Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to compare objective and subjective measures of knee stability following total knee arthroplasty with a medial pivot design vs. a posterior stabilized design.


Clinical Trial Description

Several different prostheses are available for use in total knee arthroplasty (TKA). These designs aim to replicate the normal kinematics of the knee joint while maintaining stability throughout a full range of motion. The posterior cruciate ligament (PCL) contributes to these functions in the native knee, and if preserved it can function similarly in the prosthetic knee. Prostheses in which the PCL is sacrificed, and its function not replaced by other means, have poorer outcomes. However, various problems with preserving the PCL, including PCL deterioration in arthritic knees and difficulties with proper tensioning, have led to the development of alternative ways to emulate normal femoral rollback and sagittal plane stability. These posterior-substituted (PS) designs substitute for the PCL with either a cam and post mechanism or a symmetrical ultra-congruent tibial insert. The cruciate-retaining (CR) and PS designs, together with advances in surgical techniques and component materials, have achieved excellent implant survivorship with rates of > 90% at 20 years. Reports of functional outcomes, however, have been variable. One potential area for improvement in TKA is optimization of implant design to better approximate native knee kinematics. In the normal knee, the medial condyle remains stable in the sagittal plane, functioning like a ball-and-socket, whereas the lateral condyle translates anterior to posterior during flexion. The designs of the CR and PS knees do not allow for this medial-centered rotation. Analysis has revealed paradoxical anterior sliding of the femur during flexion, abnormal axial rotation, and condylar lift-off. Edge loading and increased sagittal plane motion may predispose to accelerated polyethylene wear. The posterior stabilized design uses a cam-and-post mechanism in which one piece of the prosthesis has a plastic post that fits into a slot in the other piece of the prosthesis. A newer design that attempts to address these issues is the medial pivot knee (MP). This design is characterized by an asymmetrical tibial insert in which the medial compartment is ultra-congruent, providing antero-posterior stability and the lateral compartment allows for rollback around a medial axis of rotation i.e uses a ball-and-socket mechanism. This design more accurately recreates normal knee kinematics, reduces anteroposterior instability, and avoids condylar lift-off. Early studies indicate improved polyethylene wear characteristics. Midterm studies report excellent implant survivorship and clinical outcomes. Several randomized trials have compared the MP knee favorably with other designs. Patients with bilateral TKAs with a different prosthesis on each side preferred their medial pivot knee to a PS, CR, or mobile-bearing (MB) design. A trial comparing the MP and PS designs found greater range of motion (ROM) and better patient-reported outcomes in the MP group at 2 years. There also exists literature reporting poorer outcomes with the MP design. A trial involving 96 patients who had received both an MP knee and an MB knee on contralateral sides found lower ROM, higher complication rates, and worse patient reported outcomes in the MP knee. Given the lack of consensus in the literature, further investigation is warranted to determine the impact of the MP design on outcomes following TKA. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02577978
Study type Interventional
Source Northwestern University
Contact
Status Completed
Phase N/A
Start date April 2014
Completion date June 2017

See also
  Status Clinical Trial Phase
Not yet recruiting NCT03274713 - Efficacy of Electro-acupuncture Versus Manual Acupuncture on Knee Osteoarthritis N/A
Completed NCT04535596 - Blood Flow Restriction Exercises and Conservative Exercises in Knee Osteoarthritis N/A
Completed NCT03918291 - Whole-body Vibration Training on Functional Performance of the Elderly With Knee Osteoarthritis N/A
Recruiting NCT06263517 - Clinical Trial to Assess Efficacy, Tolerability of Rising Doses of Clodronate in Painful Knee Osteoarthritis Patients Phase 2/Phase 3
Completed NCT01453738 - Allogeneic Mesenchymal Stem Cells in Osteoarthritis Phase 2
Active, not recruiting NCT01027819 - Comparison of Outcomes in Mobile and Fixed-bearing Total Knee Arthroplasty Phase 4
Completed NCT01186211 - Feasibility of Outpatient Total Knee Arthroplasty
Active, not recruiting NCT00261066 - Outcome Following Orthopaedic Surgery
Completed NCT03484910 - Biofeedback With Cycling Exercise in OA Knee Patients N/A
Recruiting NCT03884374 - Pain Relief for OsteoArthritis Through Combined Treatment (PROACT) N/A
Completed NCT03492320 - Progression of Health Related Quality of Life of Patients Waiting for Total Knee Arthroplasty
Completed NCT01449552 - Temporary Clamping of Drains Combined With Tranexamic Acid Reduce Blood Loss After TKA: A Prospective RCT N/A
Completed NCT06254976 - Serum Nesfatin-1 and Human Cartilage Glycoprotein-39 Levels in Knee Osteoarthritis N/A
Completed NCT03428893 - Mobile Technology to Support Physical Therapy Exercise N/A
Completed NCT05081921 - Clinical Trial to Evaluate Safety and Efficacy of MesoCellA-Ortho Tissue-Engineered Advanced Therapy Product in Patients With Osteoarthrosis and Civilisation Diseases Phase 1/Phase 2
Completed NCT02850068 - Geniculate Artery Embolization for the Treatment of Knee Pain N/A
Active, not recruiting NCT03110172 - Short-term Efficacy of Antidepressant in Patients Underwent TKA Phase 1/Phase 2
Enrolling by invitation NCT02623660 - Microcurrent Stimulation Reduces Post-Operative Swelling and Healing Time Following Knee Replacement Surgery N/A
Completed NCT02579174 - Total Knee Replacement Component Alignment Using Manual Versus Custom Instrumentation N/A
Completed NCT00790985 - Efficacy of Flavocoxid 500 mg Compared With Naproxen 500 mg in Subjects With Moderate-severe Osteoarthritis of the Knee N/A