Clinical Trials Logo

Clinical Trial Summary

Robot-assisted laparoscopic radical prostatectomy (RALRP) is becoming a popular procedure due to its unique advantages.

Despite these advantages, pneumoperitoneum and steep trendelenburg position are associated with hemodynamic instability and elevated intracranial pressures (ICP).

Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is an indirect but also a generally accepted reliable and noninvasive measurement of elevated ICP. However, optimal cut-off values are highly inconsistent due to multiple factors (gender, height, weight). To eliminate the effects of these factors on the results; a ratio should be established in patients known to have elevated ICPs.

In a recent study ONSD/ eyeball transverse diameter(ETD) in healthy volunteers in a specific population was established.

60 patients without any history of ICP undergoing RALRP will be enrolled to the study. Ultrasonographic measurement of ONSD and ETD will be performed 10 minutes after induction of general anesthesia, 10 minutes after CO2 pneumoperitoneum with trendelenburg positioning and measurements will be repeated hourly and at last after returning to supine position without CO2 pneumoperitoneum at the end of the procedure.

Hemodynamic variables and BIS values on this specific times will be recorded and an arterial sample will be obtained.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03691025
Study type Observational
Source Hacettepe University
Contact Basak Akça
Phone 00905322275451
Email drbasakakca@gmail.com
Status Not yet recruiting
Phase
Start date October 15, 2018
Completion date March 1, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT02697825 - Intraocular Pressure Versus Optic Nerve Sheath Diameter N/A
Not yet recruiting NCT05485363 - Non-invasive Assessment of Intracranial Pressure Using Ocular Sonography in Patients Undergoing Laparoscopic Sleeve Gastrectomy N/A
Not yet recruiting NCT04092036 - Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
Completed NCT03362255 - Measurement of Optic Nerve Sheath Diameter N/A
Completed NCT04412109 - Optic Nerve Sheath Diameter Difference Between Different Injection Volume N/A
Completed NCT04826042 - Effect of Contrast Medium on Optic Nerve Sheath Diameter N/A
Completed NCT03152981 - Analysis of Change of Optic Nerve Sheath Diameter in Robot Assisted Laparoscopic Radical Prostatectomy N/A
Completed NCT03131245 - Optic Nerve Sheath Diameter in Craniosynostosis
Recruiting NCT04910087 - The Effect of Anesthesia Management on Optic Nerve Sheath Diameter in the Ercp Procedures N/A
Recruiting NCT04507620 - Effect of Cervical Immobilization on Optic Nerve Sheath Diameter
Recruiting NCT06187714 - Effect of Caudal Block Injection Rate on Optic Nerve Sheath Diameter in Pediatric Surgeries
Completed NCT04955925 - Effect of Sevoflurane and Propofol on the Optic Nerve Sheath Diameter
Not yet recruiting NCT04427085 - Changes of Optic Nerve Sheath Diameter Between Obese and Non-obese Patients Undergoing Laparoscopic Gynecological Surgery N/A
Completed NCT04765397 - Different Resectoscopes Effects to Optic Nerve Sheath Diameter N/A
Completed NCT05499754 - Effect of Different Supralottic Airway Devicess on Optic Nerve Sheath Diameter
Recruiting NCT06254534 - Lidocaine, Dexmedetomidine, Esmolol and Magnesium Effect on Optic Nerve Sheath Diameter After Laryngoscopy N/A
Completed NCT05690087 - Lidocaine Infusion on Optic Nerve Sheath Diameter in Laparoscopic Hysterectomy in Trendelenburg Position N/A
Completed NCT03634176 - Optic Nerve Sheath Diameter in Retrobulbar Ultrasound as a Surrogate Measure for Intracranial Pressure Before and After Non-invasive Strategies
Recruiting NCT06209034 - Intraoperative Optic Nerve Sheath Diameter Changes After Laparoscopic Surgery N/A
Recruiting NCT05610774 - Optic Nerve Sheath Diameter in Pre-Eclamptic Parturient Receiving Magnesium Sulfate Combined With Dexmedetomidine N/A