Official title:
Confirmation of Correct Tracheal Tube Placement in Newborn Infants - a Randomized Control Trial
Verified date | March 2017 |
Source | University of Alberta |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Most premature babies have difficulty breathing at birth and need help (resuscitation). The treatment for this is to gently inflate their lungs with a resuscitation device and a facemask. To gently inflate an infant's lungs the clinical team places a breathing tube in the windpipe and blow air into your baby's lung (puffs). With the first puffs the clinical team checks if the breathing tube is correctly placed within the windpipe. The investigators routinely use a detector which checks for exhaled carbon dioxide or the graphical display of waves forms of the infants breathing to check that the breathing tube position. However, the investigators do not know which one (exhaled carbon dioxide or the graphical display of waves forms) is better to check that the breathing tube position is correct and therefore the investigators would like to study them. The purpose of this study is to compare exhaled carbon dioxide detectors (ECO2 group) with the graphical display of waves forms (flow waves group) to provide us with information on how the investigators can help babies who struggle with breathing at birth.
Status | Completed |
Enrollment | 100 |
Est. completion date | October 2014 |
Est. primary completion date | October 2014 |
Accepts healthy volunteers | No |
Gender | All |
Age group | N/A to 120 Days |
Eligibility |
Inclusion Criteria: - All infants (term and preterm) born at The Royal Alexandra Hospital who require endotracheal intubation in the delivery room or neonatal intensive care unit will be recorded. Exclusion Criteria: - Infants will also be excluded if their parents refuse to give consent to this study. |
Country | Name | City | State |
---|---|---|---|
Canada | Royal Alexandra Hospital | Edmonton | Alberta |
Lead Sponsor | Collaborator |
---|---|
University of Alberta |
Canada,
Aziz HF, Martin JB, Moore JJ. The pediatric disposable end-tidal carbon dioxide detector role in endotracheal intubation in newborns. J Perinatol. 1999 Mar;19(2):110-3. — View Citation
Hosono S, Inami I, Fujita H, Minato M, Takahashi S, Mugishima H. A role of end-tidal CO(2) monitoring for assessment of tracheal intubations in very low birth weight infants during neonatal resuscitation at birth. J Perinat Med. 2009;37(1):79-84. doi: 10.1515/JPM.2009.017. — View Citation
Leone TA, Rich W, Finer NN. Neonatal intubation: success of pediatric trainees. J Pediatr. 2005 May;146(5):638-41. — View Citation
O'Donnell CP, Kamlin CO, Davis PG, Morley CJ. Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects. Pediatrics. 2006 Jan;117(1):e16-21. — View Citation
Schmölzer GM, Hooper SB, Crossley KJ, Allison BJ, Morley CJ, Davis PG. Assessment of gas flow waves for endotracheal tube placement in an ovine model of neonatal resuscitation. Resuscitation. 2010 Jun;81(6):737-41. doi: 10.1016/j.resuscitation.2010.02.018. — View Citation
Schmölzer GM, O'Reilly M, Davis PG, Cheung PY, Roehr CC. Confirmation of correct tracheal tube placement in newborn infants. Resuscitation. 2013 Jun;84(6):731-7. doi: 10.1016/j.resuscitation.2012.11.028. Review. — View Citation
Schmölzer GM, Poulton DA, Dawson JA, Kamlin CO, Morley CJ, Davis PG. Assessment of flow waves and colorimetric CO2 detector for endotracheal tube placement during neonatal resuscitation. Resuscitation. 2011 Mar;82(3):307-12. doi: 10.1016/j.resuscitation.2010.11.008. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Using flow waves will increase the percentage of correct tube placement in newborn infants | Flow waves and exhaled Carbon dioxide will be compared using the numbers of inflation needed to identify correct tube placement. We will compare the number of inflation in each group to identify which device can identify correct tube placement faster and more accurately. Outcome will be number of inflation until correct tube placement has been identified. |
within the first 10 inflations |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT00345254 -
Severing Nuchal Cord at the Time of Delivery.
|
Phase 1 | |
Completed |
NCT02405429 -
Temporal Artery Temperature Measurement in Neonates
|
N/A | |
Recruiting |
NCT04004130 -
Ultrasound Imaging of Subarachnoidal Space in Newborn Infants
|
N/A | |
Recruiting |
NCT03957863 -
Study of Erythropoietin in Newborns and Children
|
||
Completed |
NCT01914341 -
Short Term Effects of Live Music in Newborn Infants
|
N/A | |
Active, not recruiting |
NCT02673788 -
Follow-Up Study of Safety of Pneumostem® in Premature Infants With Intraventricular Hemorrhage
|