Background Correction of post traumatic and post-ablative orbita defects remains a challenge for the maxillofacial surgeon. The purpose of such intervention is the restoration of both function and aesthetics by anatomical reconstruction of the bony orbitawalls, with attention to the orbitavolume. Unfortunately, the results of such interventions today are still somewhat unpredictable.

The aim of this study is to determine whether 3D virtual planning combined with intra-operative navigation can increase the predictability of the outcome in function and aesthetics.

Study design Retrospective study. Demographic data, diagnostic and surgical parameters will be collected of all patients undergoing orbital surgery between 01/01/2012 and 31/12/2016 at the department. Pre- en postoperative orbit volume will be determined based on CT-analysis in Brainlab software, and compared to the non-defected orbit.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03057405
Study type Observational
Source AZ Sint-Jan AV
Contact
Status Completed
Phase
Start date October 2016
Completion date January 10, 2019

See also
  Status Clinical Trial Phase
Terminated NCT03673865 - The Use of 3D Printing in Orbital Fractures N/A
Completed NCT00584506 - Computer Aided Evaluation of Orbital Volume N/A
Recruiting NCT03887988 - Orbital Fractures Registry
Not yet recruiting NCT04271137 - Correction of Enophthalmos and Orbital Volume Using Pre-bent Mesh Versus 3d Printed Onlay in Orbital Fracture Cases N/A
Completed NCT02736461 - Factors Associated With Postoperative Strabismus After Floor Fracture Repair N/A
Completed NCT00233922 - Reconstruction of the Orbit With a Bioresorbable Polycaprolactone Implant Phase 2
Withdrawn NCT01504568 - The Use of Prophylactic Antibiotics in Isolated Blowout Fractures N/A
Not yet recruiting NCT03813732 - Using the Transconjuctival Approach Alone Versus Using it Together With Lateral Canthotomy in Orbital Fractures N/A
Recruiting NCT01464541 - Orbital Fractures Measurement: Intraoperative Versus Computed Tomography (CT) Scan N/A
Completed NCT01432964 - Use of a Low Profile Titanium Mesh in Orbital Reconstruction N/A
Enrolling by invitation NCT06294535 - The Accuracy of Reconstruction of Orbital Walls Fracture Using Prebent Mesh Versus Patient Specific Implant N/A
Recruiting NCT04704414 - Exophthalmometry With 3D Face Scanners N/A
Completed NCT05439512 - Orbital Floor Fracture Repair by Titanium Mesh Via Transantral Approach. N/A
Recruiting NCT06369129 - Accuracy& Orbital Volume Using Patient Specific Titanium Implant Vs Zirconia for Orbital Floor Reconstruction N/A