Image Guided Surgical System for Orthopaedic Trauma
This project focuses on the further development and clinical testing of an image-guided
surgical system. The system will help surgeons perform procedures that involve inserting a
screw, guide pin, drill bit, or other straight object into bone-for example, inserting
screws in a broken hip bone. These surgeries are currently done with the help of a mobile
x-ray device called a C-arm, which provides the surgeon with x-ray images during the
procedure.
C-arms have some disadvantages, including image distortion, radiation exposure, and the need
for time-consuming adjustments of the C-arm during the surgery. The new method would deal
with these shortcomings with a computer-based system that adds to the existing C-arm system.
It would provide the surgeon with a real-time view of the insertion process, and could
improve the accuracy and speed of certain surgical procedures.
Disadvantages associated with C-arms include image distortion, radiation exposure, and time
consuming reconfiguration of the C-arm during the insertion process. The proposed system
would address these shortcomings with a computer-based system that augments the existing
C-arm system.
This Small Business Innovation Research Phase II project supports the further development
and clinical testing of an image-guided surgical system that will assist the surgeon in
performing procedures that involve the insertion of a screw, guide pin, drill bit, or other
linear object into bone. These surgeries are currently performed with the assistance of a
mobile fluoroscopic x-ray imager known as a C-arm.
Disadvantages associated with C-arms include image distortion, radiation exposure, and
time-consuming reconfiguration of the C-arm (between A/P and lateral views) during the
insertion process. The proposed system would address these shortcomings with a
computer-based system that augments the existing C-arm system. The new system uses an
optical localizer (a stereo camera device that tracks light-emitting diodes) to monitor the
location and orientation of a drill guide in the surgical field. The drill guide trajectory
is then graphically superimposed on the x-ray images. This provides real-time, on-screen
positional feedback to the surgeon to improve the accuracy and speed with which certain
procedures involving insertion of drill bits or guide pins can be performed. The research
effort will focus on the development of a clinical prototype and its evaluation by several
quantitative and qualitative methods.
The commercial success of such a system depends on its acceptance by surgeons, which in turn
depends on the extent to which it is a tool that provides better information to the surgeons
without intruding on a procedure in which they are already highly skilled. Commercial
success also depends on the ability of the system to reliably save time in the operating
room. We will address these issues with cadaveric studies and subsequent clinical trials.
Proposed Commercial Applications: The initial commercial application of this system is the
insertion of dynamic compression hip screws in cases of hip fracture. Because this is a
common fracture, any reduction in surgical time has great potential for cost savings. Other
advantages include decrease in radiation exposure and the potential reduction of serious
complications. Minor modifications that allow the system to assist with numerous other
orthopaedic trauma procedures are already planned.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind, Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02422355 -
A Focused Registry on the Femoral Neck System (FNS) in Patients With Femoral Neck Fractures
|
||
Completed |
NCT02197065 -
Pilot Study of Atorvastatin for Orthopedic Surgery Patients
|
Phase 2 | |
Recruiting |
NCT01934946 -
Rehabilitation Care for Hip Fracture
|
N/A | |
Completed |
NCT01714336 -
Does Tranexamic Acid Reduce the Need for Blood Transfusions in Patients Undergoing Hip Fracture Surgery?
|
Phase 4 | |
Terminated |
NCT01667913 -
Reliability of 6-Minutes Walking Test in Hip Fracture Patients
|
N/A | |
Terminated |
NCT01535781 -
Study of the Effect of Tranexamic Acid Administered to Patients With Hip Fractures. Can Blood Loss be Reduced?
|
N/A | |
Completed |
NCT01174589 -
Training of Patients With Hip Fracture
|
Phase 2 | |
Active, not recruiting |
NCT02362971 -
External Validity of a Randomized Trial in Patients With a Femoral Neck Fracture
|
N/A | |
Completed |
NCT02591342 -
Comparison of a Cemented, Polished Tapered Stem and an Anatomic Stem for Femoral Neck Fracture
|
N/A | |
Completed |
NCT01738776 -
Nutritional Risk Factors for Hip Fracture: a Case Control Study
|
N/A | |
Completed |
NCT01382875 -
The Comparison of Comprehensive Multi-disciplinary Program and Conventional Care Program on Fragility Fracture Elderly
|
Phase 3 | |
Suspended |
NCT00521716 -
Safety and Efficacy of the WaisFix100i for Intracapsular Femoral Fracture Fixation
|
N/A | |
Terminated |
NCT00128115 -
Treatment of Sarcopenia in Post-Hip Fracture Patients (0677-032)
|
Phase 2 | |
Active, not recruiting |
NCT00345488 -
Fast Track Admittance of Hip Fracture Patients
|
Phase 4 | |
Completed |
NCT02409082 -
Alzheimers Disease and Neuromarkers in Patients With Acute Hip Fractures
|
N/A | |
Recruiting |
NCT04626934 -
Cognitive Intervention and Rehabilitation Outcomes in Hip Fracture Patients
|
N/A | |
Completed |
NCT06001996 -
Comparison of Intraoperative- Postoperative Effects of Pericapsular Nerve Block and Fascia Iliaca Block in Hip Fracture
|
||
Recruiting |
NCT02635763 -
Peripheral Nerve Blocks in Elderly Patients With Hip Fracture
|
N/A | |
Completed |
NCT00848913 -
Strength Training After Hip Fracture Surgery
|
N/A | |
Completed |
NCT02190903 -
A Trial To Assess Risk of Delirium in Older Adults Undergoing Hip Fracture Surgery With Spinal or General Anesthesia
|
N/A |