Orbital Fractures Clinical Trial
Official title:
Reconstruction of the Orbit With a Bioresorbable Polycaprolactone Implant
Patients with orbital injuries are entered into the trial. Age: 20 - 70. After obtaining appropriate consent, they are entered into either a control arm where reconstruction of the orbit is done with a titanium mesh (established practice) or the experimental arm where reconstruction is by a bioresorbable implant made of polycaprolactone. Patients are followuped at 1 week, 1 month, 3 months, 6 months & 12 months. CT scan of the orbits are performed preop, 6 months & 12 months. End point is the 12 month follow-up appointment. Visual acuity, range of motion, enophthalmos & diplopia are assessed in follow-up.
Patients with orbital injuries are entered into the trial. Age: 20 - 70. After obtaining appropriate consent, they are entered into either a control arm where reconstruction of the orbit is done with a titanium mesh (established practice) or the experimental arm where reconstruction is by a bioresorbable implant made of polycaprolactone. Patients are followuped at 1 week, 1 month, 3 months, 6 months & 12 months. CT scan of the orbits are performed preop, 6 months & 12 months. End point is the 12 month follow-up appointment. Visual acuity, range of motion, enophthalmos & diplopia are assessed in follow-up. ;
Allocation: Randomized, Endpoint Classification: Bio-equivalence Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03057405 -
Intra-operative (IO) Navigation and IO-CBCT for 3D Orbital Reconstruction
|
||
Terminated |
NCT03673865 -
The Use of 3D Printing in Orbital Fractures
|
N/A | |
Completed |
NCT00584506 -
Computer Aided Evaluation of Orbital Volume
|
N/A | |
Recruiting |
NCT03887988 -
Orbital Fractures Registry
|
||
Not yet recruiting |
NCT04271137 -
Correction of Enophthalmos and Orbital Volume Using Pre-bent Mesh Versus 3d Printed Onlay in Orbital Fracture Cases
|
N/A | |
Completed |
NCT02736461 -
Factors Associated With Postoperative Strabismus After Floor Fracture Repair
|
N/A | |
Withdrawn |
NCT01504568 -
The Use of Prophylactic Antibiotics in Isolated Blowout Fractures
|
N/A | |
Not yet recruiting |
NCT03813732 -
Using the Transconjuctival Approach Alone Versus Using it Together With Lateral Canthotomy in Orbital Fractures
|
N/A | |
Recruiting |
NCT01464541 -
Orbital Fractures Measurement: Intraoperative Versus Computed Tomography (CT) Scan
|
N/A | |
Completed |
NCT01432964 -
Use of a Low Profile Titanium Mesh in Orbital Reconstruction
|
N/A | |
Enrolling by invitation |
NCT06294535 -
The Accuracy of Reconstruction of Orbital Walls Fracture Using Prebent Mesh Versus Patient Specific Implant
|
N/A | |
Recruiting |
NCT04704414 -
Exophthalmometry With 3D Face Scanners
|
N/A | |
Completed |
NCT05439512 -
Orbital Floor Fracture Repair by Titanium Mesh Via Transantral Approach.
|
N/A | |
Recruiting |
NCT06369129 -
Accuracy& Orbital Volume Using Patient Specific Titanium Implant Vs Zirconia for Orbital Floor Reconstruction
|
N/A |