Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05097612
Other study ID # ETH EK 2021-N-151
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date November 8, 2021
Est. completion date January 31, 2022

Study information

Verified date November 2023
Source Swiss Federal Institute of Technology
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

In this study the LiftSuit version 2.0 designed by Auxivo AG will be used. The LiftSuit is a soft wearable device that is designed to support workers perform physically demanding tasks including repetitive lifting and working in forward leaning positions. It is put on like a backpack and attached to the body using fabric bands and cuffs. Besides soft fabric parts the LiftSuit contains elastics elements. The elastic elements can be flexibly exchanged by the experimenter. For this experiment elastic elements of known stiffness will be hooked into the fabric frame.


Description:

In a first step participants will try on the LiftSuit exoskeleton and adjust it to their body under supervision of the experimenter. When the LiftSuit exoskeleton is adjusted to the participant it is taken off to allow placement of sensors. The sensors used to record heart rate (Polar H9 heart rate monitor, Polar Electro Europe AG, Germany), muscle activity from 8 muscles in the back and hip region (Delsys Trigno, Delsys Europe, United Kingdom) and movement kinematics (OptiTrack motion capture system, NaturalPoint Inc., USA) will be placed by the experimenter (or participant him/herself). To verify that the electromyography sensors, are working and to obtain normalization values, participants will be instructed to conduct maximal voluntary contractions of each muscle that are being recorded. If needed single sensors can be replaced. After this the exoskeleton will be put back on.


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date January 31, 2022
Est. primary completion date January 31, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 65 Years
Eligibility Inclusion Criteria: - Included will be volunteers of both sexes within working age (18 to 65 years). Exclusion Criteria: - Participants will be excluded if they cannot perform the tasks (squat lifting and forward leaning) due to physical limitations. Furthermore, people who report acute joint or muscle pain or stiffness, or a self-reported history of such problems will be excluded.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Placebo LiftSuit Exoskeleton
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). In this condition the EES are removed from the device to create a placebo device.
LiftSuit Exoskeleton (low support level)
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.
LiftSuit Exoskeleton (medium support level)
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.
LiftSuit Exoskeleton (high support level)
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.

Locations

Country Name City State
Switzerland ETH Zurich, Rehabilitation Engeineering Laboratory Zurich

Sponsors (2)

Lead Sponsor Collaborator
Swiss Federal Institute of Technology Auxivo AG

Country where clinical trial is conducted

Switzerland, 

Outcome

Type Measure Description Time frame Safety issue
Other Change in muscle activity of abdominal muscles (placebo comparator - experimental intervention) An elastic band placed external to the body over the hip joint is likely to support the muscles that extend the hip. It could be that this setup might heightened levels of activity in the abdomen. 2 hours
Other Change in hip angle kinematics (placebo comparator - experimental intervention) Changed forces around the hip joint might influence movement kinematics of this joint. Changes in position and acceleration of the joint angle will be calculated. 2 hours
Primary Change in muscle activity of hip extensor muscles (placebo comparator - low support experimental intervention) An elastic band placed external to the body parallel to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less hip extensor muscle (m. gluteus maximus, hamstrings) activity is expected in LiftSuit conditions compared to the placebo comparator condition. 2 hours
Primary Change in muscle activity of back extensor muscles (placebo comparator - low support experimental intervention) An elastic band placed external to the body paralell to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less back muscle activity (erector spinae at lumbar and thoracic level) is expected in LiftSuit conditions compared to the placebo comparator condition. 2 hours
Secondary Change in muscle activity of hip extensor muscles related to stiffness level of the Elastic Energy Storages (low, medium, high stiffness). A reduction in muscle activity is expected. This reduction is expected to be related to the stiffness level of the EES. With high stiffness, leading to more support, leading to less muscle activity. 2 hours
Secondary Change in muscle activity of back muscles related to stiffness level of the Elastic Energy Storages (low, medium, high stiffness). The reduction in muscle activity is expected to be related to the stiffness level of the EES. With high stiffness, leading to more support, leading to less muscle activity. 2 hours
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05006976 - A Naturalistic Trial of Nudging Clinicians in the Norwegian Sickness Absence Clinic. The NSAC Nudge Study N/A
Not yet recruiting NCT03678519 - Occupational Health Hazards Among Flour Mills Workers
Completed NCT02985164 - Radiation Exposure During Endoscopic Retrograde Cholangiopancreatography Phase 3
Completed NCT05507944 - FeNO Hairdressers Pilot
Enrolling by invitation NCT05766397 - Prehospital Inhaled Methoxyflurane Non-Clinical Occupational Exposure Study Phase 4
Completed NCT05511896 - Effects of a 60-min Repeated Trunk Flexion Protocol on Trunk Neuromuscular Properties. N/A
Completed NCT03002987 - Active Pregnancy Policy at Work. Greater Wellbeing and Lower Sickness Absence N/A
Active, not recruiting NCT03048630 - Reducing Chemical Exposures in Nail Salons N/A
Completed NCT04591756 - Effectiveness of Respiratory Protection During Simulated Resuscitation: a Prospective Cohort Study N/A
Completed NCT04075279 - Heart at Work Study
Enrolling by invitation NCT05651477 - Relationship Between Health Risk and Occupational Exposure of ED
Completed NCT02661074 - Anisakis Blastocystis Cryptosporidium Fish Prevalence N/A
Completed NCT05811767 - The Esbjerg Cohort - A Cross-sectional Study About Work Ability and Musculoskeletal Pain in 55 to 70 Years Old Workers
Completed NCT00342394 - Fungicide Exposure Assessment Among Apple and Peach Farmers in the Argicultural Health Study
Not yet recruiting NCT03695302 - Knowledge , Attitude and Practice (KAP) of Fifth Year Undergraduate Dental Students on Post Exposure Prophylaxis
Recruiting NCT05849168 - High-Intensity Interval Training to Improve Symptoms of Deployment-Related Respiratory Disease N/A
Completed NCT04879082 - Identification Of Occupational Exposures In Patients With ILD
Recruiting NCT06193018 - Ergonomic Effects of Using a Professional Passive Exoskeleton
Not yet recruiting NCT06188312 - Occupational Hazards Among Workers of Superphosphate Fertilizer Factory
Completed NCT03855163 - Effects of Regulatory Tools on Work Environment and Employee Health N/A