Clinical Trials Logo

Clinical Trial Summary

There is limited data regarding sound levels and burden in the pediatric cardiac critical care unit and how this compares with WHO standards. We seek to record this data and correlate sound level with bolus sedation administration, patient delirium scores, and patient heart rate trends. Primary Outcomes - 1 peak sound level in cardiac ICU in decibels - 2 Mean sound level in cardiac ICU in decibels - 3 Compare sound levels to WHO recommendations Secondary Outcomes - 1 To explore patient and unit factors that might influence these levels - 2 To analyze sound levels in post-operative neonates, versus infants, versus children - 3 To analyze patients on invasive versus non-invasine versus no ventilation


Clinical Trial Description

This study aims to measure and average sound levels during hospitalization in the Children's National Pediatric Cardiac Intensive Care Unit (CICU) and investigate any correlation between heightened sound levels, the incidence of delirium, the administration of sedation medications given for agitation, and patient heart rate changes. Recognition of modifiable risk factors, such as sound levels, can lead to the development of preventive strategies to keep sound levels within recommended guidelines and to lessen the amount of sedation medications that are given for agitation. Successful completion of this research will contribute to the development of modifiable environmental factors for the prevention of oversedation and delirium in critically ill children, potentially improving outcomes in a vulnerable patient population. This will be the first study of this nature performed in a large CICU and the first to look at delirium scores and vital sign changes as related to sound levels. Many studies have shown that increased sound levels in hospitals can worsen patient agitation and lead to sleep disturbance and impair rest and healing. The World Health Organization and the Environmental Protection Agency mandate that hospital sound levels not exceed 40-45 decibels dB(A) during the day and 35 dB(A) at night. Previous studies in four European ICUs with adult patients showed that ICUs demonstrated higher than recommended sound levels 50% of the time, with an average sound level of 51 dB(A) over 24 hours and a peak sound level of 85 dB(A). In the only published study on sound levels in a pediatric CICU and their relationship to sedation administration, Guerra et al showed in 2017 that mean levels were over 59dB in both open patient areas as well as single rooms with little variation between day and night levels and that a higher peak and average sound level correlated with more sedation boluses in the subsequent 2 and 5 hours respectively. The association between neurotoxicity and the use of sedatives and analgesia in young infants with congenital heart disease has also been described. In addition, there are appreciable negative hemodynamic effects of oversedation on the pediatric patient recovering from cardiac surgery. For this reason, it is important to investigate the impact that sound levels might have on sedation administration. Along with this, as vital sign changes such as an elevated heart rate can lead to patients receiving additional sedation, it is equally important to study the relationship between patient heart rate and sound level in a cardiac intensive care unit. Delirium is defined as an acute and fluctuating change in attention, thinking, perception, and consciousness secondary to an underlying medical condition. The consequences of delirium have been well studied in the adult critical care population, and include prolonged hospitalization time, difficulty with long-term thinking, increased days of mechanical ventilation, and increased risk of death after discharge from the hospital. In adult intensive care units, delirium screening is routinely performed because of the known consequences of the disease. With the advent of the Cornell Assessment of Pediatric Delirium (CAPD), there is now a rapid and reliable method of screening for delirium in pediatric intensive care units. Since 2018, bedside nurses in the Children's National CICU have been trained to calculate CAP-D scores. This delirium assessment performed once per shift, can be analyzed side-by-side with average sound levels over that same shift to assess for any correlation between these two parameters. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04777695
Study type Observational
Source Children's National Research Institute
Contact
Status Completed
Phase
Start date March 1, 2021
Completion date May 1, 2021

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05035940 - Federal Aviation Administration (FAA) National Sleep Study
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT05207891 - Comparing Pressure Injury Occurrence in Patients Using Two Different Mattresses N/A
Recruiting NCT03754439 - Minimising the Adverse Physiological Effects of Transportation on the Premature Infant
Completed NCT03507855 - The Effect of a Reduced Noise Environment on the Response Time of the Anesthesia Provider N/A
Completed NCT03504553 - The Effect of a Reduced Noise Environment on Induction and Emergence Behavior in Children Undergoing General Anesthesia N/A
Completed NCT05184686 - Effects of Electromagnetic Field and Noise on Resting Electroencephalogram of Health Subjects N/A
Recruiting NCT05774977 - Broadband Sound and Sleep N/A
Withdrawn NCT04822155 - The Social Gradient of Urban Noise Pollution and Its Effect on Pediatric and Adult Health
Recruiting NCT05911204 - Exposure to Intense and Prolonged Noises During Pregnancy
Recruiting NCT04544085 - A Study on Noise Exposure Status and the Effect of Noise Management in Pediatric Intensive Care Unit N/A
Completed NCT05611619 - Low Particle Emission and Low Noise Tyres N/A
Not yet recruiting NCT06294340 - Noise, Oxidative Stress and Cardiovascular System
Completed NCT04638296 - Perceptions On Music And Noise In The OR
Recruiting NCT06260254 - Effects of Railway Vibration on Sleep and Disease N/A
Active, not recruiting NCT05488704 - The Effect of Nonstress Test Device Noise Level on Stress Parameters in Primiparous Pregnant Women
Recruiting NCT04643652 - Effective Strategies to Reduce Noise and Related Distractions N/A
Completed NCT05319262 - Metabolic and Cognitive Consequences of Noise-induced Sleep Disturbance N/A