Orbital Fractures Clinical Trial
Official title:
Assessment of Accuracy and Orbital Volume Using Patient Specific Titanium Implant Vs Patient Specific Zirconia Implant for Orbital Floor Reconstruction in Blowout Fractures A Randomized Clinical Trial: Comparative Study
Comparative study used to assess if the patient specific zirconia implant will provide better accuracy, intraoperative adaptability, precise orbital volume and soft tissue reaction with more cost effectiveness than the patient specific titanium implants in orbital floor reconstruction after blow out fractures .
Patients of both groups will be subjected to: 1. Case history including personal data, medical, surgical history and family history. 2. A full examination of the cranial and maxillofacial skeleton and soft tissue . 3. Evaluation of Visual Functions 4. Ophthalmologic consultation and clearance 5. Radiographic examination: CT scan 6. All DICOM data will be imported to the surgical planning software. Virtual planning: 1. A midsagittal plane will be constructed then the normal orbit will be mirrored to the affected side. 2. The mirrored orbital floor will be meshed with 1.6 mm holes then its peripheries will be extended downwards by 3 mm and meshed also in order to accommodate the fixation. 3. The designed part will be subtracted then exported in Stereolithography (STL) format to be fabricated . The surgery will be done under General anesthesia and undertaken within 14 days to prevent fibrosis. Can be delayed 24-72 hours to allow the edema to subside before undertaking surgery. Intervention Group: - • The STL file will be milled from zirconium and then will be ready for sterilization and intraoperative fixation - A transconjunctival incision will be done to allow for good exposure that optimizes visualization of the orbital floor during the repair and insertion and fixation of the patient specific zirconia implant. Control Group: - • The STL file be milled from grade 4 titanium and then will be ready for sterilization and intraoperative fixation with the same surgical steps. Follow up: All patients will be examined clinically and radiographically, during postoperative 1st and 2nd week . Only one postoperative CT scan will be done after 2 weeks. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03057405 -
Intra-operative (IO) Navigation and IO-CBCT for 3D Orbital Reconstruction
|
||
Terminated |
NCT03673865 -
The Use of 3D Printing in Orbital Fractures
|
N/A | |
Completed |
NCT00584506 -
Computer Aided Evaluation of Orbital Volume
|
N/A | |
Recruiting |
NCT03887988 -
Orbital Fractures Registry
|
||
Not yet recruiting |
NCT04271137 -
Correction of Enophthalmos and Orbital Volume Using Pre-bent Mesh Versus 3d Printed Onlay in Orbital Fracture Cases
|
N/A | |
Completed |
NCT02736461 -
Factors Associated With Postoperative Strabismus After Floor Fracture Repair
|
N/A | |
Completed |
NCT00233922 -
Reconstruction of the Orbit With a Bioresorbable Polycaprolactone Implant
|
Phase 2 | |
Withdrawn |
NCT01504568 -
The Use of Prophylactic Antibiotics in Isolated Blowout Fractures
|
N/A | |
Not yet recruiting |
NCT03813732 -
Using the Transconjuctival Approach Alone Versus Using it Together With Lateral Canthotomy in Orbital Fractures
|
N/A | |
Recruiting |
NCT01464541 -
Orbital Fractures Measurement: Intraoperative Versus Computed Tomography (CT) Scan
|
N/A | |
Completed |
NCT01432964 -
Use of a Low Profile Titanium Mesh in Orbital Reconstruction
|
N/A | |
Enrolling by invitation |
NCT06294535 -
The Accuracy of Reconstruction of Orbital Walls Fracture Using Prebent Mesh Versus Patient Specific Implant
|
N/A | |
Recruiting |
NCT04704414 -
Exophthalmometry With 3D Face Scanners
|
N/A | |
Completed |
NCT05439512 -
Orbital Floor Fracture Repair by Titanium Mesh Via Transantral Approach.
|
N/A |