failure

All events categorised as serious must be reported to the study administration within 24 hours of becoming aware of the event.


Recruitment information / eligibility

Status Completed
Enrollment 12
Est. completion date September 30, 2020
Est. primary completion date September 30, 2020
Accepts healthy volunteers No
Gender All
Age group 8 Years and older
Eligibility Inclusion Criteria:

- All suspected OHCA

- Within n=3 service areas

- Hours of operation: 08:00-22:00

Exclusion Criteria:

- Children <8 years

- Trauma

- EMS-witnessed cases

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Automated flying Drone carrying an Automated external defibrillator (AED)
Totally n=3 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over 4 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation.

Locations

Country Name City State
Sweden Göteborg AED-drone service areas Göteborg

Sponsors (3)

Lead Sponsor Collaborator
Karolinska Institutet Everdrone AB, SOS Alarm Sverige AB

Country where clinical trial is conducted

Sweden, 

Outcome

Type Measure Description Time frame Safety issue
Primary Proportion of suspected OHCA cases (%) where the AED-drone was dispatched and accurately completed mission. All cases of OHCA within the three service areas where the dispatch centre alerts the drone-operator and the drone takes-off. Accurate completion of mission equals deliver an AED onsite on the ground within 50 meters from OHCA location. AEDs shall be accessible to the bystander through T-CPR instructions given by the dispatcher. Up to 4 months
Secondary Proportion of suspected OHCA with AED-drone arrival prior to ambulance Comparisons on proportion of units arriving first to the scene for ambulance vs AED-drone, percentages. Up to 4 months
Secondary Time difference of drone arrival as compared to ambulance Time delay from dispatch to arrival (delivered AED on ground), minutes, seconds. Up to 4 months
Secondary Proportion/numbers of attached drone delivered AEDs prior the arrival of EMS (%). A bystander retrieves the AED as instructed in T-CPR protocol by the dispatcher and attaches it to the patient before ambulance arrival. Percentages. Up to 4 months
See also
  Status Clinical Trial Phase
Recruiting NCT05434910 - Blood Pressure and Cerebral Blood Flow After Cardiac Arrest N/A
Active, not recruiting NCT03700125 - Pre-hospital ECMO in Advanced Resuscitation in Patients With Refractory Cardiac Arrest. ( SUB30 ) N/A
Completed NCT02527694 - CPR Quality Between Flexible Stretcher and Standard Stretcher in OHCA N/A
Completed NCT02899507 - Prophylactic Antibiotics in Comatose Survivors of Out-of-hospital Cardiac Arrest Phase 4
Recruiting NCT02184468 - Survival Study After Out-of-hospital Cardiac Arrest N/A
Completed NCT04085692 - Dispatcher-Assisted CPR: Low-Dose, High-Frequency Simulation-Based Training N/A
Recruiting NCT05029167 - REstrictive Versus LIberal Oxygen Strategy and Its Effect on Pulmonary Hypertension After Out-of-hospital Cardiac Arrest (RELIEPH-study) N/A
Completed NCT04080986 - DOuble SEquential External Defibrillation for Refractory VF N/A
Completed NCT04058925 - Tissue Oxygenation During Cardiopulmonary Resuscitation as a Predictor of Return of Spontaneous Circulation
Enrolling by invitation NCT05113706 - Does Bystanders Emotional State Influence Dispatcher-assisted Cardiopulmonary?Resuscitation
Completed NCT04219306 - Machine Learning Assisted Recognition of Out-of-Hospital Cardiac Arrest During Emergency Calls. N/A
Completed NCT03881865 - P25/30 SSEPs and Neurological Prognosis After Cardiac Arrest
Recruiting NCT04993716 - Epidemiological Study on the Management of Out-of-hospital Cardiac Arrest Survivors in Champagne ArDEnnes
Completed NCT05062785 - Dose-Finding Study of Intranasal Insulin in Healthy Participants Insulin in Healthy Participants Phase 1
Recruiting NCT06122337 - Systemic Evaluation of the Etiologies of Young Adults With Non-traumatic Out-of-hospital Cardiac Arrest
Not yet recruiting NCT04584463 - Factors Associated With CPC 1-2 in 110 Patients Admitted in French ICU for a Myocardial Infarction Complicated by an OHCA.
Recruiting NCT03355885 - Early-onset Pneumonia After Out-of-hospital Cardiac Arrest N/A
Recruiting NCT05132387 - Wroclaw Out-Of-Hospital Cardiac Arrest Registry
Recruiting NCT02827422 - A Prospective, Multicenter Registry With Targeted Temperature Management After Out-of-hospital Cardiac Arrest in Korea N/A
Completed NCT02646046 - Combining Performance of Call EMS and Simultaneous Chest Compressions in a Lone Rescuer CPR N/A