Newborn Clinical Trial
Official title:
Miller vs Macintosh Size 0 Blades for Tracheal Intubation of Infants Under 1 Month: a Randomized Comparative Study
Miller blades are commonly used in pediatric anesthesia; however, there is less evidence-based information on the superiority of Miller blades in the visualization of the laryngeal inlet to Macintosh blades. The aim of the present study is to compare the glottic views with the size 0 Macintosh and Miller laryngoscope blades above and below the epiglottis.
Status | Not yet recruiting |
Enrollment | 25 |
Est. completion date | December 1, 2017 |
Est. primary completion date | November 1, 2017 |
Accepts healthy volunteers | No |
Gender | All |
Age group | N/A to 30 Days |
Eligibility |
Inclusion Criteria: - ASA I or II patients under 1 month. Exclusion Criteria: - Infants with a history of a difficult airway or diagnosed congenital syndrome, premature infants less than 37 weeks gestational age at birth, and those with acute or chronic pulmonary or neuromuscular diseases will be excluded from the study. |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Istanbul Science University |
DAVENPORT HT, ROSALES JK. Endotracheal intubation of infants and children. Can Anaesth Soc J. 1959 Jan;6(1):65-74. — View Citation
Fiadjoe JE, Gurnaney H, Dalesio N, Sussman E, Zhao H, Zhang X, Stricker PA. A prospective randomized equivalence trial of the GlideScope Cobalt® video laryngoscope to traditional direct laryngoscopy in neonates and infants. Anesthesiology. 2012 Mar;116(3) — View Citation
Jones RM, Jones PL, Gildersleve CD, Hall JE, Harding LJ, Chawathe MS. The Cardiff paediatric laryngoscope blade: a comparison with the Miller size 1 and Macintosh size 2 laryngoscope blades. Anaesthesia. 2004 Oct;59(10):1016-9. — View Citation
Levitan RM, Ochroch EA, Kush S, Shofer FS, Hollander JE. Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale. Acad Emerg Med. 1998 Sep;5(9):919-23. — View Citation
Lingappan K, Arnold JL, Shaw TL, Fernandes CJ, Pammi M. Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates. Cochrane Database Syst Rev. 2015 Feb 18;(2):CD009975. doi: 10.1002/14651858.CD009975.pub2. Review. — View Citation
Ochroch EA, Hollander JE, Kush S, Shofer FS, Levitan RM. Assessment of laryngeal view: percentage of glottic opening score vs Cormack and Lehane grading. Can J Anaesth. 1999 Oct;46(10):987-90. — View Citation
Passi Y, Sathyamoorthy M, Lerman J, Heard C, Marino M. Comparison of the laryngoscopy views with the size 1 Miller and Macintosh laryngoscope blades lifting the epiglottis or the base of the tongue in infants and children <2 yr of age. Br J Anaesth. 2014 — View Citation
Varghese E, Kundu R. Does the Miller blade truly provide a better laryngoscopic view and intubating conditions than the Macintosh blade in small children? Paediatr Anaesth. 2014 Aug;24(8):825-9. doi: 10.1111/pan.12394. Epub 2014 Apr 2. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | POGO scores | the laryngeal views will be photographed during laryngoscopy and will be compared | five months | |
Secondary | complications | any complication will be recorded during tracheal intubation with each device | five months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06350084 -
Effect of Mother's Touch and Nurse's Therapeutic Touch on Pain Level and Crying Time During Heel Blood Collection
|
N/A | |
Not yet recruiting |
NCT04441463 -
Simultaneous Study of the Serum Tryptase Level of the Mother and the Child During Childbirth (TryPla)
|
N/A | |
Not yet recruiting |
NCT04337229 -
Evaluation of Comfort Behavior Levels of Newborns With Artificial Intelligence Techniques
|
N/A | |
Completed |
NCT01732978 -
Are Parents Privileged Listeners Their Baby ?
|
N/A | |
Unknown status |
NCT01029496 -
Immediate VS Delayed Cord Clamping on Newborns
|
Phase 1/Phase 2 | |
Recruiting |
NCT06032494 -
Investigating Changes in Vital Signs in Neonates
|
||
Completed |
NCT03690804 -
Assessment of Autonomic Co-regulation Between Newborn and Parent During Kangaroo Care Sessions in Neonatal Intensive Care Units
|
N/A | |
Completed |
NCT05064683 -
The Effect of Facilitated Tucking and White Noise on Stress and Sleep of Newborns in Nasal CPAP
|
N/A | |
Completed |
NCT04827849 -
Theory of Meleis on Women's Adaptation to Motherhood and Perceptions of Newborn Baby
|
N/A | |
Not yet recruiting |
NCT03630575 -
Study of Psychoactive Substances in Newborns' Hair Whose Mothers Were Treated and Followed at the Nice University Hospital - New Born Hair Study
|
N/A | |
Recruiting |
NCT03109444 -
Normative Radiographic Parameters and Growth Curve of Hips Less Than Six Weeks of Gestational Age Using Ultrasound
|
||
Not yet recruiting |
NCT06053931 -
The Effect of Music on Neonatal Stress, Mother's Breastfeeding Success and Comfort
|
N/A | |
Completed |
NCT04869176 -
Effect of Caffeine on Heart Rate Variability in Newborns
|
N/A | |
Not yet recruiting |
NCT05109481 -
Masks and Visual Preferences in the Newborn
|
||
Completed |
NCT05103800 -
Investigation of the Effect of White Noise Listening on Pain and Comfort During Invasive Interventions in Newborns
|
N/A | |
Completed |
NCT03047967 -
Effects of Prenatal Tobacco Smoke Exposure on Lung Function and Respiratory Epithelium Functionality in Newborns
|
N/A | |
Not yet recruiting |
NCT06418815 -
Concept Map on Toxic Stress in Newborns
|
N/A | |
Completed |
NCT03969459 -
Impact of Exposure to Persistent Organic Pollutants During Pregnancy on the Composition of Breast Milk and Consequences on the Newborn
|
||
Completed |
NCT06352918 -
Peripheral Central Catheter (PICC) Care
|
N/A | |
Completed |
NCT05442619 -
Developing a Portable Therapeutic Baby Nest for Newborns and Evaluation During Venous Blood Collection
|
N/A |